[Impact and risks of cost cutting programs on the quality of hospital care in Switzerland].

Cost-minimization programs in Switzerland either in the public or the private sector have impact on quality and accessibility of the health care system. Rationalization may induce in fact hidden rationing of care and increases the workload of the health care workers involved. The relation of hospital staffing to inpatient quality of care are important issues. The reduction of funds may place patients at risk, due to lower staffing levels. Patient to nurses ratio have a substantial effect on inpatient mortality and nurse burnout. Research in Switzerland is needed to define the measurement of the nursing case mix on the basis of discharge data and to elucidate the factors influencing the staffing levels of nurses and the mix of nursing personnel in hospitals. Due to reduced funding the ability of hospitals to handle emergency cases may be compromised. The impact on quality and risks of unreflected cost minimization programs in hospitals but also the whole health care system are important and worth of public notice. Possible solutions for a health care reform in Switzerland are outlined and discussed.

Cost Control↗

Locking compression plate loosening and plate breakage: a report of four cases.

The Locking Compression Plate (LCP) system offers a number of advantages in fracture fixation combining angular stability through the use of locking screws with traditional fixation techniques. This makes the implant particularly suitable for use in poor bone stock and complex joint fractures, especially in the epimetaphyseal area. However, the system is complex, requiring careful attention to biomechanical principles, and a number of potential pitfalls need to be considered. These pitfalls are illustrated in the 4 cases described herein, in which treatment was unsuccessful due to implant breakage or loosening. In each case, treatment failure could be attributed to the choice of an inappropriate plate and/or fixation technique, rather than to the features of the Locking Compression Plate system itself. Such experiences highlight the importance of detailed understanding of the biomechanical principles of plate fixation as well as careful preoperative planning for the successful use of the Locking Compression Plate system.

Aged↗

[New concepts for stabilizing proximal humeral fractures].

The treatment of proximal humerus fractures is overshadowed by problems like avascular humeral head necrosis, implant failure in osteopenic bone and moderate outcome, especially in the elderly. More precise imaging, a better understanding of the vascularity of the humeral head leading to indirect reduction techniques and new implants which allow for saver fixation even in osteopenic bone, allowing early functional aftercare, are the new promising factors which have the potential to ameliorate fracture treatment of the humeral head. A prerequisit for sucessful treatment is a thoroughful imaging which allows adequate preoperative planning. The type of stabilisation depends more on the surgeons preference and there are pros and cons with all implants. Functional after treatment however depends on the applied stabilisation principle and should be carefully monitored and adapted according to the bone healing process, monitored by regular postoperative x-ray controls.

Aged↗

[New principles in the surgical treatment of distal radius fractures -- locking implants].

The treatment goal for fractures of the distal end of the radius is full functional recovery of the wrist. Prerequisites are restoration of the anatomy and early functional after treatment in accordance to the treatment guidelines for other articular and juxta-articular fractures. A better understanding of the anatomy and new biomechanical models lead to the development of new implants and operative techniques. The LCP-concept with locking screws had a considerable impact on recent advances in the operative treatment of distal radius fractures.

Bone Plates↗

[New minimally invasive methods of stabilizing distal femoral fractures].

New, minimally invasive methods of stabilizing distal femur fractures offer the advantage of superior bone healing rates and lower infection rates despite of a decreased necessity of bone grafts. In comparison to conventional plating, the employed indirect reduction method does not lead to an increase in postoperative malalignments. The Less Invasive Stabilizing System (LISS) and the Distal Femur Nail (DFN) are introduced as examples of these new methods of stabilization. Although bone biology is widely respected by these new implants and operation techniques, distal femur fractures remain a serious injury, often resulting in subnormal function.

Adult↗

[Osteosynthesis of combined radius head and capitulum humeri fractures with mini-implants].

INTRODUCTION: Combined injuries of the capitellum humeri and the radial head are rare. Most of them show combined osteocartilaginous lesions and collateral ligament lesions. Recommendations for treatment of these fatal injuries of the elbow are missing. TYPE OF STUDY: Five cases were investigated in an retrospective analysis. The same approach was used for the osteocartilaginous lesion of the capitellum as well as the injury of the radial head. Internal fixation was done with mini-titanimplants, three of them combined with resorbable pins. PATIENTS AND METHODS: Between 1996-1999 five patients (four men, one woman) with combined injury of the radial head and the capitellum were stabilized. The average age was 34 years (31-40 years). All fractures were stabilized by a direct radial approach with 1.5 mm or 2.0 mm lag screws partly with resorbable pins. All patients were evaluated radiologically and clinically according to the Mayo-elbow-performance score. RESULTS: All patients were personally examined after an average period of 12.8 month (8-24 month) by an independent investigator. 4/5 patients were assessed for their satisfaction. No radiological signs of avascular necrosis of the capitellum or arthrosis were found. Three patients showed periarticular calcifications. The range of motion was averagely 124 degrees (extension 5-30 degrees, flexion 110-145 degrees), in three of five cases a secondary intervention for improvement of joint mobility was necessary. The Mayo-elbow-performance score rated for 85 points in average (range 70-100 points). CONCLUSION: Direct screw fixation with mini-implants, eventually combined with resorbable pins allows to use the same approach for anatomic reconstruction and fixation of the capitellum humeri and radial head. Transarticular fragment fixation of the capitellum allows for safe compression. Therefore early functional rehabilitation is possible postoperatively. Secondary interventions for improve joint motion were necessary in three of five cases.

Absorbable Implants↗

[Management of complex distal radius fractures].

Complex injuries of the distal radius can be associated with articular comminution, severe soft tissue injury, large metaphyseal and/or diaphyseal bone defects, carpal ligament tears or its combinations. We recommend a standardized three step approach for the management of these severe injuries: external fixation as an emergency procedure; treatment of soft tissue damage and further diagnostics as needed; definitive adapted operative therapy after thorough analysis of the specific injury.

Bone Plates↗

[Dorsal double plating for fractures of the distal radius--a biomechanical concept and clinical experience].

This article describes the anatomical and biomechanical rationale for stable internal fixation of distal radius fractures using a dorsal approach. The three column biomechanical model is illustrated. Advances in the understanding of the anatomy, the biomechanical model of the three columns and our clinical experience with dorsal double plating have lead to the development of a new set of precontoured 2.4 mm Titanium plates with the option for head locking screws.

Biomechanical Phenomena↗

[LISS tractor. Combination of the "less invasive stabilization system" (LISS) with the AO distractor for distal femur and proximal tibial fractures].

Minimally invasive plate osteosynthesis (MIPO) in conjunction with the less invasive stabilization system (LISS) first requires reduction and retention of the fracture using such aids as external fixation, distractors, and percutaneous reduction clamps before the plate can be applied. Based on the open indirect "biological" technique of osteosynthesis, the LISS was combined with an AO distractor (LISS tractor) integrated into the LISS plate. This made reduction possible against the plate before final fixation of the LISS plate. The LISS tractor concept was validated in three patients and we present the technique here. No malalignments > 5 degrees occurred. Fluoroscopy lasted 3.0 min (range: 2.1-4.5) and the operation 125 min (range: 90-150). Modification of the well-known LISS technique by integrating the distractor into the LISS plate to simplify reduction and to provide temporary retention of the fracture has the potential to reduce the fluoroscopy time, the operation time, the rate of malalignments, and the learning curve for this MIPO technique.

Aged↗

["Bone tumor" diagnostic error in stress fracture of the medial tibial plateau].

Stress fractures occur in 13.2-37.0% in running athletes. There is a decreasing incidence of these fractures in the tibia (33%), navicular (20%), metatarsus (20%), femur (11%), fibula (7%) and pelvis (7%). Clinically stress fractures present themselves with uncharacteristic local pain under weightbearing conditions. In 75% the medial tibial crest is involved. Usually the pain disappears when the patient is non-weightbearing. As causal factors wrong training methods, oligomenorrhoe (6x incidence), low nutrition input (8x incidence) and a genu recurvatum-morphotype can be found. Misinterpretation can result from a similar clinical and radiological (conventional x-ray, scintigraphy, MRI) early course in stress fractures and bone tumors. We present a patient with a clinical diagnosis of a meniscus lesion. The following MRI was suspect for a malignant lymphoma or histiocytoma. Biopsy was performed and showed the final diagnosis of a stress fracture.

Adult↗

Avascular necrosis of the femoral head after open reduction and internal fixation of femoral neck fractures: an inevitable complication?

Between 1980 and 1989 71 patients with a femoral neck fracture were treated at the University Hospital of Basel by a Dynamic Hip Screw (n = 54) or by three compression screws (n = 17). Fifty out of 71 patients (70%) were reviewed clinically and radiologically after an average of 116 months. 32/50 fractures (64%) had united. In 18/50 (36%) either avascular necrosis (12) or secondary fracture dislocation (6) had resulted in failure after an average of 29 months following injury. Despite these results, the patients assessment had been very good or good in 44 patients (88%) and fair only in six patients (12%). The cause of secondary dislocation proved to be mainly due to a technical failure at surgery. The incidence of avascular necrosis was significantly higher in displaced fractures compared to non-displaced fractures (p < 0.05), regardless of the quality of the reduction achieved (varus or valgus) or the time delay between accident and operation. However it was interesting to note, that more than one third of all avascular necrosis became apparent more than 3 years (4-10 years) after the accident.

Adult↗

Trauma decreases leucine enkephalin hydrolysis in human plasma.

Plasma hydrolysis of leucine enkephalin was evaluated, together with several cellular immune parameters, in a homogeneous group of human subjects who had undergone severe trauma (proximal femur fracture); data obtained were compared with those obtained in an age-matched control group. In the experimental group, immediately after hospitalization, substrate hydrolysis was reduced with respect both to the control subjects and the same patients 4 weeks after the trauma. Chromatographic separation of the enzymes active on leu-enkephalin showed that the reduction of substrate hydrolysis is mainly attributable to the decrease in the activity of enkephalin-degrading enzymes, principally of aminopeptidases, per se, whereas the role of the low-molecular-weight plasma inhibitors is only minor. In the same subjects, several of the immunological parameters measured underwent modifications that may be considered stress related. However, the absence of a quantitative relationship between reduction in hydrolysis and modifications of immune parameters does not support the hypothesis of a direct relationship between these two sets of data.

Aged↗

Age-induced increase of leucine enkephalin enzyme degradation in human plasma.

Possible age-induced variations of the hydrolysis of leucine enkephalin in the presence of plasma enzymes were studied by kinetic and chromatographic techniques in a group of elderly individuals. Results obtained indicate that in elderly individuals the activity of enkephalin-degrading plasma enzymes is greater than in the controls; ANOVA analysis of these data indicates that the dependency of the variation of hydrolysis upon the two age groups is statistically significant. Increased substrate hydrolysis, and a modified hydrolysis pattern, appear to be associated with increased activity of the enzymes involved, and with different distribution of the individual enzymes within each class, as well as with severely reduced activity of the low molecular weight plasma inhibitors. The combination of these factors defines a characteristic hydrolysis pattern for the elderly individuals, different from that found in the controls.

Adult↗

Clinical results using the trochanter stabilizing plate (TSP): the modular extension of the dynamic hip screw (DHS) for internal fixation of selected unstable intertrochanteric fractures.

OBJECTIVE: To evaluate whether the implantation of the modular trochanter stabilizing plate (TSP) in addition to the dynamic hip screw (DHS) prevents excessive telescoping and limb shortening in four-part and selected three-part trochanteric fractures. DESIGN: Prospective clinical study. SETTING: The study was conducted at the trauma unit of the Surgical Department of the University of Basel, Switzerland. PATIENTS: Forty-six consecutive patients with unstable intertrochanteric fractures were treated with an additional TSP super-imposed on the regular DHS at our institution between July 1991 and July 1993. Five patients died before the first follow-up, one patient was lost to follow-up, and another patient refused follow-up. Thus, thirty-nine patients were followed for at least twelve months (mean 14 months, range 12 to 20 months). INTERVENTION: The fractures treated were classified according to the OTA classification, which is based on the AO classification. Seventeen were 31-A2.2, seven were 31-A2.3, and fourteen were 31-A3.3 fractures. RESULTS: Lateralization of the greater trochanter was successfully prevented in all fractures. Limited fracture impaction was found in 90 percent (n = 35) of the patients with telescoping of 9.5 millimeters (range 0 to 30 millimeters), resulting in mean limb shortening of 5.37 millimeters (range 0 to 14.9 millimeters). Four patients suffered limb shortening exceeding fifteen millimeters (range 15.6 to 21.3 millimeters). Functional results were excellent and good in 87 percent of patients and fair in 13 percent according to the Salvati-Wilson score. All fractures had healed six months after the operation. Three complications required a secondary procedure: one from not inserting a second screw parallel to the gliding hip screw to prevent rotation of the head-neck fragment ("antirotation screw"), one because of deep infection, and one because of a refracture after premature implant removal. CONCLUSION: In unstable pertrochanteric fractures with small or missing lateral cortical buttress, the addition of a TSP to the DHS effectively supports the unstable greater trochanter fragment and can prevent rotation of the head-neck fragment. Excessive fracture impaction and consecutive limb shortening was prevented by this additional implant in 90 percent of these patients.

Adult↗

[Small bowel injuries in blunt abdominal trauma--a diagnostic problem!].

AIMS: Injuries of the small bowel following a blunt abdominal trauma are rare (incidence 6%). The diagnosis is difficult and therefore often missed. The aim of this paper is to acquire an useful diagnostic sequence of our own results in comparison to the literature. METHODS: The diagnostic procedures and the time of the final diagnosis of 13 patients with this rare injury have been retrospectively analysed. RESULTS: Two of these 13 patients died in the emergency room. Five of the remaining 11 patients had signs of peritonitis at the first examination. These were confirmed by findings either in peritoneal lavage (3), ultrasound (1) or X-ray (1). Patients without signs of peritonitis revealed no pathological signs at the first examination with these diagnostic tools. Correct diagnosis was achieved on 7/11 patients within 24 hours. The diagnosis of small bowel injury was confirmed by the rest of the patients (n = 4) after an average of 11 days after trauma. DISCUSSION/CONCLUSION: Initial assessment with diagnostic tools as ultrasound, peritoneal lavage or X-ray is poor. Therefore repetitive controls (Nowadays by ultrasound) are indicated. The CT is a valuable tool to detect an organ lesion in hemodynamic stable patients with positive proof of liquid in the ultrasound. Today the value of the diagnostic laparoscopy is not established. It should be considered that a local ischemia due to the blunt trauma can cause a delayed perforation.

Abdomen↗

Generation of lymphokine-activated killer activity in rodents but not in humans is nitric oxide dependent.

The role of nitric oxide (NO) in the generation of lymphokine-activated killer (LAK) cells was investigated. Here we report that L-arginine analog NG-monomethyl-L-arginine (NMMA), a specific inhibitor of nitric oxide synthase, prevents LAK cell generation from cultured rat splenic cells. Accumulated NO endproduct nitrite (NO2-), as measured in the supernatants of rat splenic cells, correlated well with the generation of LAK cells. In contrast, cell proliferation induced by rIL-2 or by Con A was not affected by NMMA. Similarly, phenotypic expression of CD25 in rIL-2-stimulated cultures was unaffected. Furthermore, we could not observe differences in percentages of CD5-CD8+ cells (NK and LAK cell phenotype markers in rats) between rIL-2-stimulated cultures performed in the presence or absence of NMMA. LAK cell generation could no longer be blocked if NMMA was added to the rat cell cultures 24 hr after rIL-2 stimulation. To further confirm the role of NO in LAK cell generation, rat splenic cells were cultured in medium without L-arginine. Under such conditions rIL-2 could not induce LAK cell generation. Hemoglobin, which is a scavenger of NO, also inhibited LAK cell generation. Finally, addition of sodium nitroprusside (SNP) which releases NO in cultures was able to overcome blocking effects of NMMA. To attempt the identification of NO-producing cells, lysosomotropic agent, L-leucine methyl ester (LME), was used. Generation of LAK cell activity was virtually abolished in cell cultures treated with LME. Addition of SNP to cultures, however, sufficed to restore LAK cell generation. These results suggest that LAK cell precursors depend on a exogenous NO supply from other cell types in order to display their full cytotoxic potential. Similar results were also obtained by using mouse splenocytes as responder cells. In contrast, NMMA did not affect generation of LAK cells from human peripheral blood or spleen mononuclear cells.

Animals↗

Glutamine requirements in the generation of lymphokine-activated killer cells.

The role of glutamine (GLN) in the generation of lymphokine-activated killer (LAK) cell activity was investigated. LAK cells were derived from healthy donors and peripheral blood mononuclear cells (PBMC) were obtained using either unseparated PMBC or DR(-) CD3(-) CD16(+) CD56(+) enriched cells. PBMC were cultured for 6 or 10 days in medium supplemented with recombinant interleukin-2 (rlL-2; 100 U/ml) in the presence of different concentrations of GLN. K562 (natural killer-NK-sensitive targets), 1301 and U-937 (NK-resistant targets) cells were used as targets in the cytotoxic assays. Furthermore, the limiting dilution (LD) culture system was applied as an alternative to the bulk cell culture system. It was found that GLN affects the lytic potential of cultured cells while the frequency of responding cells did not significantly differ between the compared cell cultures performed in the presence of different amounts of GLN. Data on cell proliferation with IL-2 stimulation showed significant differences in cultures performed in the presence or absence of GLN. The results of present investigation suggest a supportive role of GLN in the generation of LAK cells. GLN deficit affects LAK cell killing activity by limiting the number of generated effector cells while acquisition of broad-range killing capacity was not affected.

Journal Article↗