Autonomic blockade in chronic Chagas' heart disease. Heart rate response at rest and during upright exercise. A preliminary report.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to R A Godoy.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Transesophageal recording of heart potentials is a fully accepted procedure for the electrical study of the heart. However, the intraesophageal ECG could be explored even better by using multipolar catheter electrodes and by considering various characteristics of the tracing such as amplitude, frequency and velocity. The authors describe their experience with the use of these electrodes and recording characteristics applied to the field of investigation and diagnosis of the electrical activity of supraventricular region. This objective can also by achieved by constructing esophagus-thoracic wall bipolar derivations.
Considering that catheterization of the esophagus is a relatively easy procedure, we studied the electrical transesophageal atrial stimulation in ninety patients (age range 15 to 75 years (mean 42 +/- 9 years). A multipolar electrode catheter was introduced through the nose into the esophagus of each patient and fixed in position at a site where the simultaneous recording of intraesophageal unipolar electrocardiographic derivations showed the greatest P wave potentials. Electrical atrial capture through the esophagus was obtained at frequency values higher than that of the heart, with lower voltages needed for atrial stimulation at the site in which the unipolar recording of the intraesophageal P wave was of highest amplitude. The difference of potential used was between 6 and 30 volts, with the highest values corresponding to patients with megaesophagus, whereas values below 15 volts were tolerated without major discomfort. Electric pulses of more than 10 ms duration did not significantly reduce the intensity of electric current needed to produce the atrial command. The stimulation bipole (area to be stimulated per pole, 0.72 cm2) had an interpolar distance of 22 or 30 mm, our overall experience showing that distances up to 44 mm did not require higher voltages. No cases of esophageal damage or severe arrhythmia were reported due to stimulation. In the present study, programmed transesophageal stimulation proved to be a good option for the evaluation of sinus node function and for the study and reversal of paroxysmal supraventricular tachycardia attacks by a reentry mechanism, representing in some cases an alternative approach for the study of atrioventricular conduction.