PubMed Health⌕ Search

Biomedical subjects

R Altemus

Publications and source records attributed to R Altemus.

16 recordsLinked to original sources

Optically stimulated luminescent glass optical fibre dosemeter.

An optical fibre radiation dosemeter has been developed that utilises optically stimulated luminescence and scintillation to provide independent, remote, real-time dose measurements. The radiation sensitive element consists of a 1 mm long, 0.4 mm diameter piece of copper-ion-doped fused quartz that is attached to a 1 m length of commercial optical fibre. The dosemeter probe is 0.6 mm in diameter and is flexible enough to be used in standard medical catheters for internal radiation dose measurements. A four-channel dosemeter system has been built and characterised under conditions typical of a radiotherapy environment. The device exhibits a linear response over the range of doses from 0.01 Gy to 10 Gy. The dosemeter responds identically to both electrons and photons in the range from 4 to 20 MV and the calibration was retained to within +/-2% over a period of 4 weeks. The fibre dosemeter has been used successfully to verity doses received by three patients receiving radiotherapy treatments.

Calibration↗

Inhibitor of histone deacetylation, depsipeptide (FR901228), in the treatment of peripheral and cutaneous T-cell lymphoma: a case report.

Depsipeptide, FR901228, has demonstrated potent in vitro and in vivo cytotoxic activity against murine and human tumor cell lines. In the laboratory, it has been shown to be a histone deacetylase (HDAC) inhibitor. In a phase I trial of depsipeptide conducted at the National Cancer Institute, 3 patients with cutaneous T-cell lymphoma had a partial response, and 1 patient with peripheral T-cell lymphoma, unspecified, had a complete response. Sézary cells isolated from patients after treatment had increased histone acetylation. These results suggest that inhibition of HDAC is a novel and potentially effective therapy for patients with T-cell lymphoma.

Acetylation↗

Transplant dose of CD34(+) and CD3(+) cells predicts outcome in patients with haematological malignancies undergoing T cell-depleted peripheral blood stem cell transplants with delayed donor lymphocyte add-back.

We sought to optimize and standardize stem cell and lymphocyte doses of T cell-depleted peripheral blood stem cell transplants (T-PBSCT), using delayed add-back of donor T cells (DLI) to prevent relapse and enhance donor immune recovery. Fifty-one patients with haematological malignancies received a T-PBSCT from an HLA-identical sibling, followed by DLI of 1 x 10(7) and 5 x 10(7) CD3(+) cells/kg on d +45 and +100 respectively. Twenty-four patients were designated as standard risk and twenty-seven patients with more advanced leukaemia were designated as high risk. Median recipient age was 38 years (range 10-56). Median (range) of CD34(+) and CD3(+) cell transplant doses were 4.6 (2.3-10.9) x 10(6)/kg and 0.83 (0.38-2) x 10(5)/kg respectively. The cumulative probability of acute GVHD was 39%. No patient died from GVHD or its consequences. The probability of developing chronic GVHD was 54% (18% extensive). The probability of relapse was 12% for the standard-risk patients and 66% for high-risk patients. In multivariate analysis, the risk factors for lower disease-free survival and overall survival were high-risk disease, CD34(+) dose < 4.6 x 10(6)/kg and CD3(+) dose < 0.83 x 10(5)/kg. Predictive factors for chronic GVHD were a T-cell dose at transplant > 0.83 x 10(5) CD3(+) cells/kg. These results further define the impact of CD34 and CD3 cell dose on transplant outcome and show that careful dosing of stem cells and lymphocytes may permit the control and optimization of transplant outcome.

Adolescent↗

Dosimetric considerations in radiation therapy of coin lesions of the lung.

PURPOSE: The dose distribution in small lung lesions (coin lesions) is determined by the combined effects of reduced attenuation and electronic disequilibrium. The magnitude of the dose delivered also depends on the algorithm used to correct for reduced lung density. These effects are investigated experimentally and computationally for 10 MV photons. METHODS AND MATERIALS: Using a polystyrene miniphantom embedded in cork or cedar, thermoluminescent dosimetry and film dosimetry was performed to investigate interface effects and the central dose per monitor unit (MU). Three frequently applied calculation techniques--no density correction, ratio of tissue maximum ratios (TMRs), and the Batho correction--were also used to calculate the dose per MU. The measurements and calculations were compared with a one-dimensional phenomenological theory with parameters taken from the literature. RESULTS: The measurements at the entrance surface and center of the miniphantom agreed well with the predictions of the phenomenological theory. The interface regions are usually thin enough (2-3 mm) to be clinically unimportant for 10 MV. Depending on the algorithm used to correct for decreased lung density, the lesion dose may be larger or smaller than the prescribed dose by as much as 20% in extreme cases. A clinical example is presented. CONCLUSIONS: In comparing clinical results of treatments of small lung lesions, it is important to be aware of the density correction used.

Aged↗

A new fiducial alignment system to overlay abdominal computed tomography or magnetic resonance anatomical images with radiolabeled antibody single-photon emission computed tomographic scans.

BACKGROUND: The use of computed tomography (CT) or magnetic resonance (MR) to overlay or register uptake patterns displayed by single-photon emission computed tomography (SPECT) with specific underlying anatomy has the potential to improve image interpretation and decrease diagnostic reading errors. The authors have developed a method that will allow the selection of a region of interest on MR or CT images that correlates with SPECT antibody images from the same patient. This method was validated first in phantom studies and subsequently was used on three patients with suspected colorectal carcinoma. METHODS: Two patients were injected with the technetium-99m-labeled 88BV59 immunoglobulin G human antibody, and the third patient was injected with the iodine-131-labeled 16.88 immunoglobulin M human antibody. CT or MR scans were obtained before antibody infusion, and subsequent SPECT scans were obtained on the first or fourth day after infusion. A customized body cast with landmarks was used for each patient during the CT, MR, and SPECT scans to match slice positions for all scanning modalities. Corresponding fiducial landmarks were identified on axial images. A computer graphics program was written to match and overlay corresponding landmarks for each imaging modality. The image registration accuracy was measured by comparing fiducial marker separations (center to center) on the registered scans. This separation uncertainty was 1-2 mm for CT-MR and 3-4 mm for CT-SPECT phantom studies. RESULTS: For patient studies, the fiducial alignment uncertainty was 3-4 mm for axial CT-SPECT and MR-SPECT images, and 6-8 mm for sagittal CT-SPECT and MR-SPECT images. The accuracy of the anatomic alignment of the patient and image registration system was +/- 1 cm in the medial-lateral axis and +/- 2 cm in the cranial-caudal direction. CONCLUSIONS: This type of image analysis may resolve uncertainties with the anatomic correlation of SPECT images that otherwise may be regarded as questionable when SPECT is used alone for radioimmunodiagnosis.

Colorectal Neoplasms↗