PubMed Health⌕ Search

Biomedical subjects

R B Walker

Publications and source records attributed to R B Walker.

At least 19 recordsLinked to original sources

A stability-indicating high performance liquid chromatographic (HPLC) assay for the simultaneous determination of atorvastatin and amlodipine in commercial tablets.

A simple, rapid, precise and accurate isocratic reversed-phase stability-indicating HPLC method was developed and validated for the simultaneous determination of atorvastatin (AT) and amlodipine (AM) in commercial tablets. The method has shown adequate separation for AM, AT from their associated main impurities and their degradation products. Separation was achieved on a Perfectsil Target ODS-3, 5 microm, 250 mm x 4.6 mm i.d. column using a mobile phase consisting of acetonitrile-0.025 M NaH(2)PO(4) buffer (pH 4.5) (55:45, v/v) at a flow rate of 1 ml/min and UV detection at 237 nm. The drugs were subjected to oxidation, hydrolysis, photolysis and heat to apply stress conditions. The linearity of the proposed method was investigated in the range of 2-30 microg/ml (r=0.9994) for AT and 1-20 microg/ml (r=0.9993) for AM. The limits of detection were 0.65 microg/ml and 0.35 microg/ml for AT and AM, respectively. The limits of quantitation were 2 microg/ml and 1 microg/ml for AT and AM, respectively. Degradation products produced as a result of stress studies did not interfere with the detection of AT and AM and the assay can thus be considered stability-indicating.

Amlodipine↗

Development and validation of a stability-indicating analytical method for the quantitation of oxytocin in pharmaceutical dosage forms.

A single stability-indicating assay for oxytocin (OT) in pharmaceutical dosage forms using gradient elution over 21 min has been reported in the literature. Furthermore, published and compendial methods for the analysis of OT containing dosage forms also involve using HPLC with gradient elution and complicated mobile phases that include hydrophobic ion pairing agents. A simple isocratic and stability-indicating assay was developed and validated. The conditions are as follows, column: Phenomenex C18 Hypersil, 5 microm packing, 4.6 mm x 150 mm with acetonitrile-phosphate buffer (pH 5; 0.08 M) (20:80) as the mobile phase with UV detection at 220 nm The method was found to be specific for OT in the presence of degradation products and chlorbutol (preservative) with an overall analytical run time of 16 min. Accuracy was determined to be 0.77-1.18% bias for all samples tested. Intra-assay precision (repeatability) was found to be 0.22-1.04%R.S.D. while the inter-day precision (intermediate precision) was found to be 1.27-1.68%R.S.D. for the samples studied. The calibration curve was found to be linear with the equation y = 1.81x + 0.02 and a linear regression coefficient of 0.9991 over the range 0.4-12.0 IU/ml. The LOD and the LOQ were determined to be 0.1 and 0.4 IU/ml, respectively. Syntocinon, a commercially available dosage form of OT was assayed resulting in 100.5-106.6% recovery of the label claim and an average of 10.04 IU/ml.

Buffers↗

A stability-indicating high performance liquid chromatographic assay for the determination of orlistat in capsules.

A stability-indicating HPLC method was developed and validated for the quantitative determination of orlistat in capsule dosage forms. An isocratic separation was achieved using a Perfectsil target ODS-3, 250 mm x 4.6 mm i.d., 5 microm particle size column with a flow rate of 0.7 ml/min and using a UV detector to monitor the eluate at 210 nm. The mobile phase consisted of methanol:acetonitrile:trifluoroacetic acid (82.5:17.5:0.01, v/v/v). The drug was subjected oxidation, hydrolysis, photolysis and heat to apply stress conditions. Complete separation was achieved for the parent compound and all degradation products in an overall analytical run time of approximately 15 min with the parent compound orlistat eluting at approximately 9 min. The method was linear over the concentration range of 0.02-0.75 mg/ml (r = 0.9998) with a limit of detection and quantitation 0.006 and 0.02 mg/ml, respectively. The method has the requisite accuracy, selectivity, sensitivity and precision to assay orlistat in capsules. Degradation products resulting from the stress studies did not interfere with the detection of orlistat and the assay is thus stability-indicating.

Anti-Obesity Agents↗

Generic substitution: the use of medicinal products containing different salts and implications for safety and efficacy.

In their quest to gain early entry of new generic products into the market prior to patent expiration, one of the strategies pursued by generic drug product manufacturers is to incorporate different salts of an approved active pharmaceutical ingredient (API) in a brand company's marketed dosage form and subject such dosage forms to bioequivalence assessment. These initiatives present challenges to regulatory authorities where the decision to approve bioequivalent products containing such pharmaceutical alternatives must be considered in the light of safety and efficacy, and more particularly, with respect to their substitutability. This article describes the various issues and contentions associated with the concept of pharmaceutical alternatives, specifically with respect to the uses of different salts and the implications for safety, efficacy and generic substitution.

Animals↗

An LC-MS-MS method for the determination of cyclizine in human serum.

Cyclizine is a piperazine derivative with anti-emetic activity that is useful in the prevention and treatment of nausea and vomiting associated with motion sickness. A liquid chromatography-tandem mass spectrometry (LC-MS-MS) method is presented for the quantitation of cyclizine in serum. Sample pretreatment involved liquid-liquid extraction of 200 microl of serum with dichloromethane after the addition of 100 microl each of ammonium hydroxide and internal standard solutions. The extracts were analyzed by HPLC on a Luna C18 reversed-phase column and an ion-trap mass spectrometer with an electrospray interface. A limit of detection of 1 ng/ml was determined which allowed for the reliable measurement of cyclizine in the serum of human subjects. The method was found to be linear over the calibration range of 2.5-100 ng/ml. The applicability of this method was demonstrated by the analysis of serum obtained from a human volunteer following administration of a single 50 mg cyclizine hydrochloride tablet. The reported method was observed to have the necessary sensitivity, selectivity, precision and accuracy for monitoring cyclizine concentrations in human subjects following oral administration.

Calibration↗

A capillary zone electrophoresis (CZE) method for the determination of cyclizine hydrochloride in tablets and suppositories.

Current compendial methods of assay for the analysis of cyclizine tablets involve the use of UV spectrophotometry. Since this is a non-selective technique its application to more complex dosage forms, such as suppositories, is unlikely to be appropriate. There is therefore a need for the development of a highly specific quantitative analytical method, such as high performance liquid chromatography (HPLC) or capillary electrophoresis (CE). The latter technique was chosen in view of some specific advantages over HPLC, such as the use of relatively non-toxic aqueous buffers, as opposed to organic solvents, which obviates the use of expensive HPLC grade solvents making CE more cost effective. Cyclizine was analyzed in 50mM phosphate buffer (pH 2.3) and run at an applied voltage 25 kV. Detection sensitivity was enhanced by using a wavelength of 200 nm and samples were loaded hydrodynamically onto an uncoated fused-silica capillary (60 cm x 50 mm i.d.). Chlorcyclizine was used as the internal standard and resolution of both compounds was achieved in less than 7 min. Stress testing was undertaken in order to investigate the appearance of breakdown products. The method has the requisite accuracy, selectivity, sensitivity and precision to assay cyclizine in tablets and suppositories. Degradation products resulting from the stress studies did not interfere with the detection of cyclizine and the assay is thus stability-indicating.

Antiemetics↗

The effect of variations in pH and temperature on stability of melatonin in aqueous solution.

Melatonin (N-acetyl-5-methoxytryptamine) has a diverse range of functions, including the control of neuroendocrine events. A number of studies have shown that melatonin may be of potential benefit for the treatment of insomnia, as well as neurodegenerative disorders. At present, there are numerous dosage forms of melatonin, with the oral route of administration being most popular. Presently, there is little information on the stability of melatonin over a pH range. With the changes in pH in the gastro-intestinal tract, as well as in different experimental conditions, information on the stability of melatonin would be important. We used a high-performance liquid chromatography method to determine the stability of melatonin solutions over a pH range (1.2-12) at room temperature and at 37 degrees C over a period of 21 days. The results show that no melatonin degradation occurred in the first 2 days. From days 3 to 21, there was a gradual decline in melatonin at all pHs, with the decline not exceeding 30%. No decline in melatonin levels occurred in the first 2 days at 37 degrees C. From days 3 to 21, melatonin levels declined gradually, with the decline not exceeding 29%.

Administration, Oral↗

A sensitive and reliable method for the detection of lipid peroxidation in biological tissues.

A simple, accurate and cost effective method has been designed for the determination of lipid peroxidation in biological tissue samples. The method was a modification and improvement on existing methods available for lipid peroxidation determination. Solid-phase extraction was used to separate the thiobarbituric acid-malondialdehyde complex from thiobarbituric acid-reactive substances and HPLC was performed using a C18 (Waters Spherisorb, 5 microm, 250 x 4.6 mm i.d.) column to achieve isolation of the complex. The procedure was validated with respect to linearity of calibration (0.998), precision, sensitivity and limits of quantitation (1 nmol mL(-1)) and detection (0.5 nmol mL(-1)). Resorcinol was used as an external standard. The method was tested by inducing free radical generation with a known free radical generator, quinolinic acid, in rat brain homogenate. The results showed that the method presented allowed detection of lipid peroxidation products at concentrations in the nanomolar (nM) range compared with the micromolar (microM) range detected by other methods, thus rendering it suitable for use with biological samples. In addition, the modified method allowed for detection of the purified lipid peroxidation products, thus eliminating the possibility of simultaneous detection of impurities that absorb at the same wavelength.

Animals↗

Cyanide-induced free radical production and lipid peroxidation in rat brain homogenate is reduced by aspirin.

The neuroprotective properties of aspirin were investigated using cyanide-induced neurotoxicity as model. Cyanide, a known neurotoxic agent significantly increased lipid peroxidation and superoxide anion levels in rat brain homogenate in a concentration-dependent manner (0.25-1.0 mM). When homogenate, containing 1.0 mM KCN was co-treated with aspirin (1.0 mM) there was a significant decrease in lipid peroxidation. Aspirin (0.5 mM and 1.0 mM) also significantly reduced KCN-induced superoxide anion generation. The results of the present report therefore indicate a neuroprotective role for aspirin.

Animals↗

An investigation into the neuroprotective properties of ibuprofen.

There is increasing evidence suggesting a protective role for anti-inflammatory medications in neurological disorders such as Alzheimer's disease (AD). While there has not been any direct evidence for this, a number of clinical studies indicate that those patients who have had a history of nonsteroidal anti-inflammatory use, have a lower incidence of AD. Since there is currently no evidence on the mechanism by which these agents offer possible neuroprotection, we investigated the potential neuroprotective properties of the nonsteroidal anti-inflammatory drug, ibuprofen, by examining whether this agent could reduce lipid peroxidation and superoxide radical generation. Quinolinic acid and cyanide, known neurotoxins, were used to induce lipid peroxidation and superoxide anion formation respectively, in rat brain homogenate. The results show that ibuprofen significantly (p<0.05) reduced quinolinic acid-induced lipid peroxidation and cyanide-induced superoxide production. The results of the present report therefore suggest a possible mechanism for the neuroprotective effect of ibuprofen.

Animals↗

Analysis of macrolide antibiotics.

The following macrolide antibiotics have been covered in this review: erythromycin and its related substances, azithromycin, clarithromycin, dirithromycin, roxithromycin, flurithromycin, josamycin, rokitamycin, kitasamycin, mycinamycin, mirosamycin, oleandomycin, rosaramicin, spiramycin and tylosin. The application of various thin-layer chromatography, paper chromatography, gas chromatography, high-performance liquid chromatography and capillary zone electrophoresis procedures for their analysis are described. These techniques have been applied to the separation and quantitative analysis of the macrolides in fermentation media, purity assessment of raw materials, assay of pharmaceutical dosage forms and the measurement of clinically useful macrolide antibiotics in biological samples such as blood, plasma, serum, urine and tissues. Data relating to the chromatographic behaviour of some macrolide antibiotics as well as the various detection methods used, such as bioautography, UV spectrophotometry, fluorometry, electrochemical detection, chemiluminescence and mass spectrometry techniques are also included.

Animals↗

Effect of hydroxypropyl-beta-cyclodextrin on the central stimulant activity of (-)-ephedrine and an oxazolidine prodrug in rats.

1. Hydroxypropyl-beta-cyclodextrin (HP-beta-CD) increases the stability of the oxazolidine prodrug toward hydrolysis. 2. The binding constant (Kb) and rate constant (Kc) for the hydrolysis of the prodrug-HP-beta-CD complex were calculated from the kinetic data. 3. Ion-spray mass spectra confirmed prodrug-HP-beta-CD complexation. 4. Mass spectral and kinetic data indicated 1:1 stoichiometry for the complex. 5. A significant elevation of locomotor activity in rats was observed when either (-)-ephedrine or the prodrug was administered by either the intraperitoneal or the oral route. 6. Addition of HP-beta-CD potentiated the central nervous system effect of both (-)-ephedrine and the prodrug when administered intraperitoneally. However, when the drugs were administered orally, HP-beta-CD caused a decrease in activity.

2-Hydroxypropyl-beta-cyclodextrin↗

Analysis of chromameter results obtained from corticosteroid-induced skin blanching. I: Manipulation of data.

PURPOSE: One of the unresolved issues in the FDA Guidance document for topical corticosteroid bioequivalence testing is the method of manipulation suggested for the chromameter data. The purpose of this study was to manipulate the instrumental data from a typical blanching study in a number of ways to investigate the appropriateness of these procedures for comparison with the subjective visually-assessed results. METHODS: The human skin blanching assay methodology routinely practiced in our laboratories was utilised and the vasoconstriction produced by two corticosteroid formulations of different potency was assessed visually and instrumentally by use of a Minolta chromameter. The instrumental data were corrected for zero-time and unmedicated site readings. In addition, Euclidean distances were calculated using all data generated by the instrument. RESULTS: Individually the a-, b- and L-scale chromameter values are imprecise and there is negligible vasoconstriction response recorded for the moderately potent formulation. Arithmetical manipulation of the data as suggested by the FDA does not appear to improve the quality of the data in any way. Euclidean distance analysis more closely resembles the visual data and appears to have better precision. CONCLUSIONS: It is clear that mathematical correction of chromameter data is unnecessary, especially since the instrumental data are extremely imprecise. Furthermore, the assessment of each individual chromameter index does not adequately characterise the blanching response profile. It is therefore suggested that Euclidean distance may be a better measure on which to base an analysis of bioequivalence than the truncated data set methodology currently suggested by the FDA.

Adrenal Cortex Hormones↗

In vitro release of amoxycillin from lipophilic suppositories.

The in vitro release characteristics of amoxycillin from different lipophilic suppository bases were investigated using the USP rotating basket method. Suppositories containing 250 mg amoxycillin were prepared in theobroma oil and in the semi-synthetic bases Witepsol W35, Suppocire A32, Novata BD, and Novata 299. Both freshly prepared and 1-month-old suppositories were tested. Analysis of amoxycillin was performed using a validated high-performance liquid chromatographic (HPLC) technique. Release profiles differed significantly between bases, with the greatest amount of amoxycillin being released from both newly made and 1-month-old Novata BD bases (87.57 +/- 8.18 and 99.66 +/- 6.63%, respectively), and the lowest amount released from the newly manufactured theobroma suppositories (8.82 +/- 0.75%) and the 1-month-old Suppocire A32 suppositories (7.78 +/- 0.27%).

Amoxicillin↗

Effect of cyclodextrins on the hydrolysis of an oxazolidine prodrug of (1R,2S)-(-)-ephedrine-cis-2-(4-methoxyphenyl)-3, 4-dimethyl-5-phenyloxazolidine.

Molecular complexes of an oxazolidine prodrug of (-)-ephedrine, cis-2-(4-methoxyphenyl)-3,4-dimethyl-5-phenyloxazolidine, with alpha-, beta-, dimethyl-beta- (DM-beta-) and hydroxypropl-beta- (HP-beta-) cyclodextrins (CDs) were examined using ionspray mass spectrometry. The results suggest, under our experimental conditions, a 1:1 stoichiometric complex between the prodrug and all CDs. Apart from the putative inclusion complexation, the stabilization effect of CDs on the prodrug in an aqueous solution was studied. beta-, DM-beta- and HP-beta-CD exhibited a retardation effect on the rate of hydrolysis of the prodrug. Conversely, alpha-CD did not alter the rate of hydrolysis even at excess concentrations. Presumably, the larger cavity diameter of beta-CDs may permit a greater depth of penetration of the prodrug, resulting in its shielding from hydrolysis. The observations in this work indicate that mass spectrometry could be a rapid and informative analytical method to aid in the preliminary evaluation of the potential utility of CDs in enhancement of drug stability.

Cyclodextrins↗

Evaluation of the proposed FDA pilot dose-response methodology for topical corticosteroid bioequivalence testing.

PURPOSE: The American FDA has recently released a Guidance document for topical corticosteroid bioequivalence testing. The purpose of this study was to evaluate the recommendations of this document for appropriateness. The new specifications require a dose-vasoconstriction response estimation by the use of a Minolta chromameter in a preliminary pilot study to determine the parameters for use in a pivotal bioequivalence study. METHODS: The visually-assessed human skin balancing assay methodology routinely practiced in our laboratories was modified to comply with the requirements of the pilot study so that visual and chromameter data could be compared. Two different cream formulations, each containing 0.12% betamethasone 17-valerate, were used for this comparison. RESULTS: Visual data showed the expected rank order of AUC values for most dose durations whereas the chromameter data did not show similar results. The expected rank order of AUC values for both chromameter and visual data was not observed at very short dose durations. In fitting the data to pharmacodynamic models, equivalent goodness of fit criteria were obtained when several different parameter estimates were used in the model definition, however the visual data were best described by the sigmoid Emax model while the chromameter data were best described by the simple Emax model. CONCLUSIONS: The Emax values predicted by the models were close to the observed values for both data sets and in addition, excellent correlation between the AUC values and the maximum blanching response (Rmax) (r > 0.95) was noted for both methods of assessment. The chromameter ED50 values determined in this study were approximately 2 hours for both preparations. At this dose duration the instrument would not be sensitive enough to distinguish between weak blanching responses and normal skin for bioequivalence assessment purposes.

Administration, Topical↗

The ecosystem study on Rongelap Atoll.

During the 1950's and 1960's, the Laboratory of Radiation Biology at the University of Washington carried out an intensive study of this Atoll, which was contaminated with radioactive fallout from the "Bravo shot" in 1954. This study involved many aspects of the environment and the plant and animal life: soils, land plants, marine life, birds, geology and hydrology, and human diets as well. In much of the research, the fortuitiously present radioactive isotopes, especially 137Cs and 90Sr, were tracers. Although the term "ecosystem study" was not in vogue at that time, it is clear that this was an early use of the ecosystem approach. Soil types and their development, the distribution of mineral elements in plants and soils, including predominant radionuclides, distribution and growth of native terrestrial plants in relation to topography and salinity, some aspects of the human diets, micronutrient nutrition of the coconut palm, island and islet development and stability, were given attention in the studies. Some of the findings in the various areas of study will be presented and discussed.

Animals↗