PubMed HealthSearch

Biomedical subjects

R A Denham

Publications and source records attributed to R A Denham.

4 recordsLinked to original sources

Coronal alignment after total knee replacement.

Maquet's line passes from the centre of the femoral head to the centre of the body of the talus. The distance of this line from the centre of the knee on a long-leg radiograph provides the most accurate measure of coronal alignment. Malalignment causes abnormal forces which may lead to loosening after knee replacement. We report a series of 115 Denham knee replacements performed between 1976 and 1981 using the earliest design of components, inserted with intramedullary guide rods. Patients were assessed clinically and long-leg standing radiographs were taken before operation, soon after surgery and up to 12 years later. In two-thirds of the knees (68%) Maquet's line passed through the middle third of the prosthesis on postoperative films and the incidence of subsequent loosening was 3%. When Maquet's line was medial or lateral to this, an error of approximately +/- 3 degrees, the incidence of loosening at a median period of eight years was 24%. This difference is highly significant (p = 0.001). Accurate coronal alignment appears to be an important factor in prevention of loosening. Means of improving the accuracy of alignment and of measuring it on long-leg radiographs are discussed.

Adult

The Portsmouth method of external fixation of complicated tibial fractures.

A New method of external fixation for complicated fractures of the tibia is described. The use of acrylic cement to secure the tibial transfixing pins to the external bar and the ability to apply compression across the fracture site are the salient features of this technique, which is simple to use and inexpensive.

Bone Nails

Mechanics of the knee and problems in reconstructive surgery.

Static force transmission at the knee is analysed using measurements from radiographs showing the position of the line of body weight and also the bones of the knee in their correct orientation during function. With this technique it is possible to suggest values for a variety of forces acting at the knee. During function the degree of knee flexion is not as important as the angle that the thigh makes with the vertical. The tension in the extensor mechanism is not the same above and below the patella. Failure to recognise these two features results in fundamental errors. The patella, the effects of patellectomy and of forward displacement of the attachment of the patellar ligament are discussed. The importance of the transmission of force in the coronal plane is emphasised with particular reference to total knee replacement. It is suggested that small errors of geometry, as seen in the anteroposterior radiograph, can produce large changes of load.

Biomechanical Phenomena