PubMed HealthSearch

Biomedical subjects

R A Lord

Publications and source records attributed to R A Lord.

3 recordsLinked to original sources

Effect of aprotinin on neutrophil function after major vascular surgery.

High-dose aprotinin reduces blood loss and blood transfusion requirements during liver transplantation and cardiac and vascular surgery. The mechanism of the haemostatic effect of aprotinin is unclear. A general effect on the anti-inflammatory response may be involved. Because leucocyte activation is part of this process, white cell function was measured in patients undergoing aortic surgery who received high-dose aprotinin therapy (n = 10) and was compared with the results from controls who did not (n = 10). The test group received an intravenous bolus (2 x 10(6) kallikrein inhibitor units) of aprotinin after induction of anaesthesia followed by continuous infusion (0.5 x 10(6) kallikrein inhibitor units/h) until the end of the operation. Blood samples were obtained before operation, immediately after surgery, and 1 and 7 days after operation. Aprotinin maintained significantly better postoperative white cell function as measured by bipolar shape formation (P less than 0.001), unstimulated nitroblue tetrazolium (NBT) reduction (P less than 0.001) and chemotaxis (P less than 0.001). Endotoxin-stimulated NBT reduction was similar in both groups, indicating that neutrophils from treated individuals retained the capacity to respond to oxidative stimuli. Aortic surgery activates neutrophils in vivo, as reflected by impaired chemotaxis and increased superoxide production. Aprotinin protects the cells against this potentially deleterious effect without affecting their ability to respond when provoked. Whether this affects leucocyte interaction with coagulation pathways and contributes to the reduction in blood loss remains to be determined.

Aged

Platelet counting using plasma platelet concentrate samples.

Platelet counting using samples of plasma from platelet concentrates prepared for transfusion was assessed. The methods employed included a manual phase-contrast method, and counting with Coulter S Plus and Sysmex E-2500 counters. All methods were reproducible (mean CV of 4.9, 2.2 and 1.4%, respectively). However, neat samples of platelet concentrates analysed by Coulter counter were inaccurate (mean count of 863.8 x 10(9)/l compared to 1018.9 x 10(9)/l counted manually). Moreover, the Coulter platelet counts were non-linear above 900 x 10(9)/l, whereas the E-2500 platelet counts were linear to 2700 x 10(9)/l. A one-in-three pre-dilution was required to obtain accurate, linear counts with the Coulter counter, whereas the E-2500 was accurate without pre-dilution (mean count of 1030.2 x 10(9)/l compared to 1018.9 x 10(9)/l counted manually). In conclusion, the method of platelet counting may affect true platelet yields.

Automation

Effect of specific antibodies on chronic echovirus type 5 encephalitis in a patient with hypogammaglobulinemia.

The effects of specific antibodies in chronic echovirus type 5 (echo 5) encephalitis were investigated in a patient with x-linked hypogammaglobulinemia. Virus was detected in cerebrospinal fluid (CSF) and blood despite treatment with commercial human gammaglobulin that contained low titers of antibodies to echo 5 (0.6 x 10(4) units per injection). Virus disappeared from blood and CSF when plasma containing high concentrations of antibodies (total dose, 1--4 x 10(4) units/kg) was administered intravenously. Maximal inhibition of virus was achieved in culture and in the patient's CSF when the titer of antibody to echo 5 in CSF was greater than or equal to 16 units/ml. Although the patient died, hyperimmune plasma improved the neurologic status and eliminated detectable virus from the blood and CSF.

Agammaglobulinemia