Liposome flow injection immunoassay: model calculations of competitive immunoreactions involving univalent and multivalent ligands.

The use of liposomes as detectable reagents in solid-phase immunoassays has been explored in a flow injection immunoanalysis (FIIA) system. Model calculations are presented for FIIA based on the competitive binding of univalent analyte and multivalent liposomes to immobilized antibodies. Parameters such as binding constants, concentrations of liposomes and antibody, and steric hindrance are considered for their relative effects on detectable liposome signal response to analyte concentrations. Qualitative comparisons of the model with the experimental data are made.

Flow Injection Analysis

Immobilization of binding proteins on nonporous supports. Comparison of protein loading, activity, and stability.

Four different nonporous particulate materials, nylon, polystyrene, soda-lime silicate glass, and fused silica glass, have been evaluated for their appropriateness as immobilization supports for immunoglobulins. A method of protein quantitation that is usually applied to solutions, the bicinchoninic acid (BCA) assay, was used successfully to directly measure ng amounts of protein immobilized on the supports. Two proteins, a monoclonal antibody to theophylline and the biotin binding protein avidin, were studied. Radioactive theophylline and radioactive biotin were used to measure the activity of the immobilized protein. Ligand binding capacity per mm2 of support was measured as a function of amount of protein immobilized. By measuring both the amount of protein immobilized and its ligand binding capacity, we have determined that antitheophylline antibody adsorbed on polystyrene balls loses almost 90% of its binding activity after 65 h, although little protein is lost from the balls over this time. Avidin retains nearly full activity for biotin on polystyrene. The binding activity of biotinyl-antibody conjugate immobilized on avidin-adsorbed polystyrene is stable, even when stored for over 22 wk. Antibody covalently immobilized on soda-lime silicate glass beads retains its binding activity over long-term storage, although only 0.1 mol of 3H-theophylline bind per mol of immobilized antibody. Using fused silica glass particles as the solid support, the same antibody binds approx 0.6 mol of ligand per mol of immobilized antibody protein. The structural "softness" of the immunoglobulin requires that interaction with the surface be prevented in order to maintain activity.

Adsorption

Liposome flow injection immunoassay: implications for sensitivity, dynamic range, and antibody regeneration.

We have developed a liposome-based flow injection immunoassay (FIIA) system for quantitation of a clinical analyte, theophylline. With very minor changes in assay format, this procedure can also be used for the quantitation of anti-theophylline. Automated sequential analyses were performed at room temperature with picomole sensitivity and a day-to-day coefficient of variation of less than 5% for aqueous solutions. The system components include liposomes that contain fluorophores in their aqueous centers and an immobilized-antibody reactor column. The immunoreactor was regenerated hundreds of times over 3 months of continuous use with no measurable loss of antibody activity. The two assay formats studied produced distinct dynamic ranges for their respective analytes. The special advantages of using flow injection analysis for immunoassays and of using liposomes in FIIA are discussed.

Antibodies

IFCC document stage 3, draft 1, dated 1989 02 01. An approved IFCC recommendation. IFCC method (1988) for tonometry of blood: reference materials for pCO2 and pO2. International Federation of Clinical Chemistry Scientific Division. Committee on pH, Blood Gases and Electrolytes.

A reference method for tonometry of blood is described. The document covers the theory of tonometry, the materials and equipment needed, and essential aspects of the tonometry procedure for blood. The partial pressures of oxygen and carbon dioxide in tonometered blood are accurately known and therefore this blood is recommended for assessing the accuracy of blood gas analyzers. Tonometry of blood samples from patients may also be used in the determination of acid-base quantities and hemoglobin-oxygen affinity, e.g. p50.

Blood Gas Analysis

Generic liposome reagent for immunoassays.

We have derivatized liposomes with antibodies by using avidin to crosslink biotinylated phospholipid molecules in the liposome membranes with biotinylated antibody molecules. A comparison of the biotin binding activity of avidin in solution and avidin associated with liposomes shows that avidin bound to biotinylated phospholipid in liposome membranes retains full binding activity for additional biotin molecules. Changes in the fluorescence spectrum of avidin have been used to characterize the binding capacity of avidin for biotin in solution, and change in intensity of light scattered due to aggregation of liposomes was used to measure the biotin binding activity of avidin associated with liposomes. Relative amounts of the biotinylated phospholipid, avidin, and biotinylated antibody have been optimized to produce stable liposomes which are derivatized with up to 1.7 nmol of antibody/mumol of lipid. These derivatized liposomes are highly reactive to immunospecific aggregation in the presence of multivalent antigen. A linear increase in light scattering was recorded between 1 and 10 pmol of antigen. This work shows that liposomes containing biotinylated phospholipid can be a successful generic reagent for immunoassays.

Antibodies

International Federation of Clinical Chemistry (IFCC), Scientific Division. Committee on pH. Blood Gases and Electrolytes. IFCC method (1988) for tonometry of blood: reference materials for pCO2 and pO2.

A reference method for tonometry of blood is described. The document covers the theory of tonometry, the materials and equipment needed, and essential aspects of the tonometry procedure for blood. The partial pressures of oxygen and carbon dioxide in tonometered blood are accurately known and therefore this blood is recommended for assessing the accuracy of blood gas analyzers. Tonometry of blood samples from patients may also be used in the determination of acid-base quantities and hemoglobin-oxygen affinity e.g. p50.

Blood Gas Analysis