Bone metal mobilization induced by long-term desferrioxamine B therapy in continuous ambulatory peritoneal dialysis.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to R A Romero.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The present study describes the relationship between the whole blood Pb, plasma Al and plasma V levels and the arterial hypertension, for four groups of individuals: 20 normotensive azotemic patients in periodic hemodialysis (CRF), 20 hypertensive azotemic patients in periodic hemodialysis (CRF-AHT), 20 individuals with severe essential hypertension and normal renal function (AHT) and 20 individuals with normal renal function and normal blood pressure (controls) evaluated during a period of 1 year. The renal population's blood Pb was comparable with that found in the non-renal groups. Blood Pb in the essential AHT was higher than in controls (P < 0.05). CRF and CRF-AHT showed higher Al levels than those individuals with normal renal function (P < 0.01). In CRF, plasma Al did not correlate with the arterial hypertension. Plasma Al was increased in the AHT individuals (P < 0.05) with respect to the control group, suggesting the possible influence of this metal in the appearance of the arterial hypertension. In this study, the CRF-AHT patients had plasma V statistically higher (P < 0.005) than controls. However, no differences were found between plasma V of CRF and CRF-AHT groups or between AHT and controls. These results suggest that V in AHT is of doubtful significance, except maybe when the renal failure and the arterial hypertension appear together. In summary, high levels of blood Pb and plasma Al are associated with arterial hypertension in individuals without renal disease. Higher plasma V levels were not found in hypertensives with normal renal function with respect to controls.
Fast furnace program (total furnace time < 45 s) electrothermal atomization atomic absorption spectrometric (ETA-AAS) determinations of total Cr in several clinical materials were carried out in conventional (DABC) and transverse (ZEBC) heated graphite atomizers. Before spectrometric determination, test portions of the samples were diluted at different ratios in appropriate solvents: (a) whole blood (WB), blood plasma (BP), blood serum (BS), and red blood cells (RBC), 1 + 4 in 0.1% (v/v) Triton X-100; (b) urine (U), 1 + 4 in 0.1% (v/v) Triton X-100 + 0.01 mol/L nitric acid; and (c) bone (B) specimens and the certified reference materials after microwave mineralization, 1 + 9 in 0.01 mol/L nitric acid. The refractoriness of Cr allowed pyrolysis at a high temperature (approximately 1650 degrees C). As a consequence, two facts arose: first, isoformation was unnecessary; and second, background correction, independent of use of continuum source (DABC design) or Zeeman effect (ZEBC design) correction, was not required. For these reasons, the fast furnace program ETA-AAS analyses were simply done by automatic injection of 10-microL aliquots of the diluted test portions (or aqueous Cr standards) into either pyrolytic graphite-coated graphite tubes (DABC design; wall atomization performed) or pyrolytic graphite-coated graphite tubes with integrated pyrolytic graphite platforms (ZEBC design; integrated platform atomization performed), using neither analyte isoformation nor background correction; wall atomization in coated tubes was preferred. Under these experimental conditions, the limits of detection (3 sigma, micrograms/L Cr) and the characteristic masses (pg of Cr) were 0.03 and 2.7 (DABC design) and 0.2 and 5.0 (ZEBC design), respectively.(ABSTRACT TRUNCATED AT 250 WORDS)
Total dissolved aluminum, calcium, iron, potassium, magnesium and sodium were evaluated in the drinking water supplied to the city of Maracaibo, Venezuela, to ascertain the water quality for human consumption. Mean concentrations (+/- S.D.) of 533 +/- 313 micrograms/l Al, 32 +/- 4 mg/l Ca, 167 +/- 104 micrograms/l Fe, 2 +/- 1 mg/l K, 5 +/- 2 +/- 1 mg/l K, 5 +/- 1 mg/l Mg and 16 +/- 4 mg/l Na were obtained during a 4-month sampling period that included dry (January-February 1991) and wet (March-April 1991) seasons. Significant seasonal variations (P < 0.002) for aluminium, potassium and magnesium were as follows: 641 +/- 275 and 445 +/- 340 micrograms/l aluminium, 3 +/- 0.5 and 2 +/- 0.5 mg/l potassium and 4 +/- 0.2 and 6 +/- 2 mg/l magnesium for the wet and dry seasons, respectively. The concentration of aluminum was consistently higher than the levels accepted by most international water quality criteria (approximate acceptable value < 300 micrograms/l aluminum), probably because of the inadequate flocculation treatment given to the raw water at the water plant. The rest of the metals under consideration complied with international guidelines of quality criteria for drinking water. The presence of an elevated concentration of humic material (22 +/- 2 mg/l of total organic carbon) in the drinking water should be a matter of public concern.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Bone accumulation of metals, other than aluminum (Al), in patients with chronic renal failure (CRF) has rarely been studied. We report the bone and blood levels of iron (Fe), vanadium (V), lead (Pb), Al and calcium (Ca) in 18 CRF patients on long-term hemodialysis and in 14 controls (C). Significant increments in mean blood Al (1,300%), V (160%) and Fe (60%) and decrease in blood Pb (-50%) were found in the patients with CRF. Renal subjects had higher bone concentrations (mean +/- S.E.M.; microgram/g of bone) of Al (CRF = 129.1 +/- 16.9; C = 12.6 +/- 2.9; P < 0.0001), Fe (CRF = 940.4 +/- 133.4; C = 263.4 +/- 49.0; P < 0.0001) and V (CRF = 2.55 +/- 0.43; C = 1.39 +/- 0.36; P = 0.0308) and lower Ca (CRF = 268.2 +/- 11.1 mg/g; C = 377.2 +/- 28.1; P = 0.0017). A positive correlation was found between bone Al and V (r = 0.355, P < 0.05). Results indicated that a significant bone accumulation of Al, Fe and V, but not Pb, occurred in the hemodialyzed azotemic individuals.
Two sampling sessions were carried out in Lake Maracaibo and eight sites selected in four pairs one in front of the other (El Moján-Ancón de iturre, Santa Cruz de Mara-Punta de Palmas, Maracaibo-Punta de Leiva and San Francisco-La Rita). Specimens of Cynosción acoupa Maracaiboencis (curvina, n = 5), Oligoplites palometa (palometa, n = 5), Penaeus schmitti (shrimp, n = 20), and Polymesoda arctata (mussels, n = 20) were collected. For the curvina and palometa, muscle, brain, kidney, gill, liver and heart were analysed. Shrimp and mussels were analysed whole, without the shells. Samples were lyophilized and cold digested in a mixture of sulfuric, nitric and perchloric acids, potassium permanganate and hydrogen peroxide. Spectrometric determination was carried out using cold vapour atomic absorption spectrometry and sodium borohydride as reducing agent. Accuracy was tested with a National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) RM50 Albacore Tuna, and against another method. The detection limit for Hg was 53 ng l-1. Good agreement was found between results for the analysis of SRM RM50 (Hg = 0.95 +/- 0.14 mg kg-1) and the assigned value furnished by NIST (Hg = 0.95 +/- 0.10 mg kg-1). Precision and the interference were also evaluated. Mercury concentrations in brain, kidney and heart tissues of the curvina and palometa were found to be higher than those in the muscle tissue.
Explore the source record for details and available documents.
In the present work we report the bone histologies obtained from the iliac crest of 49 patients on chronic hemodialysis in Maracaibo. All of them were dialyzed thrice weekly with untreated tap water containing high aluminum (Al) levels. Their mean blood Al levels were found to be higher than 100 micrograms/L. Histomorphometry was used for the diagnosis of the underlying renal osteodystrophic type. Al-staining techniques (Aluminum) were applied for detection of bone Al deposits. Additionally, bone Al content was determined quantitatively by means of graphite furnace atomic absorption spectroscopy. A mixed type of osteodystrophy (type III according to Delling's classification) consisting in the simultaneous presence of hyperparathyroid bone lesions (osteitis fibrosa, OF) and a hyperosteoidosis (osteomalacia, OM) was found in 63.3% of the studied patients. The other patients (37.7%) exhibited a pure osteomalacia (OM). Bone Al deposits at the mineralization front were observed in 70% of cases and were frequently associated with bone pain, spontaneous fractures and skeletal deformities. We conclude that bone biopsy should be performed in all patients presenting bone pain and high blood Al levels.
We studied the removal of aluminum (Al), iron (Fe), copper (Cu), lead (Pb) and zinc (Zn) with continuous ambulatory peritoneal dialysis, before and after desferrioxamine B (DFO) administration (2 g intravenously) in two patients with chronic renal failure and Al-related osteopathy. Both patients had 4 peritoneal dialysis exchanges (2 liters each) per day. Blood concentrations of Al increased 413% (patient A) and 190% (patient B) after DFO. Patient B had a 15% increase in Fe; other metals remained unchanged. Dialysate efflux Al concentrations had peak post-DFO increments of 761% and 840% in patients 1 and 2, respectively. Peak post-DFO increments in Fe dialysate concentration were 342% and 89.5% in the respective patients. Dialysate/plasma (D/P) concentration ratios of Al increased from pre-DFO levels (mean +/- SEM) of 0.370 +/- 0.048 to 0.523 +/- 0.061 after DFO; similarly, Fe D/P ratios increased from 0.259 +/- 0.053 to 0.446 +/- 0.075 with DFO therapy. These results indicate an increase in the ultrafiltrable proportion of Al and Fe in plasma after DFO administration. During 3 days after DFO, patient 1 had a total removal of Al and Fe of 2.9 mg and 4.9 mg, respectively. Metal removal in patient 2 was 7.6 mg of Al and 2.7 mg of Fe. Peritoneal extraction of other trace metals was minor.
In this work we present a graphite furnace atomic absorption spectrometric method for blood lead using palladium as a chemical modifier. Whole blood was diluted 10- fold with a 0.1% v/v triton X-100 solution; 10 microL of this solution and 10 microL of the palladium-based modifier (2 mg Pd/L, 2% w/v citric acid and 0.01 M nitric acid) were injected onto the L'vov platform by using the alternate volume mode. The following furnace operating parameters were used: (a) drying steps, 120 degrees C for 10s and 250 degrees C for 30s; (b) pyrolysis steps, 800 degrees C for 45s (with oxygen) and 1100 degrees C for 25s; (c) atomization, 1600 degrees C for 3s; (d) clean out, 2700 degrees C for 4s. Accuracy was tested by using (i) a NIST standard (SRM-909) and the Behring Control Blood for Metal 1 (OSSD 21) with lead concentrations of 23.7 +/- 2.1 micrograms/L (found: 21.2 +/- 0.7 micrograms/L) and 413 +/- 51 micrograms/L (found: 407 +/- 6 micrograms/L), respectively; (ii) recovery studies (ca. 100 +/- 1%), and (iii) a reported method (mean relative error: 5.1%). Approximate standard deviations of 0.3 (within-run) and 0.7 (between-runs) micrograms Pb/L were found in the precision study. The detection limit (3 sigma) and the characteristic mass (for a 10- microL injection volume) were 0.1 micrograms Pb/L and 15 pg/0.0044 A.s, respectively. The proposed method was used to establish the lead levels of patients with renal insufficiency; a mean concentration (+/- SD) of 59 +/- 39 micrograms Pb/L (range: 12- 160 micrograms Pb/L) was found. The method was interference-free, reliable and reproducible.
The placental transfer of lead (Pb) from mother to newborn in seventeen pregnant women receiving medical care at Adolfo Pons Hospital, Maracaibo (Venezuela), is presented. Maternal blood was collected by venipuncture during the first stage of labor, while neonatal blood was taken from the umbilical cord vein; placental blood samples were obtained at the time of delivery. Lead determination was carried out by graphite furnace atomic absorption spectrometry. Blood Pb levels (mean +/- SD, microgram/L) of 53.2 +/- 31.8, 46.3 +/- 24.5 and 66.3 +/- 33.3 were found for newborns, placentas and mothers, respectively. Significant blood Pb correlations were observed. Results indicated that even when the mother had a low blood lead level the placenta did not have a restrictive barrier-type effect to protect against Pb transfer from mother to newborn. Neonates' blood Pb concentrations were much lower than the accepted upper limit of 250 micrograms/L Pb.
The present work reports the concentrations of aluminum in whole blood and dialysis solutions of 27 patients with chronic renal failure and under hemodialysis treatment at Miguel Pérez Carreño and University Hospitals, both from Caracas city. Aluminum levels of the water used to prepare the dialysates were also monitored and the metal mobilization during dialysis studied. Patients' mean blood aluminum concentrations (ca. 34 micrograms AI/L) were lower than those of renal individuals from Maracaibo (ca. 58 micrograms AI/L), situation related to the low metal contents of the dialysate water (ca. 14 micrograms AI/L). In addition, Caracas drinking water showed up very high aluminum concentrations, above 475 micrograms/L. There was a relationship between the renal patients' blood aluminum concentrations and (1) the metal contents of the dialysis solutions and (2) the ingestion of aluminum hydroxide-based antacids. Aluminum transfer incorporation processes toward the patients' blood were observed in both dialysis units. This was due to the favorable concentration gradients (blood aluminum concentration/dialysate aluminum concentration) established at the start of every hemodialysis treatment.
Patients with chronic renal failure (CRF) on periodical hemodialysis may accumulate aluminum in tissues and show typical disorders such as dialysis encephalopathy, osteodystrophy, and microcytic anemia. Aluminum contamination of the water used to prepare the dialysis solution (dialysate) is one of the metal sources that may affect people under hemodialysis, especially in units in which untreated water is used. Graphite furnace atomic absorption spectrometric methods for aluminum determination in whole blood, dialysis solution, and tap water samples from CRF patients were developed, based upon the use of the same furnace temperature program. Samples were diluted 4-fold with 0.6% triton X-100 (whole blood) or with 0.01 mol/L nitric acid (dialysis solution and tap water) and analyzed by aqueous standard (blood and tap water) or matrix-matching standard (dialysis solution) calibration curves. The characteristic masses were 33.8, 11.3, and 19.5 pg Al/0.0044 A.s for whole blood, dialysate, and tap water, respectively. In the diluted solutions, the detection limits (2 sigma) for the described methods were 0.5 microgram/L Al (whole blood), 0.4 microgram/L Al (dialysate), and 0.4 microgram/L Al (tap water). The methods were applied to samples from several CRF patients under hemodialysis at Maracaibo University hospital. The data revealed extremely high aluminum levels, which corresponded to the symptoms of dialysis encephalopathy and/or osteodystrophy showed by some of them. The proposed methods are reliable and reproducible.