PubMed Health⌕ Search

Biomedical subjects

Qiping Yu

Publications and source records attributed to Qiping Yu.

6 recordsLinked to original sources

A technique for minimally altering anatomically based subthalamic electrode targeting by microelectrode recording.

OBJECT: Implantation of a subthalamic nucleus (STN) deep brain stimulation (DBS) electrode is increasingly recognized as an effective treatment for advanced Parkinson disease (PD). Despite widespread use of microelectrode recording (MER) to delineate the boundaries of the STN prior to stimulator implantation, it remains unclear to what extent MER improves the clinical efficacy of this procedure. In this report, the authors analyze a series of patients who were treated at one surgical center to determine to what degree final electrode placement was altered, based on readings obtained with MER, from the calculated anatomical target. METHODS: Subthalamic DBS devices were placed bilaterally in nine patients with advanced PD. Frame-based volumetric magnetic resonance images were acquired and then transferred to a stereotactic workstation to determine the anterior and posterior commissure coordinates and plane. The initial anatomical target was 4 mm anterior, 4 mm deep, and 12 mm lateral to the midcommissural point. The MERs defined the STN boundaries along one or more parallel tracks, refining the final electrode placement by comparison of results with illustrations in a stereotactic atlas. In eight of 18 electrodes, the MER results did not prompt an alteration in the anatomically derived target. In another eight placements, MER altered the target by less than 1 mm and two of 18 electrode positions differed by less than 2 mm. The anterior-posterior difference was 0.53 +/- 0.65 mm, whereas the medial-lateral direction differed by 0.25 +/- 0.43 mm. The ventral boundary of the STN defined by MER was 2 +/- 0.72 mm below the calculated target (all values are the means +/- standard deviation). All patients attained clinical improvement, similar to previous reports. CONCLUSIONS: In this series of patients, microelectrode mapping of the STN altered the anatomically based target only slightly. Because it is not clear whether such minor adjustments improve clinical efficacy, a prospective clinical comparison of MER-refined and anatomical targeting may be warranted.

Brain Mapping↗

Subthalamic stimulation for Parkinson disease: determination of electrode location necessary for clinical efficacy.

OBJECT: Deep brain stimulation (DBS) of the subthalamic nucleus (STN) performed using intraoperative microelectrode recording (MER) to adjust electrode placement has become a widely used treatment for patients with advanced Parkinson disease (PD). Few studies have been conducted to examine the location of implanted electrodes relative to the intended target, and even fewer have been undertaken to investigate the degree to which variations in the location of these electrodes impacts their clinical efficacy. This study was performed to examine these issues. METHODS: The authors located 52 bilaterally implanted DBS electrode tips on postoperative magnetic resonance (MR) images obtained in 26 consecutive patients. Postoperative and preoperative planning MR images were merged to determine the DBS electrode tip coordinates relative to the midcommissural point. Surgical records listed the intended target coordinates for each DBS electrode tip. Clinical outcome assessment included the Unified PD Rating Scale (UPDRS) motor score at 1 year, standardized questionnaires, and routine follow-up visits. The mean difference between electrode tip location and intended target for all 52 electrodes was less than 2 mm in all axes. Only one electrode was farther than 3 mm from the intended target, and this was the only electrode that had to be replaced due to lack of clinical efficacy (lack of tremor suppression); its reimplantation 4 mm more medially provided excellent tremor control. High correlation coefficients indicate that the MR imaging analysis accurately determined the anatomical location of the electrode tips. Blinded videotape reviews of UPDRS motor scores comparing effects of stimulation in patients who were "on" and "off" medication identified subgroups in whom there was minimal and maximal stimulation response. Patients in these subgroups had no differences between the MR imaging-determined actual electrode tip location and its intended location. Similarly, improvements of dyskinesias and severity of symptoms encountered during the wearing-off period for the drug did not correlate with variations of electrode tip location. CONCLUSIONS: The findings in this study lead the authors to suggest that a DBS electrode placed anywhere within a 6-mm-diameter cylinder centered at the presumed middle of the STN (based on stereotactic atlas coordinates) provides similar clinical efficacy. Future studies may be warranted to evaluate prospectively the degree to which MER modification of the anatomically and/or image-determined target improves clinical efficacy of DBS electrodes.

Adult↗

Microelectrode recording-determined subthalamic nucleus length not predictive of stimulation-induced side effects.

OBJECT: Deep brain stimulation (DBS) of the subthalamic nucleus (STN) has become a popular treatment for patients with medically refractory Parkinson disease. Many surgeons believe that microelectrode recording (MER) during DBS electrode implantation is needed to optimize placement, whereas stimulation-induced side effects such as paresthesias, dystonic contractions, dyskinesias, and ocular motor signs that become apparent postoperatively may be an indicator of the proximity of the electrode to various boundaries of the STN. This study was performed to evaluate the relationship between mapping of the STN by using MER and postoperative stimulation-induced side effects. METHODS: Eighty-two electrodes implanted in 75 patients between March 1999 and March 2003 were retrospectively examined to evaluate the length of the STN defined by MER, and the number of and threshold for postoperative stimulation-induced side effects. Electrodes were typically tested with increasing stimulation amplitudes (maximum 6 V) by using a monopolar array. The 82 electrodes were associated with 97 stimulation-induced side effects. The mean time between surgery and testing stimulation-induced side effects was 3.9 months. Statistical analysis (two-tailed t-test) revealed no significant difference in the number of stimulation-induced side effects (or the mean threshold for paresthesias, the most common side effect) for electrodes associated with an STN length less than 4.5 mm (13 electrodes) compared with those associated with an STN greater than or equal to 4.5 mm (69 electrodes, p = 0.616). For every electrode, the target adjustment based on MER results was within 2 mm of the image-planned target (usually 1 mm anterior). In the x axis (medial-lateral orientation), there was no systematic difference in adjustments made for the electrodes associated with the shorter compared with the longer STN lengths. In the y axis (anterior-posterior orientation), there was a very small statistically significant difference in the mean adjustment (0.4 mm) between the two groups. CONCLUSIONS: Analysis of these results suggests that a shorter MER-determined STN length alone does not reliably predict the incidence of stimulation-induced side effects.

Chi-Square Distribution↗

Psychogenic tremor disorders identified using tree-based statistical algorithms and quantitative tremor analysis.

Detecting psychogenic tremors (PsychT) is often challenging. As there are no laboratory investigations or imaging techniques that can confirm the diagnosis, PsychT is identified on a clinical basis. We present a tree-based statistical algorithm derived from quantitative computerized tremor recordings as a novel method to help in the recognition of PsychT. The goal of this study was to show that objective data from computerized tremor recordings, when processed through a tree-based statistical algorithm, can be used to determine whether a patient can be classified as having PsychT.

Adult↗

Reaction time and movement time after embryonic cell implantation in Parkinson disease.

BACKGROUND: Embryonic nigral cell implants are a novel treatment for Parkinson disease (PD). Reaction time (RT) and movement time (MT) analysis, validated quantitative measures of premovement neural processing and motor execution, can be used as objective physiological markers of motor performance in PD. OBJECTIVES: To gauge the change in motor performance in patients with PD who received implants, and to determine whether the physiological findings correlate with clinical outcome measures after transplantation. DESIGN: Double-blind, placebo-controlled trial. Patients Forty patients with levodopa-responsive, Hoehn and Yahr stage III or greater PD. INTERVENTIONS: Random assignment to embryonic tissue implants or placebo (sham) operation. MAIN OUTCOME MEASURES: Combined RT + MT scores measured preoperatively and at 4 and 12 months postoperatively in the "off" state. RESULTS: The difference in mean RT + MT scores between the sham and implant groups was statistically significant (P =.005) and was greatest in those 60 years or older (P =.003). Changes correlated with Unified Parkinson's Disease Rating Scale off scores at 4 (r = 0.87, P =.001) and 12 (r = 0.75, P =.01) months in those younger than 60 years. There was a significant deterioration in the sham surgery group at 12 months (P =.03) that was thought to be due to worsening in subjects 60 years and older (P<.001). CONCLUSIONS: The physiological measures detected significant changes in patients undergoing embryonic nigral cell implants and correlated directly with clinical outcome measures. Comprehensive analyses of RT paradigms can document subtle changes in motor performance over time, making them useful outcome measures in therapeutic trials of PD. These findings support further research into nigral cell implantation for PD.

Adult↗

Implantation of bilateral deep brain stimulators in patients with Parkinson disease and preexisting cardiac pacemakers. Report of two cases.

Deep brain stimulation (DBS) has become an important modality in the treatment of refractory Parkinson disease (PD). In patients with comorbid arrhythmias requiring cardiac pacemakers, DBS therapy is complicated by concerns over a possible electrical interaction between the devices (or with device programming) and the inability to use magnetic resonance imaging guidance for implantation. The authors report two cases of PD in which patients with preexisting cardiac pacemakers underwent successful implantation of bilateral DBS electrodes in the subthalamic nucleus (STN). Each patient underwent computerized tomography-guided stereotactic frame-based placement of DBS electrodes with microelectrode recording. Both extension wires were passed from the right side of the head and neck (contralateral to the pacemaker) to place the cranial pulse generators subcutaneously in the left and right abdomen. The cranial pulse generators were placed farther than 6 in from the cardiac pacemaker and from each other to decrease the chance of interference between the devices during telemetry reprogramming. Postoperative management involved brain stimulator programming sessions with simultaneous cardiological monitoring of pacemaker function and cardiac rhythm. No interference was noted at any time, and proper pacemaker function was maintained throughout the follow-up period. With bilateral STN stimulation, both patients experienced a dramatic improvement in their PD symptoms, including elimination of dyskinesias, reduction of "off" severity, and increase of "on" duration. With some modifications of implantation strategy, two patients with cardiac pacemakers were successfully treated with bilateral DBS STN therapy for refractory PD. To our knowledge, this is the first report on patients with cardiac pacemakers undergoing brain stimulator implantation.

Aged↗