[An electrochemical method of determining peroxidase in saliva].
Electrochemical method has been developed for measuring human salivary peroxidase. Salivary peroxidase levels were measured in donors in various hours of the day, in girls in various periods of the cycle, and in myocardial infarction patients. The results may be used to develop rapid methods for assessment of ovarian functional activity and for prediction of myocardial infarction outcome. Electrochemical analysis productivity is 360 samples per hour, the minimal peroxidase concentration detectable is 5.10(-12) M.