Role of peritoneal cavity lymphatic absorption in peritoneal dialysis.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to R A Mactier.
Explore the source record for details and available documents.
We have reported a case of Guillain-Barré syndrome developing in a patient with kappa light chain myeloma and acute renal failure. No improvement in acute polyneuritis was observed with serial plasma exchange. At autopsy, peripheral nerves showed no evidence of perivascular lymphocytic infiltration or demyelination, no amyloidosis, and no myelomatous infiltration.
The contribution of peritoneal cavity lymphatic absorption to ultrafiltration kinetics and solute clearances in continuous ambulatory peritoneal dialysis was evaluated in patients with normal (group 1) and high (group 2) peritoneal permeability X area during 4-h exchanges using 2 liters 2.5% dextrose dialysis solution with 30 g added albumin. Cumulative lymphatic drainage in all continuous ambulatory peritoneal dialysis (CAPD) patients averaged 358 +/- 47 ml per 4-h exchange and reduced cumulative net transcapillary ultrafiltration at the end of the exchange by 58 +/- 7.2%. The peak ultrafiltration volume was observed before osmotic equilibrium between serum and dialysate was reached and occurred when the net transcapillary ultrafiltration rate had decreased to equal the lymphatic absorption rate. Thereafter the lymphatic absorption rate exceeded the net transcapillary ultrafiltration rate, and intraperitoneal volume decreased. Extrapolated to 4 X 2 liters, 2.5% dextrose, 6-h exchanges per d, lymphatic drainage reduced potential daily net ultrafiltration by 83.2 +/- 10.2%, daily urea clearance by 16.9 +/- 1.9%, and daily creatinine clearance by 16.5 +/- 1.9%. Although lymphatic absorption did not differ between the two groups, lymphatic drainage caused a proportionately greater reduction in net ultrafiltration in group 2 (P less than 0.025), because these patients had more rapid dialysate glucose absorption (P less than 0.05) and less cumulative transcapillary ultrafiltration (P less than 0.01). These findings indicate that cumulative lymphatic drainage significantly reduces net ultrafiltration and solute clearances in CAPD and that ultrafiltration failure in CAPD occurs when daily lymphatic absorption equals or exceeds daily transcapillary ultrafiltration. Reduction of lymphatic absorption may provide a means for future improvement in the efficiency of CAPD.
The efficacy of calcium carbonate (CaCO3) as a phosphate binder has been limited by its tendency to cause hypercalcemia. Since standard dialysate calcium concentrations (3.0-3.5 mEq/l) increase the risk of developing hypercalcemia with large doses of CaCO3 by inducing positive calcium balance during hemodialysis (HD), we compared control of hyperphosphatemia in 41 HD patients during 4 months each of aluminum hydroxide (Al(OH)3) and CaCO3 when the dialysate calcium concentration was lowered, as required, to maintain the predialysis serum calcium concentration within the normal range. Mean predialysis serum phosphorus and calcium concentrations were 5.0 +/- 0.2 mg/dl and 9.3 +/- 0.1 mg/dl, respectively, during 4 months CaCO3 (9.2 +/- 0.3 g/day) and 4.9 +/- 0.2 g/dl and 9.1 +/- 0.1 mg/dl during the previous 4 months Al(OH)3 therapy (2.9 +/- 0.2 g/day). Reducing the dialysate calcium concentration to below 3.0 mEq/l (mean 2.1 +/- 0.04) in the 11 patients who developed hypercalcemia on CaCO3 decreased serum calcium (-1.1 +/- 0.15 mg/dl) and ionized calcium (-0.3 +/- 0.04 mEq/l) during HD, enabled CaCO3 (8.8 +/- 0.4 g/day) to be continued, and maintained predialysis serum calcium and phosphorus at 10.4 +/- 0.1 mg/dl and 5.2 +/- 0.3 mg/dl, respectively. No improvement in acidosis or biochemical hyperparathyroidism was observed during CaCO3 therapy but serum aluminum was significantly decreased after CaCO3 (p less than 0.005). We conclude that CaCO3 prevents interdialytic hyperphosphatemia as effectively as Al(OH)3 without increasing the predialysis serum calcium x phosphorus product, provided serum calcium is maintained within the normal range by adjusting the dialysate calcium concentration.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A diverse range of infectious diseases has presented with acute renal failure (ARF) in the West of Scotland in the past five years. Full recovery is possible provided the specific diagnosis is made early and treatment with temporary renal support is combined with effective antimicrobial therapy.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
OBJECTIVE: To describe the results of Tenckhoff catheter salvage by a modified, closed, stiff-wire manipulation technique without the use of general anesthesia or fluoroscopy, and compare this with previously described techniques. DESIGN: Retrospective study in patients treated with continuous ambulatory peritoneal dialysis (CAPD) over a 41-month period. SETTING: Renal unit in an inner city hospital. PATIENTS: Eighteen patients using CAPD who had 22 episodes of outflow failure due to radiologically confirmed malposition of straight two-cuff Tenckhoff catheters. INTERVENTIONS: Closed stiff-wire manipulation of malpositioned Tenckhoff catheter without the use of general anesthesia or fluoroscopy. MAIN OUTCOME MEASURES: Initial success rate of manipulation, catheter and technique (CAPD) survival, and procedure-related complications. RESULTS: Catheter manipulation was technically successful in 21 of 22 cases. An additional six episodes of malposition occurred ranging from 2 to 630 days after the primary manipulation (median 7 days). A second manipulation was carried out in four cases that resulted in long-term success in two. Three patients were forced to discontinue CAPD for reasons other than catheter malposition, and the overall success rate at 1 month (patient successfully performing CAPD) was 59.1% (+/-0.1%). No major complications were experienced during the procedure and no episodes of peritonitis occurred. CONCLUSION: The technique described is relatively straightforward, does not require fluoroscopy or general anesthetic, and its success is comparable to previously reported methods of Tenckhoff catheter salvage. We would recommend this technique of catheter salvage in patients with Tenckhoff catheter malposition in whom conservative treatment has failed.