PubMed Health⌕ Search

Biomedical subjects

R Albiero

Publications and source records attributed to R Albiero.

At least 19 recordsLinked to original sources

Angiographical follow-up after radioactive "Cold Ends" stent implantation: a multicenter trial.

BACKGROUND: Radioactive stents with an activity of 0.75 to 12 microCi have shown >40% edge restenosis due to neointimal hyperplasia and negative remodeling. This trial evaluated whether radioactive Cold Ends stents might resolve edge restenosis by preventing remodeling at the injured extremities. METHODS AND RESULTS: The 25-mm long (15-mm radioactive center and 5-mm nonradioactive ends) Cold Ends stents had an activity of 3 to 12 microCi at implantation. Forty-three stents were implanted in 43 patients with de novo native coronary artery disease. Two procedural, 1 subacute, and 1 late stent thrombosis occurred. A restenosis rate of 22% was observed with a shift of the restenosis, usually occurring at the stent edges of radioactive stents, into the Cold Ends stents. The most severe restenosis occurred at the transition zone from radioactive to nonradioactive segments, a region located in dose fall-off. CONCLUSION: Cold Ends stents did not resolve edge restenosis.

Adult↗

Discrepancy between angiography and intravascular ultrasound when analysing small coronary arteries.

AIMS: A small reference diameter may be the consequence of high plaque burden and diffuse disease. The reference vessel diameter in small coronary arteries may vary according to the method of measurement used. We endeavoured to confirm the difference between data from examinations conducted using angiography with that revealed by intravascular ultrasound. METHODS AND RESULTS: Between March 1993 and October 1999, 344 consecutive patients with 419 lesions in small vessels (< or =2.75 mm, Small group) and 953 patients with 1161 lesions in large vessels (Large group) underwent intravascular ultrasound-guided percutaneous transluminal angioplasty in our Institution. The mean difference between the intravascular ultrasound and the angiographic reference diameter (Delta(IVUS-Angio)) was 1.3+/-0.5 mm in the Small group and 1.0+/-0.6 mm in the Large group (P<0.001). There was a stronger correlation between plaque burden and Delta(IVUS-Angio)in the Small group (r=0.80, P<0.001) than in the Large group (r=0.59, P<0.001). An Delta(IVUS-Angio)> or =0.30 mm occurred in 99.5% of cases in the Small group and in 90% in the Large group (P<0.001). An Delta(IVUS-Angio)> or =0.50 mm occurred in 96% of case in the Small group and 80% in the Large group (P<0.001). Predictors of Delta(IVUS-Angio)> or =0.50 in the Small group were: proximal or middle lesion site, vessel type (left anterior descending artery, diagonal and obtuse marginal branches) and female sex. An Delta(IVUS-Angio)> or =1.0 mm occurred in 71% of cases in the Small group and in 49% in the Large group (P<0.001). Predictors of Delta(IVUS-Angio)> or =1.0 mm in the Small group were: proximal or middle lesion site, female sex, and lesion length. CONCLUSIONS: A high percentage of vessels measuring < or =2.75 mm are large vessels with a high plaque burden. This condition is particularly prevalent in females, with lesions in the proximal or middle left anterior descending artery, and in obtuse marginal and diagonal branches.

Aged↗

Intravascular ultrasound-guided percutaneous transluminal coronary angioplasty with provisional spot stenting for treatment of long coronary lesions.

OBJECTIVES: The purpose of this study was to evaluate the approach of intravascular ultrasound (IVUS)-guided percutaneous transluminal coronary angioplasty (PTCA) with spot stenting (SS) for the treatment of long coronary lesions. BACKGROUND: Treating long coronary lesions with balloon angioplasty results in suboptimal short- and long-term outcomes. Full lesion coverage with traditional stenting (TS) has been associated with a high restenosis rate. METHODS: We prospectively evaluated a consecutive series of 130 long lesions (>15 mm) in 101 patients treated with IVUS-guided PTCA and SS. The results were compared with those of TS in a matched group of patients. Coronary angioplasty was performed with a balloon to vessel ratio of 1:1, according to the IVUS media-to-media diameter of the vessel at the lesion site, to achieve prespecified IVUS criteria: lumen cross-sectional area (CSA) > or =5.5 mm(2) or > or =50% of the vessel CSA at the lesion site. The stents were implanted only in the vessel segment where the criteria were not met. RESULTS: In the SS group, stents were implanted in 67 of 130 lesions, and the mean stent length was shorter than that of lesions in the matched TS group (10.4 +/- 13 mm vs. 32.4 +/- 13 mm, p < 0.005). The 30-day major adverse cardiac event (MACE) rate was similar (5%) for both groups. Angiographic restenosis was 25% with IVUS-guided SS, as compared with 39% in the TS group (p < 0.05). Follow-up MACE and target lesion revascularization rates were lower in the SS group than in the TS group (22% vs. 38% [p < 0.05] and 19% vs. 34% [p < 0.05], respectively). CONCLUSIONS: Intravascular ultrasound-guided SS for the treatment of long coronary lesions is associated with good acute outcome. Angiographic restenosis and follow-up MACE rates were significantly lower than those with TS.

Aged↗

Cerebral protection with filter devices during carotid artery stenting.

BACKGROUND: Distal embolization of debris during percutaneous carotid artery stenting may result in neurological deficit. Filter devices for cerebral protection potentially reduce the risk of embolization. METHODS AND RESULTS: Elective carotid stent implantation using 3 different types of distal filter protection devices was attempted in 88 consecutive lesions (84 patients) in the internal carotid artery that had >70% diameter stenosis (mean, 78.7+/-10.7%). Procedures were performed in 3 different centers. The mean age of the patients was 69+/-8 years, 75% were men, and 35.7% had neurological symptoms. In 86 lesions, a stent was successfully implanted (97.7%). In 83 of these 86 procedures (96.5%), it was possible to position a filter device. In 53% of filters, there was macroscopic evidence of debris. Collected material consisted of lipid-rich macrophages, fibrin material, and cholesterol clefts. Neurological complications during the procedure, in the hospital, and at 30 days of clinical follow-up occurred in only one patient (1.2%). This patient suffered a minor stroke that resolved within 1 week. Two major adverse cardiac events (2.3%) occurred during the 30 days of follow-up. CONCLUSIONS: Filter protection during carotid artery stenting seems feasible and safe. In the present series, the incidence of neurological complications was low.

Aged↗

Predictors of diffuse and aggressive intra-stent restenosis.

OBJECTIVES: This study was performed to investigate the causes of diffuse and aggressive intra-stent restenosis. BACKGROUND: Although restenosis is usually considered to be a dichotomous variable, there is clinical relevance to the severity of restenosis. It is not known which variables are predictive of diffuse or aggressive intra-stent restenosis. METHODS: A consecutive series of 456 coronary lesions with in-stent restenosis was evaluated for the type of restenosis using quantitative coronary angiography. Restenosis was defined as > or = 50% diameter stenosis at follow-up angiography, diffuse restenosis as a follow-up lesion length > or = 10 mm and aggressive restenosis as either an increase in lesion length from the original lesion or a restenotic narrowing tighter than the original. Clinical, anatomic and procedural characteristics were evaluated for lesions associated with these types of restenosis. RESULTS: Diffuse restenosis was associated with a smaller reference artery diameter, longer lesion length, female gender, longer stent length and the use of coil stents. Aggressive restenosis was more common in women, with the use of Wallstents and with long stent to lesion length ratios. Aggressive restenosis occurred earlier and was more closely associated with symptoms and myocardial infarctions than nonaggressive restenotic lesions. CONCLUSIONS: Markers for diffuse restenosis were also important markers for the presence of any restenosis. A long stent to lesion length ratio is an important marker for aggressive restenosis. When severe forms of in-stent restenosis occur, they tend to present earlier and with more symptoms, including myocardial infarction. More careful consideration of the type of in-stent restenosis may aid in identifying when alternative strategies may be useful.

Coronary Angiography↗

Directional atherectomy prior to stenting in bifurcation lesions: a matched comparison study with stenting alone.

The ideal catheter-based intervention for treatment of coronary lesions at bifurcation site still has to be defined. The aim of the study was to assess the acute and long-term outcome after treatment of bifurcation lesions with directional atherectomy (DCA) and stenting in comparison with stenting alone. Thirty-one consecutive patients treated for bifurcation coronary lesions (62 lesions) with DCA and stenting in at least one branch (DCA group) were compared with a matched group of 31 patients with bifurcation coronary lesions (62 lesions) treated with stenting alone in at least one branch (non-DCA group). Procedural success was 87.1% in the DCA group compared with 100% in the non-DCA group (P = 0.03). In-hospital major adverse cardiac events (MACE) occurred only in the DCA group (12.9% vs. 0%, P = 0.03), mainly non-Q-wave myocardial infarction. After the procedure, minimum lumen diameter (MLD) and acute gain were significantly greater (P = 0.004 and P = 0.05, respectively) and % diameter stenosis was significantly lower (P = 0.05) in the main branch in the DCA group. At follow-up angiogram, MLD in the main branch was still significantly greater in the DCA group compared to the non-DCA group (2.31 vs. 1.65, respectively, P = 0.04), with no significant difference in late loss and loss index between the two groups. Restenosis rate was 28.8% in the DCA group vs. 43.5% in the non-DCA group (P = 0.13). The incidence of follow-up MACE was 29% in the DCA group compared with 48.4% in the non-DCA group, mainly due to target lesion revascularization. In conclusion, treatment of bifurcation coronary lesions with DCA and stenting was associated with greater acute gain after the procedure and greater MLD at follow-up in the main branch compared with stenting alone. Procedural myocardial infarction was more frequent in the DCA group. Restenosis rates and follow-up MACE were lower following DCA and stenting, without reaching any statistical significance.

Adult↗

Cutting balloon angioplasty for treatment of calcified coronary lesions.

The aim of the study was to evaluate the feasibility, safety, and efficacy of cutting balloon angioplasty in treatment of angiographically moderate and severe calcified coronary lesions. Thirty-seven calcified coronary lesions (29 patients) detected by angiography were dilated with cutting balloon. Predilatation with plain balloon was performed in 27 (73.0%) lesions and stent was implanted in 23 (62.2%) lesions following cutting balloon. Acute gain following cutting balloon in predilated lesions was compared to the acute gain following plain balloon predilatation. For predilated lesions, acute gain after cutting balloon was significantly greater compared with plain balloon predilatation (1.51 +/- 0.49 vs. 0.77 +/- 0.42; P = 0.01). This result was achieved with larger size and lower pressure of cutting balloon compared with plain balloon (3.28 +/- 0.46 vs. 2.94 +/- 0.55, P = 0.01; 10.38 +/- 1.64 vs. 13.19 +/- 3.63, P = 0.001, respectively). The final gain following cutting balloon dilatation was significantly higher than the expected gain obtained by using a plain balloon of the same size (1.51 +/- 0.49 vs. 0.93 +/- 0.48; P < 0.0001), which was inflated at significantly higher pressure compared with cutting balloon. When we compared acute gain following cutting balloon in lesions with and without predilatation, we found no significant difference (P = 0.31). Angiographic success was achieved in 36 (97.3%) lesions and procedural success in 33 (89.1%) lesions. In-hospital major adverse cardiac event (MACE) occurred in three (10.3%) patients. Follow-up MACE was reported from three (10.3%) patients. In conclusion, cutting balloon angioplasty is feasible and safe in treatment of angiographically moderate and severe calcified lesions. Dilating efficiency of cutting balloon seems to be greater compared with a plain balloon of the same size, which was inflated at significantly higher pressure compared with cutting balloon. These results can be achieved with low in-hospital MACE and are associated with a good long-term outcome.

Aged↗

Cutting balloon angioplasty for the treatment of in-stent restenosis: a matched comparison with rotational atherectomy, additional stent implantation and balloon angioplasty.

OBJECTIVES: The purpose of the study was to determine whether cutting balloon angioplasty (CBA) has advantages over other modalities in treatment of in-stent restenosis (ISR). BACKGROUND: Controversies exist regarding optimal treatment for ISR. Recently, CBA emerged as a tool in management of ISR. METHODS: A total of 648 lesions treated for ISR were divided into four groups according to the treatment strategy: CBA, rotational atherectomy (ROTA), additional stenting (STENT), and percutaneous transluminal coronary angioplasty (PTCA). Following the matching process, 258 lesions were entered into the analysis. RESULTS: Baseline clinical and angiographic characteristics were similar among the groups (p = NS). Acute lumen gain was significantly higher in the STENT group (2.12 +/- 0.7 mm), whereas in the CBA group the gain was similar to one achieved following ROTA and following PTCA (1.70 +/- 0.6 vs. 1.79 +/- 0.5 mm and 1.56 +/- 0.7 mm, respectively; p = NS). The lumen loss at follow-up was lower for the CBA versus ROTA and versus STENT (0.63 +/- 0.6 vs. 1.30 +/- 0.8 mm and 1.36 +/- 0.8 mm, respectively; p < 0.0001), yielding a lower recurrent restenosis rate (20% vs. 35.9% and 41.4%, respectively; p < 0.05). By multivariate analysis, CBA (odds ratio [OR] = 0.17; confidence interval [CI], 0.06 to 0.51; p = 0.001) and diffuse restenosis type at baseline (OR = 2.07; CI, 1.15 to 3.71; p = 0.02) were identified as predictors of target lesion revascularization. CONCLUSIONS: We conclude that CBA is a safe and efficient technique for treatment of ISR, with immediate results similar to atheroablation and better clinical and angiographic outcomes at follow-up. This approach might be implemented as a viable option in management of focal ISR and to prepare diffuse ISR for brachytherapy treatment.

Aged↗

Characterization of total occlusions with intracoronary ultrasound: the importance of the duration of occlusion.

OBJECTIVE: To assess the impact of the occlusion duration on the characteristics of coronary occlusive plaques. BACKGROUND: The percutaneous recanalization of chronic total coronary occlusions is a technically demanding and yet often unsuccessful procedure due to unfavorable morphological changes described by histology but not well defined in vivo. METHODS: Thirty-five consecutive total occlusions of > or = 1 month duration in previously untreated native coronary arteries were studied using intracoronary ultrasound following dilatation with a 1.5 mm balloon. Plaque characteristics of lesions with an occlusive duration of > or = 3 months (old occlusions) and those of < 3 months (recent occlusions) were then compared. The ultrasound cross-section where there was maximal plaque accumulation at the site of occlusion was analyzed for its qualitative and quantitative characteristics. The lesion remodeling index was defined as the vessel area at occlusion divided by the vessel area at a proximal reference. RESULTS: The old occlusion group comprised 11 lesions whereas 16 lesions were found in the recent occlusion group; the occlusion duration was undetermined in the remaining 8 lesions, and the mean occlusion duration was found to be 4.9 +/- 4.3 months, over a range of 1 36 months. The baseline clinical and angiographic characteristics were similar in the 2 groups. The lesion remodeling index was found to be significantly lower in older occlusions than in the more recent occlusions (0.75 +/- 0.14 vs. 1. 06 +/- 0.25; p = 0.007) and the duration of the occlusion also correlated with the length of calcified segment as determined by ultrasound (p = 0.040), and with a smaller angiographic proximal reference diameter (p = 0.043). CONCLUSION: Long-standing occlusions undergo lesion shrinkage and exhibit more extensive calcification.

Adult↗

Predictors of re-occlusion after successful recanalization of chronic total occlusion.

UNLABELLED: The objective of this study was to highlight the incidence and predictors of re-occlusion after successful recanalization of chronic total coronary occlusions. METHODS AND RESULTS: Following successful recanalization and stent implantation in 716 coronary lesions (665 patients) with chronic total occlusion, four hundred and five (56.6%) lesions (375 patients) underwent repeat angiography within 6 months. Restenosis (> or = 50% lumen narrowing) was observed in 151 (37.3%) lesions; forty-three (10.6%) of these lesions had complete re-occlusion and constituted the study population. In this group, final angiographic minimal lumen diameter (MLD) was 2.6 +/- 0.51 mm and final percent diameter stenosis was 18 +/- 11. Univariate analysis revealed significant correlation between re-occlusion and restenotic lesions, final balloon diameter, final percent diameter stenosis, final angiographic MLD, number of stents per lesion and total stent length. By multivariate analysis, the only independent predictor of re-occlusion was total stent length (OR = 1.46, 95% CI = 1.12-1.82; p = 0.0069). CONCLUSION: Re-occlusion occurs in about 11% of cases after stenting chronic total occlusion. The most important predictor of re-occlusion seems to be stent length.

Aged↗

Polytetrafluoroethylene-covered stent for the treatment of narrowings in aorticocoronary saphenous vein grafts.

We compared the outcome of patients with saphenous graft disease treated with polytetrafluoroethylene (PTFE)-covered stents or noncovered stents. Angiographic success was similar; non-Q-wave myocardial infarction was lower in the PTFE group (p = 0.06) and long-term major cardiac events and restenosis rate were similar in the 2 groups. Implantation of PTFE-covered stent in vein graft disease seems to reduce the occurrence of distal embolization.

Aged↗

Edge restenosis after implantation of high activity (32)P radioactive beta-emitting stents.

BACKGROUND: A high restenosis rate has been reported at the edges ("edge restenosis") of (32)P radioactive stents with an initial activity level of 3 to 12 microCi. This edge effect might be due to balloon injury and to a low dose of radiation at the stent margins. The aim of this study was to evaluate whether the implantation of (32)P radioactive stents with a higher activity level (12 to 21 microCi) combined with a nonaggressive stent implantation strategy could solve the problem of edge restenosis. METHODS AND RESULTS: We compared the results of lesions treated with single radioactive BX stents with an activity of 12 to 21 microCi (group 2, n = 54 lesions) with the results of lesions treated by single radioactive BX stents with an initial activity level of 3 to 12 microCi (group 1, n = 42 lesions). There were no procedural events. At the 6-month follow-up, no myocardial infarctions, deaths, or stent thromboses had occurred. Intrastent binary restenosis was 0% in group 1 versus 4% in group 2 (n = 2, both at the ostium of the right coronary artery, P = NS). Intrastent neointimal hyperplasia was significantly lower in group 2 than in group 1. The intralesion (intrastent plus peri-stent) restenosis rate was 38% in group 1 versus 30% in group 2 (P = NS). Conclusions-Single (32)P radioactive stents with an initial activity level of 12 to 21 microCi reduced intrastent neointimal hyperplasia compared with stents of 3 to 12 microCi, but they did not solve the problem of edge restenosis, even if a nonaggressive stent implantation strategy was used.

Angioplasty, Balloon, Coronary↗

Immediate and long-term results of "T" stenting for bifurcation coronary lesions.

The technique of "T" stenting, which incorporates wiring both the branches of a bifurcation lesion, dilating a balloon in the main branch during stent deployment in the side branch followed by deployment of stent in the main branch, provides excellent immediate results in terms of technical and procedural success. However, further innovations are mandated to optimize the long-term outcome, which with a restenosis rate of 63%, can be described as not encouraging.

Angioplasty, Balloon, Coronary↗

Coronary stenting versus balloon angioplasty in small coronary artery with complex lesions.

The impact of stenting on small vessels (< 3.0 mm) with complex lesions (B2-C) is still controversial. Restenosis rate in this population is high (> 40%). We compared early and late outcome of patients with complex coronary lesions in small vessel treated with traditional coronary angioplasty (angioplasty group) and with elective stent implantation (stent group). Angioplasty group (n = 97) and stent group (n = 112) were comparable for all clinical and angiographic characteristics. All patients in the two groups had clinical and angiographic follow-up. Major adverse cardiac events (MACE) and restenosis rate were evaluated. No patients in the two groups experienced in-hospital death or bypass surgery. Myocardial infarction occurred in four patients in the angioplasty group and in seven patients in the stent group (P = 0.36). No patients in either the angioplasty or the stent group had acute stent thrombosis, whereas subacute stent thrombosis occurred in only one patients of the stent group (0.9%). Long-term MACEs (20 +/- 4 month) were not different in the two groups (angioplasty group 39% vs. stent group 44%, P = 0.35). Target lesion revascularization rate was 33% in the angioplasty group and 34% in the stent group (P = 0.50). Restenosis rate was not statistically different in the two groups (stent group 41% vs. angioplasty group 38%, P = 0.41). In conclusion, compared to balloon angioplasty, elective stent implantation in small vessels with complex lesions does not improve early and late outcome. Cathet. Cardiovasc. Intervent. 50:390-397, 2000.

Angioplasty, Balloon, Coronary↗

Cutting balloon angioplasty for the treatment of in-stent restenosis.

The results using the Cutting Balloon for the treatment of in-stent restenosis may be superior to those of conventional percutaneous transluminal coronary angioplasty (PTCA) or even the combination of PTCA preceded by rotational atherectomy. The reasons for these possible differences are not yet well defined. The case we report suggests that the Cutting Balloon achieves a better final result than conventional PTCA, by making the tissue more amenable to being pushed outward through the stent struts.

Angioplasty, Balloon, Coronary↗

Left internal mammary artery graft perforation repair using polytetrafluoroethylene-covered stents.

The increase in the use of the left internal mammary artery (LIMA) as graft of choice to the left anterior descending coronary artery for conventional and minimally invasive coronary artery bypass surgery has led to an increased incidence of LIMA pathologic lesions early after surgery. The lesion, commonly located in the body of the LIMA graft, is usually caused by mechanical injury during harvesting of the vessel. In this context, percutaneous intervention with stent implantation can be complicated by vessel rupture, which usually requires emergency surgical repair. We describe two cases of stent implantation in newly placed LIMA grafts complicated by vessel rupture, which were successfully repaired using polytetrafluoroethylene-covered stents.

Aged↗

Bifurcation lesions: two stents versus one stent--immediate and follow-up results.

OBJECTIVES: The purpose of this study was to evaluate two different techniques of stent placement in bifurcation lesions. BACKGROUND: Although stent placement with dedicated techniques has been suggested to be a useful therapeutic modality for bifurcation lesions, limited information is available if stent placement on the side branch and on the parent branch provides any advantage over a simpler strategy of stenting the parent vessel and balloon angioplasty of the side branch. METHODS: Between March 1993 and April 1999, we treated a total of 92 patients with bifurcation lesions with two strategies: stenting both vessels (group B, n = 53) or stenting the parent vessel and balloon angioplasty of the side branch (group P, n = 39). Paired angiograms were analyzed by quantitative angiography, and clinical follow-up was obtained. RESULTS: Stent placement on both branches resulted in a lower residual stenosis (7.4 +/- 10.9% vs. 23.4% +/- 18.7%, p < 0.001) in the side branch. Acute procedural success was similar in the two groups (group B: 87% vs. Group P: 92%). In-hospital major adverse cardiac events (MACE) occurred only in group B (13% vs. 0%, p < 0.05). At the six-month follow-up, the angiographic restenosis rate (group B: 62% vs. Group P: 48%) and the target lesion revascularization rate (38% vs. 36%, respectively) were similar in the two groups. There was no difference in the incidence of six-month total MACE (51% vs. 38%). CONCLUSIONS: For the treatment of true bifurcation lesions, a complex strategy of stenting both vessels provided no advantage in terms of procedural success and late outcome versus a simpler strategy of stenting only the parent vessel.

Aged↗