PubMed HealthSearch

Biomedical subjects

R B Pelzner

Publications and source records attributed to R B Pelzner.

7 recordsLinked to original sources

Use of glass ionomers as retrofilling materials.

Many materials have been used as retrofillings. Because of the bonding property of glass ionomer cement, this study was conducted to evaluate its possible use as a retrofilling material. Seventy human maxillary anterior teeth were chosen. The root canal systems were cleansed and shaped, and the teeth were assigned to six groups of 10 each. The root canals were obturated with gutta-percha and Grossman sealer, and the apical 2 mm of each root was resected. In all groups a retrofilling preparation was made to a depth of a number 331 bur. The apical preparations were filled in the following manner: silver amalgam (group I), silver amalgam plus two layers of varnish (group II), Ketac-Silver plus two layers of varnish (group III), Ketac-Silver without varnish (group IV), Ketac-Fil plus two layers of varnish (group V), Ketac-Fil without varnish (group VI), and Ketac-Bond (group VII). All the root surfaces with the exception of 2 mm from the resected line were coated with two layers of clear varnish. All the teeth were immersed in methylene blue for 24 hours. After vertical sectioning, dye penetration was measured under a dissecting microscope. The mean apical leakage (in millimeters) was as follows: I = 0.57, II = 0.39, III = 0.22, IV = 0.54, V = 0.11, VI = 0.46, and VII = 0.17. One-way analysis of variance performed on the group means indicated that Ketac-Fil with varnish (group V) and Ketac-Bond (group VII) had significantly less leakage than other groups (p less than 0.05). This study indicates that Ketac-Fil and Ketac-Bond may have potential as retrofilling materials.

Cermet Cements

Human blood pressure and pulse rate response to racemic epinephrine retraction cord.

1. The pulse rate of patients after application of racemic epinephrine-impregnated retraction cords depends more on the level of anxiety and stress than on the level of the epinephrine. 2. Blood pressure is elevated by placement of racemic epinephrine-impregnated retraction cords upon an exposed vascular bed or lacerated tissue. 3. Four percent racemic epinephrine-impregnated retraction cords cause less elevation of blood pressure than 8% racemic epinephrine cords. 4. Although the elevations in blood pressure from 8% cord occur within a narrow range, this range may be hazardous to cardiac patients. Therefore, 4% racemic epinephrine cord should be used. 5. A desirable amount of tissue retraction is produced by 4% racemic epinephrine cord. 6. Dry cords do not provide adequate retraction of tissue and are contraindicated for tissue-retraction purposes.

Adult

Rationalization of electric pulp-testing methods.

A new electric pulp-testing system, the Testark, was developed in order to assess the potential of a different way of testing pulp sensitivity, thus making this electric pulp test more dependable than the conventional electric pulp-testing method. A study was conducted to evaluate the potential of the Testark system in comparison with a commercially available pulp tester. This pilot study consisted of application of three different desensitizing agents (sodium fluoride, test product. 'A', and test product 'B') to the cervical areas of hypersensitive teeth. The results were recorded with both the Testark and the conventional pulp tester simultaneously, and the sodium fluoride and test product 'B' proved to yield a beneficial effect by desensitizing the teeth after a single application. The level of desensitization with these agents was higher than the level obtained with the test product 'A' paste, which was utilized daily for 14 days. The results obtained with the conventional pulp tester differed by way of interpretation from those obtained with the Testark system. The Testark system proved to be easy to use and highly accurate in the data readings because of its high resolution. The Testark systemwas found to be more dependable than the commerical pulp tester, since it reduced the subjective errors which are inevitable when a commerical pulp tester is used. The Testark system is being developed further, and more studies are being conducted at the present time, in order to assess the full potential of the instrument.

Adult

Laser evaluation of handpiece contamination.

Six different models of ultra-high speed handpieces were evaluated in regard to debris accumulation following cutting through tooth structure. A weight-load machine and a laser particle detector were utilized to evaluate the amount of the debris retained. Amounts of debris accumulated after dry and wet cutting were also evaluated. The effect of simple wiping of the handpieces with alcohol guaze was assessed. The results obtained show that the longer the cutting time, the larger the amounts of debris retained on the handpieces. Dry cutting resulted in smaller amounts of debris entrapped than following wet cutting. The cleaning by wiping with alcohol gauze reduced the amounts of the debris, but is insufficient and cannot be utilized as a single procedure for decontaminating handpieces. The external head design is a cardinal factor in retention of debris: larger but smoother surfaces will retain less debris than smaller but more complicated surfaces. External tubings are debris retention foci.

Clinical Trials as Topic