PubMed Health⌕ Search

Biomedical subjects

R A Kleinerman

Publications and source records attributed to R A Kleinerman.

At least 19 recordsLinked to original sources

Retrospective assessment of radiation exposure using biological dosimetry: chromosome painting, electron paramagnetic resonance and the glycophorin a mutation assay.

Biological monitoring of dose can contribute important, independent estimates of cumulative radiation exposure in epidemiological studies, especially in studies in which the physical dosimetry is lacking. Three biodosimeters that have been used in epidemiological studies to estimate past radiation exposure from external sources will be highlighted: chromosome painting or FISH (fluorescence in situ hybridization), the glycophorin A somatic mutation assay (GPA), and electron paramagnetic resonance (EPR) with teeth. All three biodosimeters have been applied to A-bomb survivors, Chernobyl clean-up workers, and radiation workers. Each biodosimeter has unique advantages and limitations depending upon the level and type of radiation exposure. Chromosome painting has been the most widely applied biodosimeter in epidemiological studies of past radiation exposure, and results of these studies provide evidence that dose-related translocations persist for decades. EPR tooth dosimetry has been used to validate dose models of acute and chronic radiation exposure, although the present requirement of extracted teeth has been a disadvantage. GPA has been correlated with physically based radiation dose after high-dose, acute exposures but not after low-dose, chronic exposures. Interindividual variability appears to be a limitation for both chromosome painting and GPA. Both of these techniques can be used to estimate the level of past radiation exposure to a population, whereas EPR can provide individual dose estimates of past exposure. This paper will review each of these three biodosimeters and compare their application in selected epidemiological studies.

Biological Assay↗

Adjusting lung cancer risks for temporal and spatial variations in radon concentration in dwellings in Gansu Province, China.

Our recent study in Gansu Province, China reported an increasing risk of lung cancer with increasing residential radon concentration that was consistent with previous pooled analyses and with meta-analyses of other residential studies (Wang et al., Am. J. Epidemiol. 155, 554-564, 2002). Dosimetry used current radon measurements (1-year track-etch detectors) in homes to characterize concentrations for the previous 30 years, resulting in uncertainties in exposure and possibly reduced estimates of disease risk. We conducted a 3-year substudy in 55 houses to model the temporal and spatial variability in radon levels and to adjust estimates of radon risk. Temporal variation represented the single largest source of uncertainty, suggesting the usefulness of multi-year measurements to assess this variation; however, substantial residual variation remained unexplained. The uncertainty adjustment increased estimates of the excess odds ratio by 50-100%, suggesting that residential radon studies using similar dosimetry may also underestimate radon effects. These results have important implications for risk assessment.

Adult↗

Magnetic fields produced by hand held hair dryers, stereo headsets, home sewing machines, and electric clocks.

A recent epidemiologic study reported associations between leukemia risk in children and their personal use of television (TV) sets, hair dryers, and stereo headsets, and the prenatal use by their mothers of sewing machines. To provide exposure data to aid in the interpretation of these findings, extremely and very low frequency (ELF and VLF) magnetic fields produced by a sample of each type of appliance were characterized in a field study of volunteers conducted in Washington DC and its Maryland suburbs. Questionnaire data regarding children's or mothers' patterns of usage of each type of appliance were also collected. ELF magnetic fields measured 10 cm from the nozzles of hair dryers were elevated over the ambient by a mean factor of 17 when these devices were in use. Fields near headsets being used to listen to music were not distinguishable from ambient levels except at frequencies below and well above 60 Hz and, even then, field levels were < 0.01 microT. Home sewing machines produced ELF magnetic fields that were elevated by a factor of 2.8 over ambient levels at the front surfaces of the lower abdomens of mothers. Estimated mean daily times of usage of hair dryers, stereo headsets, and sewing machines were 2.6, 19, and 17 minutes, respectively. These data and previously published data on TV sets, do not provide a consistent picture of increased (or decreased) leukemia risk in relation to increasing peak or time weighted average (TWA) ELF magnetic field exposure. The data could, however, conceivably be compatible with some more complex biophysical model with unknown properties. Overall, the results of this study provide little evidence supporting the hypothesis that peak or TWA ELF magnetic fields produced by appliances are causally related to the risk of childhood leukemia in children.

Adolescent↗

Static magnetic field measurements in residences in relation to resonance hypotheses of interactions between power-frequency magnetic fields and humans.

Bowman et al. used epidemiologic data to test a model in which subjects were classified as being "in-resonance" or "not-in-resonance" for 60-Hz magnetic-field exposures depending on single static magnetic-field measurements at the centers of their bedrooms. A second paper by Swanson concluded that a single static magnetic-field measurement is insufficient to meaningfully characterize a residential environment. The main objective of this study was to investigate exposure-related questions raised by these two papers in two U.S. data sets, one containing single spot measurements of static magnetic fields at two locations in homes located in eight states, and the other repeated spot measurements (seven times during the course of one year) of the static magnetic fields at the centers of bedrooms and family rooms and on the surfaces of beds in 51 single-family homes in two metropolitan areas. Using Bowman's criterion, bedrooms were first classified as being in-resonance or not-in-resonance based on the average of repeated measurements of the static magnetic field measured on the bed where the presumed important exposure actually occurred. Bedrooms were then classified a second time using single spot measurements taken at the centers of bedrooms, centers of family rooms, or on the surfaces of beds, as would be done in the typical epidemiologic study. The kappa statistics characterizing the degree of concordance between the first (on-bed averages) and second (spot measurements) methods of assessing resonance status were 0.44, 0.33, and 0.67, respectively. This level of misclassification could significantly affect the results of studies involving the determination of resonance status.

Adolescent↗

Previous pulmonary diseases and risk of lung cancer in Gansu Province, China.

BACKGROUND: Although active smoking is well established as the main cause of lung cancer, there is accumulating evidence that history of prior lung diseases may be an independent risk factor for lung cancer. METHODS: A population-based case-control study in Gansu Province, China identified 886 lung cancer cases (656 male, 230 female) diagnosed between January 1994 and April 1998. A standardized interview collected information on a variety of potential risk factors including a history of physician-diagnosed non-malignant lung diseases (pulmonary tuberculosis, chronic bronchitis/emphysema, asthma, pneumonia), age and year in which each condition was first diagnosed, and any therapy or hospitalization received. RESULTS: Pulmonary tuberculosis (odds ratio [OR] = 2.1, 95% CI : 1.4-3.1) and chronic bronchitis/emphysema (OR = 1.4, 95% CI : 1.1-1.8) were associated with increased risk of lung cancer, after adjustment for active smoking and socioeconomic status. The OR for asthma (OR = 1.4, 95% CI : 0.9-2.1) and pneumonia (OR = 1.5, 95% CI : 1.0-2.3) were also elevated. The risk of lung cancer remained significant for pulmonary tuberculosis and chronic bronchitis/emphysema when analysis was limited to the pathologically confirmed cases and self-responders. CONCLUSIONS: This study provides additional evidence that previous pulmonary tuberculosis and chronic bronchitis/emphysema are causally related to lung cancer, although the precise mechanism is still unclear. The results for asthma and pneumonia, while suggestive of a positive association, did not reach the traditional level of statistical significance and should be interpreted with caution.

Adult↗

Household solvent exposures and childhood acute lymphoblastic leukemia.

OBJECTIVES: This study explored the risk of childhood acute lymphoblastic leukemia (ALL) associated with participation by household members in hobbies or other home projects involving organic solvents. METHODS: Participants in this case-control study were 640 subjects with ALL and 640 matched controls. RESULTS: Childhood ALL was associated with frequent (> 4 times/month) exposure to model building (odds ratio [OR] = 1.9; 95% confidence interval [95% CI] = 0.7, 5.8) and artwork using solvents (OR = 4.1; 95% CI = 1.1, 15.1). We also found elevated risk (OR = 1.7; 95% CI = 1.1, 2.7) among children whose mothers lived in homes painted extensively (> 4 rooms) in the year before the children's birth. CONCLUSIONS: In this exploratory study, substantial participation by household members in some common household activities that involve organic solvents was associated with elevated risks of childhood ALL.

Child↗

Lung cancer and environmental tobacco smoke in a non-industrial area of China.

We report results from a population-based case-control study of lung cancer and environmental tobacco smoke (ETS) among never-smokers conducted in 2 rural prefectures of China, including 200 female and 33 male lung cancer cases, and 407 female and 114 male controls, matched on age, sex and prefecture of current residence. The odds ratio (OR) for ever-exposed to ETS was 1.19 (95% CI 0.7-2.0), with a significant trend (p<0.05) with increasing exposure. ORs were 1.00, 1.04, 1.13 and 1.51 for non-exposed, <10, 10-19 and >/=20 pack-years of ETS exposure, respectively. Excess risks were limited to ETS exposures in childhood (</=18 years of age). The OR for ever-exposed to ETS in childhood, adjusting for ETS exposure in adulthood, was 1. 52 (95% CI 1.1-2.2), with a significant trend (p<0.01) with increasing pack-years of childhood exposure, 1.00, 1.43, 1.81 and 2. 95, respectively. After adjustment for ETS in childhood, there was no excess risk from adult ETS exposure. The OR for ever-exposed to ETS in adulthood was 0.90 (95% CI 0.-1.4). These results were not affected by adjustment for type of residential dwelling, type or amount of fuel used, perceived indoor smokiness, or measures of socioeconomic status, or omitting next-of-kin respondents.

Adult↗

Extremely low-frequency magnetic fields and childhood acute lymphoblastic leukemia: an exploratory analysis of alternative exposure metrics.

Data collected by the National Cancer Institute-Children's Cancer Group were utilized to explore various metrics of magnetic field levels and risk of acute lymphoblastic leukemia (ALL) in children. Cases were aged 0-14 years, were diagnosed with ALL during 1989-1993, were registered with the Children's Cancer Group, and resided in one home for at least 70 percent of the 5 years immediately prior to diagnosis. Controls were identified by using random digit dialing and met the same residential requirements. With 30-second ("spot") measurements and components of the 24-hour measurement obtained in the subject's bedroom, metrics evaluated included measures of central tendency, peak exposures, threshold values, and measures of short-term temporal variability. Measures of central tendency and the threshold measures showed good-to-high correlation, but these metrics correlated less well with the others. Small increases in risk (ranging from 1.02 to 1.69 for subjects in the highest exposure category) were associated with some measures of central tendency, but peak exposures, threshold values, measures of short-term variability, and spot measurements demonstrated little association with risk of childhood ALL. In general, risk estimates were slightly higher for the nighttime (10 p.m.-6 a.m.) interval than for the corresponding 24-hour period.

Adolescent↗

Are children living near high-voltage power lines at increased risk of acute lymphoblastic leukemia?

In the National Cancer Institute/Children's Cancer Group case-control study of childhood acute lymphoblastic leukemia (1989-1993), living in a home with a high-voltage wire code was not associated with disease risk. To further investigate risk near power lines, the authors analyzed distance to transmission and three-phase primary distribution lines within 40 m of homes and created an exposure index of distance and strength of multiple power lines (408 case-control pairs). Neither distance nor exposure index was related to risk of childhood acute lymphoblastic leukemia, although both were associated with in-home magnetic field measurements. Residence near high-voltage lines did not increase risk.

Adolescent↗

Children's exposure to magnetic fields produced by U.S. television sets used for viewing programs and playing video games.

Two epidemiologic studies have reported increased risk of childhood leukemia associated with the length of time children watched television (TV) programs or played video games connected to TV sets. To evaluate magnetic field exposures resulting from these activities, the static, ELF, and VLF magnetic fields produced by 72 TV sets used by children to watch TV programs and 34 TV sets used to play video games were characterized in a field study conducted in Washington DC and its Maryland suburbs. The resulting TV-specific magnetic field data were combined with information collected through questionnaires to estimate the magnetic field exposure levels associated with TV watching and video game playing. The geometric means of the ELF and VLF exposure levels so calculated were 0.0091 and 0.0016 microT, respectively, for children watching TV programs and 0.023 and 0.0038 microT, respectively, for children playing video games. Geometric means of ambient ELF and VLF levels with TV sets turned off were 0.10 and 0.0027 microT, respectively. Summed over the ELF frequency range (6-3066 Hz), the exposure levels were small compared to ambient levels. However, in restricted ELF frequency ranges (120 Hz and 606-3066 Hz) and in the VLF band, TV exposure levels were comparable to or larger than normal ambient levels. Even so, the strengths of the 120 Hz or 606-3066 Hz components of TV fields were small relative to the overall ambient levels. Consequently, our results provide little support for a linkage between childhood leukemia and exposure to the ELF magnetic fields produced by TV sets. Our results do suggest that any future research on possible health effects of magnetic fields from television sets might focus on the VLF electric and magnetic fields produced by TV sets because of their enhanced ability relative to ELF fields to induce electric currents.

Adolescent↗

Do confounding or selection factors of residential wiring codes and magnetic fields distort findings of electromagnetic fields studies?

In contrast with several previous studies, our recent large case-control study found little association between childhood acute lymphoblastic leukemia (ALL) and electric-power-line wire codes. Here we examine internal evidence from our study to assess the possibility that selection bias and/or confounding may have affected the findings. We compared the relation between childhood ALL and wire codes and direct measurements of magnetic fields in subjects who participated in all phases of the study with the relation in all subjects, including those who declined to allow access inside the home. We found that the odds ratio for ALL among those living in homes with very high current configurations increased by 23% when 107 "partial participants" were excluded. We found similar, but slightly smaller, increases in the odds ratios when we performed the same comparisons using direct measurements of magnetic fields, excluding subjects who allowed only a measurement outside the front door. "Partial participants" tended to be characterized by lower socioeconomic status than subjects who participated fully, suggesting possible selection bias. We also examined the relation between a large number of potential confounding variables and both proxy and direct measurements of magnetic fields. Univariate adjustment for individual variables changed the odds ratio for ALL by less than 8%, while simultaneous adjustment for several factors reduced the estimate by a maximum of 15%. We conclude that while confounding alone is unlikely to be an important source of bias in our own and previous studies of magnetic fields, selection bias may be more of a concern, particularly in light of the generally low response rates among controls in case-control studies.

Case-Control Studies↗

Residential exposure to magnetic fields: an empirical examination of alternative measurement strategies.

OBJECTIVES: To investigate the impact of measuring a single home then imputing information from another home among subjects who lived in two homes in a subset of the National Cancer Institute/Children's Cancer Group (NCI/CCG) investigation of residential exposure to magnetic fields and risk of childhood leukaemia. METHODS: Each subject's summary time weighted average (TWA) exposure was derived from measurements of two homes, weighted by the fraction of the reference period lived in the residence. The three cost efficient field work strategies examined were measuring: (a) the longer lived in home; (b) the currently lived in home; and (c) the former lived in home. Two different methods were used for imputing the missing values: (a) control mean imputation, (b) status specific mean imputation. The subject's summary exposure to magnetic fields estimated with each approach was compared with the subject's TWA calculated from measurements in both homes. The association between estimated exposure to magnetic fields and the risk of leukaemia under different approaches was examined with unconditional logistic regression analysis. RESULTS: The Pearson correlation coefficient between the two measurements within subjects was 0.31 (p < 10(-4), indicating a lack of independence of measurements. Differences were found between mean exposures in current and former homes of cases, and between longer and shorter lived in homes of controls. All methods with measurements from one of the homes in conjunction with imputation of measurements for the second home led to marked attenuation of risk estimates at the highest exposure category, particularly when measurements from current homes were used and those from former homes were imputed. CONCLUSION: Results argue against attempting to estimate lifetime magnetic field exposure from imputed values derived from current residences to fill in gaps caused by unmeasured residences previously lived in.

Bias↗

Case-control study of childhood acute lymphoblastic leukemia and residential radon exposure.

BACKGROUND: Several ecologic analyses have shown significant positive associations between mean indoor radon concentrations and risk of leukemia at all ages (acute myeloid leukemia and chronic lymphocytic leukemia) and for children (all leukemia, acute myeloid leukemia, and acute lymphoblastic leukemia [ALL]). As part of an age-matched, case-control study of childhood ALL in the United States, we investigated the association between the incidence of ALL in children under age 15 years and indoor radon exposure. METHODS: Radon detectors were placed in current and previous homes of subjects where they resided for 6 months or longer. Children were included in analyses if radon measurements covered 70% or more of the 5-year period prior to diagnosis for case subjects (or from birth for case subjects under age 5 years) and the corresponding reference dates for control subjects. Radon levels could be estimated for 97% of the exposure period for the eligible 505 case subjects and 443 control subjects. RESULTS: Mean radon concentration was lower for case subjects (65.4 becquerels per cubic meter [Bqm(-3)]) than for control subjects (79.1 Bqm(-3)). For categories less than 37, 37-73, 74-147, and 148 or more Bqm(-3) of radon exposure, relative risks based on matched case-control pairs were 1.00, 1.22, 0.82, and 1.02, respectively, and were similar to results from an unmatched analysis. There was no association between ALL and radon exposure within subgroups defined by categories of age, income, birth order, birth weight, sex, type of residence, magnetic field exposure, parental age at the subject's birth, parental occupation, or parental smoking habits. CONCLUSIONS: In contrast to prior ecologic studies, the results from this analytic study provide no evidence for an association between indoor radon exposure and childhood ALL.

Carcinogens, Environmental↗

Residential wire codes: reproducibility and relation with measured magnetic fields.

OBJECTIVES: To investigate the reproducibility of wire codes to characterise residential power line configurations and to determine the extent to which wire codes provide a proxy measure of residential magnetic field strength in a case-control study of childhood leukaemia conducted in nine states within the United States. METHODS: Misclassification of wire codes was assessed with independent measurements by two technicians for 187 residences. The association between categories of wire code and measured level of magnetic field was evaluated in 858 residences with both a wire code measurement and a 24 hour measurement of the magnetic field in the bedroom. The strength of the association between category of wire code and risk of leukaemia was examined in two regions with different average levels of magnetic field in homes with high categories of wire code. RESULTS: The reproducibility of any of three different classifications of wire codes was excellent (kappa > or = 0.89). Mean and median magnetic fields, and the percentage of homes with high magnetic fields increased with increasing category for each of the wire code classification schemes. The size of the odds ratios for risk of leukaemia and high categories of wire code did not reflect the mean levels of the magnetic field in those categories in two study regions. CONCLUSION: Misclassification of categories of wire code is not a major source of bias in the study. Wire codes provide a proxy measure of exposure to residential magnetic fields. If magnetic fields were a risk factor for leukaemia, however, there would be some attenuation of risk estimates based on wire codes because of misclassification of exposure to magnetic fields at both extremes of the wire code range. The lack of an association between high categories of wire code and risk of leukaemia cannot be explained by a failure of the wire code classification schemes to estimate exposure to magnetic fields in the study area.

Bias↗

Association between childhood acute lymphoblastic leukemia and use of electrical appliances during pregnancy and childhood.

As part of a comprehensive study of residential magnetic field exposure in nine midwestern and mid-Atlantic states, we evaluated the use of appliances by 640 patients with acute lymphoblastic leukemia, 0-14 years of age, diagnosed between 1989 and 1993, and 640 matched control children. Mothers were interviewed regarding use of electrical appliances during their pregnancy with the subject and the child's postnatal use. The risk of acute lymphoblastic leukemia was elevated in children whose mothers reported use of an electric blanket or mattress pad during pregnancy [odds ratio (OR) = 1.59; 95% confidence interval (CI) = 1.11-2.29] but was reduced for use of sewing machines during pregnancy (OR = 0.76; 95% CI = 0.59-0.98). The risk of acute lymphoblastic leukemia was increased with children's use of electric blankets or mattress pads (OR = 2.75; 95% CI = 1.52-4.98) and three other electrical appliances (hair dryers, video machines in arcades, and video games connected to a television), but the patterns of risk for duration in years of use and frequency of use were inconsistent for most appliances used by children. Risks rose with increasing number of hours per day children spent watching television, but risks were similar regardless of the usual distance from the television. The inconsistency in the dose-response patterns for many appliances, reporting and selection bias, and the lack of an effect for measured 60 Hertz magnetic fields or wire codes in our companion study must be considered before ascribing these associations to exposures from magnetic fields.

Case-Control Studies↗

Cancer incidence after retinoblastoma. Radiation dose and sarcoma risk.

CONTEXT: There is a substantial risk of a second cancer for persons with hereditary retinoblastoma, which is enhanced by radiotherapy. OBJECTIVE: To examine long-term risk of new primary cancers in survivors of childhood retinoblastoma and quantify the role of radiotherapy in sarcoma development. DESIGN: Cohort incidence study of patients with retinoblastoma followed for a median of 20 years, and nested case-control study of a radiation dose-response relationship for bone and soft tissue sarcomas. SETTING/PARTICIPANTS: A total of 1604 patients with retinoblastoma who survived at least 1 year after diagnosis, identified from hospital records in Massachusetts and New York during 1914 to 1984. RESULTS: Incidence of subsequent cancers was statistically significantly elevated only in the 961 patients with hereditary retinoblastoma, in whom 190 cancers were diagnosed, vs 6.3 expected in the general population (relative risk [RR], 30 [95% confidence interval, 26-47]). Cumulative incidence (+/-SE) of a second cancer at 50 years after diagnosis was 51.0% (+/-6.2%) for hereditary retinoblastoma, and 5.0% (+/-3.0%) for nonhereditary retinoblastoma. All 114 sarcomas of diverse histologic types occurred in patients with hereditary retinoblastoma. For soft tissue sarcomas, the RRs showed a stepwise increase at all dose categories, and were statistically significant at 10 to 29.9 Gy and 30 to 59.9 Gy. A radiation risk for all sarcomas combined was evident at doses above 5 Gy, rising to 10.7-fold at doses of 60 Gy or greater (P<.05). CONCLUSIONS: Genetic predisposition has a substantial impact on risk of subsequent cancers in retinoblastoma patients, which is further increased by radiation treatment. A radiation dose-response relationship is demonstrated for all sarcomas and, for the first time in humans, for soft tissue sarcomas. Retinoblastoma patients should be examined for new cancers and followed into later life to determine whether their extraordinary cancer risk extends to common cancers of adulthood.

Adolescent↗