PubMed Health⌕ Search

Biomedical subjects

R Andreoli

Publications and source records attributed to R Andreoli.

At least 19 recordsLinked to original sources

Comparison between exhaled and sputum oxidative stress biomarkers in chronic airway inflammation.

The aim of the present study was to compare aldehyde levels resulting from lipid peroxidation in exhaled breath condensate (EBC) and induced sputum (IS) supernatant of subjects with asthma and chronic obstructive pulmonary disease (COPD). Aldehydes (malondialdehyde (MDA), acrolein, n-hexanal (C6), n-heptanal (C7), n-nonanal (C9), 4-hydroxynonenal (HNE) and 4-hydroxyhexenal (HHE)) in both biological fluids were measured by liquid chromatography-tandem mass spectrometry. MDA concentrations in sputum were 132.5 nM (82.5-268.8) and 23.7 nM (9-53.7) in EBC. Similarly, C6, C7 and C9 concentrations in IS were 1.5-4.7-fold higher than in EBC. Acrolein levels were 131.1 nM (55.6-264.6) in IS and 45.3 nM (14.4-127.1) in EBC. The concentrations of HNE and HHE in IS were not significantly different from the levels in EBC. Aldehyde levels in EBC did not show any correlation with aldehyde levels in IS or with differential sputum cellular count. In COPD, MDA in EBC, but not its IS counterpart, was negatively correlated with the severity of disease. In conclusion, the data presented here show that aldehydes can be detected in both exhaled breath condensate and supernatant of induced sputum, but that their relative concentrations are different and not correlated with each other. Therefore, with regard to lipid peroxidation products, exhaled breath condensate and induced sputum must be considered as independent techniques.

Adult↗

Polymorphism of xenobiotic-metabolizing enzymes and excretion of styrene-specific mercapturic acids.

The role of polymorphic xenobiotic-metabolizing enzymes in the interindividual variability of phenylhydroxyethyl mercapturic acids (PHEMAs) was investigated in 56 styrene-exposed workers. Ambient monitoring was carried out using passive personal samplers (geometric mean, 157 mg/m3 8-h time-weighted average; geometric standard deviation, 2.90). Biomonitoring was based on mandelic acid and phenylglyoxylic acid in urine spot samples collected at the end of the work shift ("end-of-shift") and prior to the subsequent shift ("next morning"). Four PHEMA diastereoisomers, namely (R,R)-M1, (S,R)-M1, (S,R)-M2, and (R,R)-M2, were determined by HPLC/tandem mass spectrometry. The genotypes of glutathione S-transferases M1-1 (GSTM1), T1-1 (GSTT1) and P1-1 (GSTP1), and microsomal epoxide hydrolase (EPHX) were characterized by PCR-based methods. Workers bearing the GSTM1pos genotype showed PHEMA concentrations five and six times higher (in end-of-shift and next-morning samples, respectively) as compared to GSTM1null people. In GSTM1pos subjects, (R,R)-M1 was the main mercapturate affected by the GSTM1 status, accounting for 54 and 68% of total PHEMAs in end-of-shift and next-morning samples, respectively. Compared to GSTM1null, GSTM1pos subjects excreted more -M1 than -M2 and more (R,R)-M1 and (S,R)-M2 than (S,R)-M1 and (R,R)-M2 diastereoisomers. Thus, GSTM1-1 is the main isoenzyme catalyzing GSH-conjugation of styrene-7,8-oxide in humans and it seems to act in a regio- and stereoselective way. PHEMAs cannot be recommended as biomarkers of exposure to styrene, unless the GSTM1 genotype is considered in data interpretation. Their role as biomarkers of susceptibility deserves further studies.

Acetylcysteine↗

Liquid chromatography-electrospray tandem mass spectrometry of acidic monoamine metabolites.

A new method based on liquid chromatography-tandem mass spectrometry has been developed for the determination of monoamine metabolites, i.e., homovanillic acid (HVA), vanilmandelic acid (VMA), 3,4-dihydroxyphenylacetic acid (DOPAC) and 5-hydroxyindoleacetic acid (5-HIAA) in human urine. Analytes were separated on a C16 amide (5 cm, 5 microm) column and ionized by negative ion electrospray. Operating in the selected-reaction monitoring mode, linearity was established over three-orders of magnitude and limits of detection were in the range 30-70 microg/l. Precision calculated as RSD was within 0.8-5.2% for all intra- and inter-day determinations. The method was applied to the quantitative analysis of monoamine metabolites in 700 urine samples from occupationally (adults) and environmentally (both children and adults) exposed people living in areas with different soil contamination from lead. The urinary excretion of monoamine metabolites was significantly higher (P<0.001) in the subgroup of children living in polluted areas as compared to the control group (HVA, 6.03 vs. 4.57 mg/g creatinine; VMA, 5.33 vs. 4.37 mg/g creatinine; 5-HIAA 3.24 vs. 2.45 mg/g creatinine). In adults belonging to both groups of subjects occupationally and environmentally exposed, no differences were detected in the urinary concentration of monoamine metabolites. However, adults showed lower values of HVA (2.57 mg/g creatinine), VMA (2.17 mg/g creatinine) and 5-HIAA (2.09 mg/g creatinine) as compared to children groups.

Adult↗

A new method for the analysis of styrene mercapturic acids by liquid chromatography/electrospray tandem mass spectrometry.

A new method based on liquid chromatography/tandem mass spectrometry has been developed for the direct determination of specific urinary mercapturic acids arising from the conjugation of (R)-and (S)-enantiomers of styrene 7,8-oxide with glutathione (GSH), i.e. (R,R)- and (S,R)-N-acetyl-S-(1-phenyl-2-hydroxyethyl)cysteine (R,R-M1 and S,R-M1) and (R,R)- and (S,R)-N-acetyl-S-(2-phenyl-2-hydroxyethyl)-cysteine (R,R-M2 and S,R-M2). The four diastereoisomers were separated on a C18-DB (7.5 cm, 3 microm) column using variable proportions of 20 mM aqueous ammonium formate buffer and methanol at a flow-rate of 0.5 mL/min. The analytes were ionized by electrospray, in negative-ion mode. Operating in selected-reaction monitoring mode, linearity of the MS response versus analyte concentration was established over 4 orders of magnitude, the detection limits being 0.7-1.0 microg/L for all the mercapturates. Precision of the method determined at 50 microg/L (n = 12), expressed as relative standard deviation, was respectively 3.1, 4.8 and 6.9% within the run, intra-day and inter-day. The corresponding figures at 1.0 mg/L (n = 12) were respectively 2.0, 3.6 and 5.5%. The method was applied to the quantitative analysis of conjugated metabolites in urine samples from workers occupationally exposed to styrene. The diastereoisomers R,R-M1 and S,R-M2 accounted respectively for 50 and 40% of total mercapturates, whereas the proportion of R,R-M2 was 7% and only minor amounts of S,R-M1 were detectable. Styrene mercapturates represented a minor fraction of total styrene metabolites, less than 1% on average. The ratio mercapturates/main metabolites (mandelic + phenylglyoxylic acid) showed a bimodal distribution, the medians of the two subgroups being 0.2 and 1%, respectively. Such subgroups are probably characterized by the genetic polymorphisms of the drug-metabolizing enzymes to be identified.

Acetylcysteine↗

Solid-phase microextraction gas chromatographic-mass spectrometric method for the determination of inhalation anesthetics in urine.

Solid-phase microextraction (SPME) has been applied to the headspace sampling of inhalation anesthetics (i.e. nitrous oxide, isoflurane and halothane) in human urine. Analysis was carried out by gas chromatography-mass spectrometry using a capillary column with a divinylbenzene porous polymeric stationary phase. A SPME divinylbenzene-Carboxen-polydimethylsiloxane coated fiber, 2 cm long, was used, and its performances were compared with those of a Carboxen-PDMS in terms of sensitivity, extraction efficiency, extraction time, fiber coating-urine distribution coefficient. For both fibers, linearity was established over four orders of magnitude, limits of detection were below 100 ng/l for nitrous oxide and below 30 ng/l for halogenated. Precision calculated as %RSD was within 3-13% for all intra- and inter-day determinations. The method was applied to the quantitative analysis of anesthetics in the urine of occupationally exposed people (operating room personnel).

Anesthetics, Inhalation↗

Determination of free and glucuronated hexane metabolites without prior hydrolysis by liquid- and gas-chromatography coupled with mass spectrometry.

Since n-hexane metabolites are excreted as glucuronide conjugates, most conventional analytical procedures require preliminary hydrolysis, yielding to the 'total' 2,5-hexanedione (2,5-HD), but also giving rise to a number of artifacts. The whole pattern of n-hexane metabolites, both conjugated and unconjugated, as well as different methods of sample pretreatment have been evaluated by hyphenated techniques (liquid chromatography-mass spectrometry (LC-MS) and gas chromatography-mass spectrometry (GC-MS)). Aliquots of urine from rats exposed to n-hexane underwent enzymatic or acid hydrolysis or both; whereas one aliquot was applied to LC-MS, dichloromethane extracts were analyzed by GC-MS. In untreated urine, four glucuronides (-G) were identified and characterized by LC-MS: 2-hexanol-G, 5-hydroxy-2-hexanone-G, 4,5-dyhydroxy-2-hexanone-G, and 2,5-hexanediol-G. 'Free' 2,5-HD was detectable in non-hydrolyzed samples by both GC- and LC-MS. Whereas enzymatic hydrolysis did not increase the amount of 2,5-HD, acid hydrolysis led to increase 2,5-HD in variable amount and produced gamma-valerolactone as a result of a complete transformation of 4,5-dihydroxy-2-hexanone-G and the partial conversion from 5-hydroxy-2-hexanone-G. Further experiments showed that both 5-hydroxy-2-hexanone-G and 4,5-dihydroxy-2-hexanone-G, isolated by solid-phase extraction and hydrolyzed, yield comparable amount of 2,5-HD and gamma-valerolactone. In samples treated by acid hydrolysis, GC-MS only does not allow to understand the true source of 'total' 2,5-HD, which may be produced not only from 4,5-dihydroxy-2-hexanone-G but also from the more abundant 5-hydroxy-2-hexanone-G, which thus represents the main source of analytical artifacts. 'Free' 2,5-HD seems to be both suitable from an analytical point of view and meaningful for biological monitoring purposes, provided that conjugate metabolites are rapidly removed from the body leading to a negligible neurotoxic risk.

Acids↗

Biomarkers of dose and susceptibility in cyclists exposed to monoaromatic hydrocarbons.

A quasi-experimental field study was carried out in 24 volunteers with the aim of: (i) assessing personal exposure to aromatic hydrocarbons polluting urban areas; and (ii) exploring the role of polymorphic enzymes relevant to the biotransformation of benzene in the inter-individual variability of biomarkers. Each subject covered by bicycle: (i) inner city routes with often jammed traffic; and (ii) open rural routes. Time-weighted average airborne concentrations of benzene, toluene, ethylbenzene and xylenes (BTEX) were determined during 2-h runs. BTEX were determined by solid-phase micro-extraction (SPME) followed by gas chromatography coupled with mass spectrometry (GC-MS) in blood and spot urine samples collected just before and immediately after the runs. Urinary t,t-muconic acid was measured by high performance liquid chromatography (HPLC)-UV. Genotypes of epoxide hydrolase (EH) and glutathione-S-transferase class mu-1 (GSTM1) were also characterised. As compared to pre-run values, benzene and toluene in blood, and toluene and xylenes in urine significantly increased after urban runs. Urinary t,t-muconic acid was significantly higher in post-run samples after both urban (P < 0.001) and rural runs (P < 0.05). Despite a narrow range of exposure levels, a significant relationship was observed between airborne benzene and post-run t,t-muconic acid (r2 = 0.349, P < 0.00). When subgroups were distinguished according to EH and GSTM, subjects bearing both the EH wild type and GSTM 'null' genotype showed significant exposure-related changes in t,t-muconic acid excretion. Even at very low exposure levels, a 2-h bike run in a polluted urban environment may give rise to measurable changes in biomarkers of internal dose of selected aromatic hydrocarbons. Genetically-based metabolic differences may account for part of the inter-individual variability of biomarkers of exposure.

Adult↗

Determination of naphthalene metabolites in human urine by liquid chromatography-mass spectrometry with electrospray ionization.

The use of a liquid chromatography-electrospray mass spectrometry system was investigated for the quantitative analysis of naphthalene metabolites (alpha-naphthol, alpha-naphthylglucuronide and beta-naphthylsulphate) in untreated urine samples. Chromatography was carried out under ion-suppressed reversed-phase conditions, by using high-speed (3 cm, 3 microns) columns and formic acid (2 mM) as a modifier in the mobile phase. The ionization was obtained in the negative-ion mode. Linearity, sensitivity and precision of the method were explored by operating in selected-ion monitoring mode. The method was applied to the quantitative analysis of naphthalene metabolites in untreated urine samples from workers in a naphthalene producing plant. Solid-phase extraction was used for sample clean-up and trace enrichment. Liquid chromatography-tandem mass spectrometry experiments were performed for confirmation purposes.

Calibration↗

Determination of n-hexane metabolites by liquid chromatography/mass spectrometry. 1. 2,5-hexanedione and other phase I metabolites in untreated and hydrolyzed urine samples by atmospheric pressure chemical ionization.

The capabilities of atmospheric pressure chemical ionization liquid chromatography/mass spectrometry (APCI-LC/MS) were investigated for the analysis of urinary 2,5-hexanedione (2,5-HD) and for the identification and characterization of other n-hexane Phase I metabolites in hydrolized urine samples. Chromatography was performed under reversed phase conditions at 0.75 mL min-1 flow rate. The ionization of 2,5-HD and other n-hexane metabolites was obtained in positive ion mode. After optimization of several interface parameters, the linearity, sensitivity and precision of the method were determined operating in the selected ion monitoring mode. Detection limits were 0.02 and 0.05 mg L-1 in water and urine respectively, with linear calibration curves in the 0.05-10 L-1 concentration range. Repeatability and both intra-day and inter-day precision were determined at two concentration levels (0.5 and 5.0 mg L-1), and relative standard deviations were in the 1.3%-5.3% range. The method was applied to the quantitative analysis of 2,5-HD in urine samples from an external Quality Assurance Programme for Organic Solvent Metabolites. Moreover, the metabolites 5-hydroxy-2-hexanone, 2,5-hexanediol and 4,5-dihydroxy-2-hexanone were identified and confirmed in hydrolyzed urine of rats exposed to n-hexane.

Air Ionization↗

Determination of n-hexane metabolites by liquid chromatography/mass spectrometry. 2. Glucuronide-conjugated metabolites in untreated urine samples by electrospray ionization.

A liquid chromatography atmospheric pressure electrospray mass spectrometry (ESI-LC/MS) system was evaluated for the identification and characterization of n-hexane conjugated metabolites (glucuronides) in untreated urine samples. Chromatography of glucuronides was obtained under ion-suppressed reversed-phase conditions, by using high-speed (3 cm, 3 microns) columns and formic acid (2 mM) as modifier in the mobile phase. The mass spectrometer was operated in negative ion (NI) mode. For the first time, four glucuronides were identified by ESI-LC/MS in untreated urine samples of rats exposed to n-hexane: 2-hexanol-glucuronide, 5-hydroxy-2-hexanone-glucuronide, 2,5-hexanediol-glucuronide and 4,5-dihydroxy-2-hexanone-glucuronide. Confirmation of the conjugated metabolites was obtained by LC/MS/MS experiments. Gas chromatography/mass spectrometry (GC/MS) and atmospheric pressure chemical ionization (APCI) LC/MS analyses were performed on the same samples. An integrated approach GC/MS-LC/MS for the semi-quantitative analysis of n-hexane glucuronides, whose standards are not commercially available, is discussed and proposed here. In order to understand the fate of the metabolites during sample pre-treatment, a study about the effects of enzymatic and acid hydrolysis on urine samples was conducted on glucuronides isolated by solid-phase extraction. Combined analyses by GC/MS and LC/MS enabled us to distinguish 'true' n-hexane metabolites from compounds resulting from sample treatment and handling (i.e. enzymatic and acid hydrolysis, extraction and GC injection).

Animals↗

Microhaemorheological properties of binifibrate. Part I: Experimental studies.

The microhaemorheological properties of 3-pyridine carboxylic acid 2-[2-(4-chlorophenoxy)-2-methyl-1-oxopropoxy]-1,3-propanediyl ester (binifibrate, Biniwas), a hypolipidaemic and anti-arteriosclerotic drug composed of two nicotinic radicals and one clofibric radical united by glycerol, were studied. Binifibrate increased passage of a suspension of red blood cells at 80% haematocrit value through filters of 30-40 micron (Teitel's method), and erythrocyte deformability detectable by increase of flow rate through filters of pore size lesser than erythrocyte diameter (Schmid-Schönbein's method). After treatment, resistance to lysis in hypotonic solution is also augmented, indicating that microhaemorheological activity is due to modification of the elastic properties of the erythrocyte membrane.

Animals↗

Microhaemorheological properties of binifibrate. Part II: Preliminary open studies in patients with peripheral arteriopathies.

3-Pyridinecarboxylic acid 2-[2-(4-chlorophenoxy)-2-methyl-1-oxo-propoxy]-1,3-propanediyl ester (binifibrate, Biniwas) an anti-arteriosclerotic and hypolipidaemic agent which showed an effect on microhaemorheological properties during studies in experimental animals (rat and rabbit), was administered to six hyperlipidaemic patients who suffered from circulatory disturbances in the lower limbs. The treatment with binifibrate was applied at a dosage of 3 X 600 mg/day during one month. Both subjective symptoms such as paraesthesia, dysthaesia, coldness at rest and functional weakness of movements were improved, as well as objective symptoms measured by oscillometry. The microhaemorheological analyses demonstrated a positive variation in relative parameters. The correlation between microhaemorheological parameters and clinical symptoms is discussed.

Adult↗

Matrix effects in quantitative pesticide analysis using liquid chromatography-mass spectrometry.

Combined liquid chromatography-mass spectrometry using electrospray or atmospheric-pressure chemical ionization has become an important tool in the quantitative analysis of pesticide residues in various matrices in relation to environmental analysis, food safety, and biological exposure monitoring. One of the major problems in the quantitative analysis using LC-MS is that compound and matrix-dependent response suppression or enhancement may occur, the so-called matrix effect. This article reviews issues related to matrix effects, focusing on quantitative pesticide analysis, but also paying attention to expertise with respect to matrix effects acquired in other application areas of LC-MS, especially quantitative bioanalysis in the course of drug development.

Artifacts↗