Routine quality control tests for film-screen mammographic systems with automatic exposure control.

Quality control of the contrast and density of mammograms is of extreme importance not only because of patient dose considerations but also because of the need to monitor changes in the breast over extended periods of time. A phantom and test technique has been developed and used at two institutions for monitoring the ability of mammographic generators and phototiming systems to provide consistent contrast and density. The phantom consists of a solid acrylic block and an embedded aluminum step wedge designed specially for low kVp use. Optical densities of various portions of the phantom are used to determine constancy of density and contrast. By minimizing fluctuations due to processing and film handling, normal variations were reduced enough to determine changes in contrast and density due to generator and phototimer changes equivalent to those monitored in processor quality control programs. The data have been correlated with changes in processor function. Changes in density and contrast values have also been related to phototimer malfunction and reduced image quality.

Autoanalysis↗

Fluoroscopy: recording of fluoroscopic images and automatic exposure control.

Some means of recording images is a necessary part of most fluoroscopic systems. Several methods are available for recording images during fluoroscopy. Screen-film recording methods such as use of spot film devices and automatic film changers provide high-spatial-resolution images. Recording images by using the image intensifier (fluorography) provides film or digital images at relatively lower doses but with poorer spatial resolution. Digitally recorded images have better contrast resolution than analog images but lower spatial resolution and represent a compromise between dose and image quality. Motion picture (cine fluorographic) recording requires extremely high dose rates compared with those of lower-resolution videotape recording of motion. Recording systems in fluoroscopy require automatic exposure control for optimum image quality. The same feedback system used to control fluorographic exposures can be used to control exposure rates during fluoroscopy as well. Automatic brightness control maintains intensifier exposure rates on the basis of subject thickness by adjusting various technique factors. The type of control mechanism depends on the imaging task and the complexity (age and cost) of the equipment. The operator can choose between better image quality (higher contrast) or lower radiation dose.

Fluoroscopy↗