PubMed HealthSearch

Biomedical subjects

R B Price

Publications and source records attributed to R B Price.

At least 19 recordsLinked to original sources

Effects of changes in articulator settings on generated occlusal tracings. Part I: Condylar inclination and progressive side shift settings.

An occlusal scribing device attached to a fully adjustable articulator was used to generate occlusal tracings. The tracings were analyzed to determine the effect changes in progressive side shift and condylar inclination settings had on molar occlusal morphology. The progressive side shift adjustment affected the cusp height and ridge and groove position, primarily in the nonworking excursion. The condylar inclination adjustment affected the cusp heights in the protrusive and nonworking excursion without affecting the working excursion.

Dental Articulators

Effects of changes in articulator settings on generated occlusal tracings. Part II: Immediate side shift, intercondylar distance, and rear and top wall settings.

An occlusal scribing device attached to a fully adjustable articulator was used to generate occlusal tracings. The tracings were analyzed to determine the effect changes in immediate side shift, intercondylar distance, and rear and top wall settings had on molar occlusal morphology. When ranked from greatest to least effect, a 0.2 mm change in the immediate side shift setting had the greatest effect on the occlusion, whereas a 5-degree change in the rear and top wall settings had the least effect.

Centric Relation

Peel bond strengths of five impression material tray adhesives.

The peel bond strengths of five impression materials and their tray adhesives to a perforated and non-perforated test surface were measured and the results were compared using a one-way ANOVA and Student Newman Keuls Multiple Range Test at p less than or equal to .05 level of significance. The auto-mix addition reaction silicone material Extrude produced the greatest peel bond strengths on both the non-perforated test surface (10.88 kg/cm2), and on the perforated test surface (15.88 kg/cm2). These bond strengths were greater than those obtained from the polysulphide and polyether materials used in the study. Using the perforated test surface significantly increased the peel bond strength for all the materials tested. It was concluded that in order to achieve the maximum adhesive bond, impression trays should be perforated. The greatest peel bond strengths were obtained using Extrude medium-body impression material.

Analysis of Variance

Potential errors when using a computerized pantograph.

This study determined the effect on articulator settings of using an arbitrary hinge axis as compared with the terminal hinge axis in orienting a computerized pantograph on a patient. The effect of an error in measuring the reference plane angle or clutch angle was also determined. Two subjects were pantographed 30 times by using the terminal hinge axis and 30 times by using the arbitrary hinge axis. Statistically the articulator settings obtained by using the arbitrary hinge axis and the terminal hinge axis were different, but the difference was small. One subject was pantographed on 18 occasions by using different reference plane angle and clutch angle settings. Analysis showed that 1-degree change in the reference plane angle setting produced approximately 0.9-degree change in the protrusive and orbiting path articulator settings. A 1-degree change in the clutch angle setting produced approximately 0.9-degree change in the progressive side shift settings. It was concluded that the terminal hinge axis should be used as the posterior reference point and the reference plane angle and clutch angle should be carefully recorded.

Cephalometry

Resin-bonded bridges for the pediatric patient.

The resin-bonded bridge is a relatively new clinical technique that has had favorable clinical reports. Recently, new materials and techniques have been developed which may improve the retention of resin-bonded bridges. This article reviews recent developments concerning resin-bonded bridges, present a case report, and give practical suggestions regarding the fabrication of resin-bonded bridges.

Adolescent

Evaluation of a digitizer and computer system designed to analyze articulator-generated occlusal tracings.

Occlusal tracings generated on a Denar fully adjustable articulator were photographed, projected, digitized, and stored in a computer data file. These steps were accomplished with sufficient accuracy for clinical analysis. This study demonstrated that appropriately referenced tracing data can be transferred accurately into a machine-readable form. Studies of pantographic tracings for mandibular movements are facilitated by this convenient and accurate method of handling data.

Dental Articulators

A comparison of articulator settings obtained by using an electronic pantograph and lateral interocclusal recordings.

Articulator settings were obtained for two subjects 10 times in a 2-week period by using both a lateral interocclusal record technique and a Pantronic pantograph. The ORB and PSS articulator settings obtained from the two techniques were compared and the following conclusions drawn. 1. Over a 2-week period, the variance in the Pantronic pantograph ORB and PSS articulator settings was less than the variance in the setting obtained by using lateral interocclusal records. For the Pantronic pantograph technique, 95% of any ORB settings were within 2.5 degrees of the Pantronic pantograph mean and 95% of any PSS settings were within 1.9 degrees of the Pantronic pantograph mean. For the interocclusal record technique, 95% of the ORB settings made with interocclusal records were within 11.9 degrees of the mean for one subject and 13.4 degrees of the mean interocclusal records setting for the other subject. For the PSS settings, 95% of the interocclusal record settings were within 10.1 degrees of the mean setting for one subject and 11.6 degrees of the mean interoccusal record setting for the other subject. 2. In adjusting the ORB and PSS articulator settings, the maximum potential occlusal errors that may be produced by using the Pantronic pantograph are smaller than the maximum errors that may be produced in using the lateral interocclusal record technique.

Dental Articulators

Percutaneous angioplasty in clinical management of renovascular hypertension: initial and long-term results.

Between January 1980 and July 1983, percutaneous transluminal angioplasty was attempted on 137 stenotic renal arteries in 100 patients. At termination of follow-up studies (3-39 months, mean of 16 months), 70% of those treated for hypertension had benefited from the procedure. Stenosis secondary to fibromuscular dysplasia responded better than stenosis from arteriosclerosis (85% and 65% of the patients, respectively). Benefit was minimal for those with stenosis of the renal artery ostium or renal insufficiency. Determining levels of renal vein renin before angioplasty is helpful in selecting patients; following angioplasty, this has considerable significance in predicting the success of the procedure.

Adult

Structural and functional heterogeneity in an insect muscle.

Singing muscles of the katydid, Neoconocephalus robustus (Insecta, Tettigoniidae) are neurogenic, yet perform at contraction-relaxation frequencies as high as 212 Hz (Josephson and Halverson, '71). The mechanical and electrical responses of different bands of one of these muscles (the dorsal longitudinal muscle, DLM) has been examined with respect to ultrastructural features of each part which may be related to muscle performance. The DLM is composed of three bands and is innervated by four motoneurones. The cell bodies of three of these motoneurones occur ipsilaterally in the prothroracic ganglion; the cell body of the other motoneurone is contralateral in the mesothoracic ganglion. Three of the motoneurones (as yet unidentified fast axons) initiate extraordinarily fast twitches (rise time equal 7.3 msec, half duration equals 14.3 msec, 25 C), the fourth (an unidentified slower axon) evokes twitches which are considerably slower (rise time equals 18.9 msec, half duration equals 5.10 msec). Whereas the ventral and medial bands of the muscle are innervated only by fast axons (some fibers of the medial band are doubly innervated), the dorsal band is innervated by both a fast axon and the slower axon. A few fibers of the dorsal band are doubly innervated. The structure of fibers from the ventral and medial bands is very similar, with short sarcomeres (4.0 and 4.3 mum, respectively) and thin strap-like myofibrils delineated by well-developed sarcoplasmic reticulum (SR). Twenty-four percent of the volume of ventral band fibers is SR and the diffusion distance from SR to the center of the adjacent myofibril averages 0.083 mum. Twenty percent of the medial band fiber volume is SR, with a diffusion distance of 0.118 mum. Ventral and medial band fibers contain about 40% mitochondria, and 33% myofibrils. The dorsal band fibers have longer sarcomeres (9.5 mum), and only 10% of the fiber volume is SR. The muscle fibrils of the dorsal band are larger and consequently the diffusion distance is greater (0.227 mum) than in the ventral and medial bands. Mitochondria comprise 23% of the volume of dorsal band fibers. Most dorsal band mitochondria are aggregated into distinct clumps. Although some dorsal band fibers are innervated by a fast axon and some by the slower axon, the dorsal band fibers are structurally homogeneous, suggesting that neurotrophic effects are not important in maintaining the structure of dorsal band fibers. The mechanical-electrical performance and ultrastructure of the ventral and medial bands suggest their roll as fast, metabolically active but weak muscles, used in singing; the dorsal band as a slower but stronger muscle, perhaps involved in postural movements of the wing during singing.

Animals