PubMed HealthSearch

Biomedical subjects

R A Laurence

Publications and source records attributed to R A Laurence.

6 recordsLinked to original sources

Quality of hemodialysis water: a 7-year multicenter study.

Since dialysis was introduced 30 years ago, constant progress in technology permitted shortening the length of hemodialysis (HD) sessions. Through growing concerns about the inadequacy of tap water for dialysate production, hospitals soon opted for water treatment systems dedicated to HD. Nonetheless, persistent bacterial contamination and the occurrence of pyrogenic reactions were reported in some HD centers. Several factors contributing to this situation were identified. After the introduction of highly permeable synthetic membranes in the late 1970s, microbiologic problems reappeared. Thus, in 1977, the Centers for Disease Control and Prevention (CDC) issued proposed guidelines for HD water quality, followed in 1981 by an American National Standard for HD water, issued by the Association for the Advancement of Medical Instrumentation (AAMI). This Standard was also followed in Canada up to 1986, at which time a National Standard for Canada was released by the Canadian Standards Association (CSA). This prompted the Laboratoire de santé publique du Québec (LSPQ) to implement in the Province of Québec a voluntary HD water quality monitoring program. All 36 HD centers in the Province agreed to participate. The program was launched in February 1987. Water was sampled monthly for bacteria over a 7-year period (February 1987 to January 1994), and every 3 months for pyrogen and chemicals. Participation was more than 95%. Bacteriologic samples were processed in duplicate on heterotrophic plate count agar by the pour plate technique. Incubation was for 48 +/- 3 hours at 35 +/- 0.5 degrees C, and the colonies were counted on a Quebec colony counter (New Brunswick Scientific Co, New Brunswick, NJ). Pyrogen determinations were made using the limulus amebocyte lysate (LAL) test on 1:20 sample dilution by the gel-clot method. Chemical elements were measured by inductively coupled plasma emission, graphite furnace absorption, conductivity, ultraviolet light absorption, or colorimetry. Only fully treated HD water samples were selected from the 11,000 water samples received. Of the 5,820 samples retained for this study, 3,547 were for bacterial, 1,112 for pyrogen, and 1,161 for chemical analyses. Overall compliance to the CSA Standard was 70% for bacteria, 56% for pyrogen, and 86% for chemistry. The performance of different types of water treatments were compared and discussed; the best overall compliance was obtained by reverse osmosis combined with deionization (RO + DI). The type of water treatment that proved most popular was RO alone, which was used by 22 HD centers (61%).(ABSTRACT TRUNCATED AT 400 WORDS)

Bacteria

Use of tunable, pulsed dye laser for quantitative fluorescence in syphilis serology (FTA-ABS test).

A pulsed dye laser was used as an excitation source in a fluorescent treponemal antibody absorption (FTA-ABS) test. A high precision in quantitative fluorescence was obtained with this high-power excitation source coupled to an electronic detection system and a storage oscilloscope by standardization of fluorescence evaluation and through elimination of human error. One 0.4-mus pulse exposure was sufficient to record fluorescence intensity data on the oscilloscope. Absence of fading of fluorescence after repeated excitation permitted multiple readings of the same microscope field. Almost 100% reproducible results were obtained for the FTA-ABS test with 40 samples. Electronic detection of fluorescence and the high sensitivity obtained with laser excitation raise doubts about the relative value of quantitative immunofluorescence in the FTA-ABS test.

Antibodies, Bacterial

[Compared survival of "Escherichia coli" and "Salmonella typhi-murium" in cold water (author's transl)].

The survival rates of Escherichia coli and Salmonella typhi-murium in water are studied at 4, 10 and 20 degrees C and pH 6 and 8, either separately or in mixed culture at four different ratios. S. typhi-murium's survival rate is enhanced at pH 6 and low water temperature. The value of traditional microbiological indicators in assessed in cold water conditions.

Cold Temperature

[Attempted characterization of microorganisms by their metallic profiles].

Ten medically or environmentally significant strains of bacteria were assessed as to their metallic content (Be, Mg, Cr, Mn, Fe, Co, Cu, Zn, Cd and Pb). Metallic detection was performed using a carbon rod-equipped atomic absorption spectrophotometer. Experimental parameters such as heavy metal content of initial culture medium, incubation, "red fuming" nitric acid digestion times, evaporative losses (and their individual correction) plus primary sample dilutions, were standardized. For the ten strains studied, characteristic metallic profiles were observed. More work is needed to assess the taxonomic and epidemiologic significance of metallic profiles of microorganisms.

Bacteria

[Survival of "Pseudomonas aeruginosa" and "Escherichia coli" in cold water (author's transl)].

The survival rates of Escherichia coli and Pseudomonas aeruginosa in water were studied and compared at 4, 10 and 20 degrees C and pH 6 and 8, either separately or in mixed culture at four different concentration ratios. Under ceratin experimental conditions, the temperature, the pH and the bacterial concentration exerted a marked influence on the survival rate. At 4 degrees C, P. aeruginosa may be substituted to E. coli as an effective micriobiological pollution indicator.

Cold Temperature