Rapidly polymerized collagen gel as a smoothing agent in excimer laser photoablation.

BACKGROUND: Excimer laser photoablation effectively and precisely removes corneal tissue but may not smooth irregularities on the anterior corneal surface. An even surface might be obtained by applying a smoothing substance that fills in irregularities and ablates at the same rate as corneal tissue. Evaluation of collagen gel as a smoothing agent is reported. METHODS: Pure, type I collagen solutions were prepared to remain soluble at physiological pH and to spontaneously gel when exposed to cationic buffers. Collagen gels were formed on the surface of enucleated porcine corneas and on human donor corneas and exposed to varying pulses of 193-nanometer excimer laser energy. Effects of collagen gel on ablation depth, corneal surface smoothness, and smoothing of roughened cornea were evaluated by examining scanning electron micrographs of control and treated specimens. RESULTS: Collagen gels formed from 5 mg/ml collagen solutions dramatically altered the depth of photoablation. Photoablation of roughened cornea with collagen gels produced smooth corneal surfaces, whereas control eyes remained roughened and irregular. The smoothness of photoablated cornea surfaces improved when collagen gels were applied prior to photoablation. CONCLUSIONS: The rapidly gelling collagen solution appears to exhibit the functional properties required for an effective smoothing agent for excimer laser photoablation. The substance has low viscosity when applied to the corneal surface and forms a rigid gel when exposed to cationic buffer solution. In addition, the concentration of the collagen gel can be adjusted to provide different ablation rates.

Animals↗

Healing after photorefractive keratectomy in cat eyes with a scanning mid-infrared Nd:YAG pumped optical parametric oscillator laser.

PURPOSE: To evaluate the healing characteristics of cat corneas treated with a new scanning mid-infrared laser system. METHODS: Six adult cats were treated with 6-mm diameter photorefractive keratectomy (PRK) corrections. One eye in each animal was untreated as a control and the other was treated with either a -3.00 or -6.00 diopter ablation. The laser was a new Nd:YAG pumped optical parametric oscillator laser at 2.94 microm with a new scanning delivery system. The pulse width was 7 nanoseconds, the repetition rate was 10 Hz, the size of the laser spot on the eye was 1.0 mm, and the fluence was 150 mJ/cm2. Healing of the cat corneas was followed for 4 months. Slit-lamp and corneal topography evaluations were done at each follow-up examination. Histology was performed at the end of the study. RESULTS: The corneal epithelium healed within 1 week. There was no stromal haze in any eye after the epithelium healed. After the first 2 weeks, slit-lamp examination could not identify which eye was treated. Corneal topography showed corneal flattening. Light microscopy at 4 months revealed normal epithelium and increased keratocyte density in the anterior third of the cornea. Electron microscopy showed discontinuities in the basement membrane and hemidesmosomes. The deep stroma and endothelium were normal. CONCLUSIONS: Cat corneas treated with the new optical parametric oscillator laser healed normally with no adverse effects. Increased keratocyte activity in the anterior stroma was the only noticeable response besides the flattening shown by topography.

Animals↗

Histological comparison of corneal ablation with Er:YAG laser, Nd:YAG optical parametric oscillator, and excimer laser.

PURPOSE: To use histological techniques to assess and compare the ablation depth, local damage, and surface quality of corneal ablations by a Q-switched Er:YAG laser, an optical parametric oscillator laser at 2.94 microm, a long pulse Er:YAG laser, and a 193-nm excimer laser. METHODS: Human cadaver eyes and in vivo cat eyes were treated with a 6.0-mm diameter, 30-microm-deep phototherapeutic keratectomy ablation and a 6.0-mm diameter, -5.00-D photorefractive keratectomy ablation. Human cadaver eyes were also treated with a 5.0-mm diameter, -5.00-D laser in situ keratomileusis (LASIK) ablation. Fluences and pulse widths used were 200 mJ/cm2 and 70 ns for the Q-switched Er:YAG, 150 mJ/cm2 and 7 ns for the optical parametric oscillator laser (OPO), 500 mJ/cm2 and 50 microseconds for the long pulse Er:YAG, and 160 mj/cm2 and 20 ns for the excimer laser. In the ablation rate study, 12 porcine eyes were ablated by the OPO laser with a range of layers and at different fluences ranging from 60 to 150 mJ/cm2, all using a 1.5-mm spot on the eye. The ablation depth of these acute ablations was evaluated by light microscopy examination. RESULTS: In the acute damage study, light microscopy showed a thin surface layer in all samples with minimal thermal damage except on the long pulse Er:YAG corneas. Transmission electron microscopy revealed less than 0.3-microm surface damage for all specimens of both the optical parametric oscillator and the excimer laser samples with no evidence of collagen shrinkage. Transmission electron microscopy showed damage layers of 0.5 to 3 microm for Q-switched Er:YAG and 3 to 10 microm for long pulse Er:YAG. Scanning electron microscopy showed smooth surfaces in all eyes, although the excimer was the roughest. In the porcine eye study, ablations were produced in both PTK and PRK modes with the ablation rate per layer increasing with the fluence. At 120 mJ/cm2, the average ablation rate was 1.9 microm per layer. CONCLUSIONS: The histology from the short pulse mid-infrared optical parametric oscillator laser at 2.94 microm was comparable to the 193-nm excimer with a smooth, damage-free, ablation zone when performing PRK and LASIK.

Algorithms↗

Excimer laser photorefractive keratectomy for myopia: six-month results.

Six eyes of six patients with myopia between -4.00 and -8.00 diopters underwent 193 nm Argon/fluoride excimer laser photorefractive keratectomy as part of a Phase II-A FDA Study. Six months after surgery, four of the six eyes had a spherical equivalent refraction within +/- 1.00 D; five eyes saw 22/30 or better without correction. All corneas demonstrated a faint reticulated subepithelial haze most visible by sclerotic scatter illumination. There were no episodes of delayed epithelial healing or recurrent erosions, and patients had no loss of contrast sensitivity, visual acuity under glare testing, or corneal sensation at the 3-month or 6-month visit. In this limited clinical trial, the excimer laser was capable of changing the refractive power of the cornea for correction of myopia. Long-term follow up of these patients will be necessary to determine the safety and efficacy of the procedure.

Adult↗