PubMed Health⌕ Search

Biomedical subjects

R Bjornerheim

Publications and source records attributed to R Bjornerheim.

9 recordsLinked to original sources

High frame rate Doppler echocardiography in the rat: an evaluation of the method.

AIMS: In small animal models, two-dimensional (2D) and Doppler echocardiography should provide more information than M-mode, especially in animals with infarcted and distorted left ventricles, but has been limited by low frame rates and poor near field resolution. New, high frame rate echo-Doppler equipment with digital processing was tested for accuracy of measurements. METHODS AND RESULTS: Fourteen normal Wistar rats (232-328 g) were examined under halothane anaesthesia. Pulsed Doppler recordings from both left ventricular outflow tract(LVOT) and right ventricular outflow tract (RVOT) cor-responded well with simultaneous ultrasound transit time measurements of aortic flow (LVOT: v=0.99x+4.8, min R=0.93. Standard error of estimate (SEE)=8.3 ml x min(-1), and RVOT: v=0.97x -4.3. R=0.93. SEE =8.4 ml x min(-1). No systematic differences were observed over a flow range of 20-90 ml x min(-1). Left ventricular (LV) dimensions assessed by 2D parasternal long-axis and short-axis views were equal to M-mode measurements with LV diameter 6.6 + 0.44 mm, anterior wall 1.8 +/- 0.18 mm, and posterior wall 1.5 + 0.56 mm. Mean absolute difference 4.4-8.5%. Intra- and interobserver variability was 4.6 +/- 4.1% and 6.7 +/- 7.0% for Doppler measurements, and 4.3 +/- 3.8% and 3.8 +/- 4.6% for dimensions, respectively. CONCLUSION: High frame rate Doppler echocardiography provides accurate non-invasive measurements of cardiac structure and function in the rat.

Animals↗

Echocardiographic criteria for detection of postinfarction congestive heart failure in rats.

We evaluated postinfarction myocardial function in rats and determined echocardiographic criteria for congestive heart failure (CHF) using high performance echocardiography. Extensive myocardial infarction (MI) was induced in rats by left coronary occlusion. Sham-operated animals served as controls. Five weeks later, high-frame rate ( approximately 200 Hz), fully digitized, shallow-focus (10-25 mm), two-dimensional, M-mode and Doppler echocardiography was performed. A J-tree cluster analysis was performed using parameters indicative of CHF. Reproducibility was examined. The cluster analysis joined the animals into one Sham and two MI clusters. One of the MI clusters had clinical characteristics of CHF and elevated left ventricular end diastolic pressure. Among the echocardiographic variables, only posterior wall shortening velocity separated the failing and nonfailing MI clusters. We conclude that, by high frame rate echocardiography, it is possible to obtain high- quality recordings in rats. It is feasible to distinguish MI rats with CHF due to myocardial dysfunction from those without failure and to perform longitudinal studies on myocardial function.

Animals↗

Diastolic flow pattern in the normal left ventricle.

OBJECTIVES: This study sought to clarify the diastolic flow pattern in the normal left ventricle. BACKGROUND: During left ventricular filling, basally directed (retrograde) velocities are seen in the outflow compartment. These velocities may represent blood returned from the apical region or a shortcut at a more basal level. METHODS: Left ventricular flow patterns were identified in 18 healthy individuals (age 47 +/- 12 years) with the use of high frame-rate two-dimensional color Doppler and color M-mode Doppler echocardiography techniques. Intraventricular velocities were measured with single pulsed Doppler at 3 levels in both inflow and outflow compartments (posterolateral and anteroseptal parts of the left ventricle). RESULTS: During early transmitral flow acceleration, all intraventricular velocities were directed towards the apex. However, after peak early and late inflow velocities and during diastasis, retrograde velocities were identified in the outflow compartment. These retrograde velocities occurred earlier, and were higher, at the level of the deflected anterior mitral leaflet tip compared with more apical levels (P <.001). A velocity pattern was established, consistent with early intraventricular vortex formation behind both mitral leaflets. The vortex adjacent to the anterior leaflet subsequently enlarged to include a major part of the left ventricle. CONCLUSION: Uniform diastolic flow patterns were identified in the normal left ventricles. The findings suggest that both early and late diastolic filling start with an initial motion of a fluid column, succeeded by vortex formation, which explains retrograde flow in the outflow compartment.

Adult↗

Reversal of intraventricular flow propagation during isovolumic relaxation: A marker of anterior wall dysfunction.

BACKGROUND: Myocardial infarction induces left ventricular (LV) wall motion abnormalities during isovolumic relaxation (IVR) and may potentially alter intraventricular flow during this period. This study evaluated whether 2-dimensional color Doppler measurements of intraventricular flow during IVR were able to identify LV dysfunction caused by coronary artery disease. METHODS: Patients with single-vessel coronary artery disease and posterior wall infarction (21 patients) or anterior wall infarction (27 patients) were included. Eighteen healthy persons served as a control group. LV function was examined by 2-dimensional echocardiography, 2-dimensional color Doppler, and pulsed Doppler techniques. RESULTS: All normal persons (23.6 +/- 10.9 cm/s) and patients with posterior infarction (19.6 +/- 9.3 cm/s) had flow propagation towards LV apex during IVR. Patients with anterior wall infarction had reversed flow direction (-12.2 +/- 8.7 cm/s, P <.001). The echocardiographic wall motion score index of the 4 apical segments correlated well with flow velocities (r = -0.78, P <.001). CONCLUSION: Reversed flow propagation during IVR may become a sensitive clinical marker of regional ischemia.

Analysis of Variance↗

Left atrial volumes assessed by three- and two-dimensional echocardiography compared to MRI estimates.

OBJECTIVES: The aim of the present study was to establish the accuracy and reproducibility of left atrial volume measurements by three-dimensional (3D) echocardiography compared to 2D biplane and monoplane measurements. BACKGROUND: No echocardiographic technique is generally accepted as optimal for estimation of left atrial size. METHODS: Left atrial volumes of 18 unselected cardiac patients were obtained with magnetic resonance imaging (MRI) (volumes 145 +/- 58 ml). These volumes were compared with those obtained with different echocardiographic methods: a multiplane 3D method based on 90 images acquired by apical probe rotation, a simplified 3D method using only the three standard apical views, and 2D biplane and monoplane methods based on area-length, disc summation and spherical formulas. RESULTS: The echocardiographic methods significantly underestimated maximum left atrial volumes as obtained by MRI by 14-37% (p < 0.001). Accuracy, expressed as 1 SD of individual estimates around this systematic underestimation, was 25 to 27% for all methods, except for the 2D 2-chamber monoplane method (37%). Interobserver coefficient of variation was between 14 and 20% for all methods (n.s.). CONCLUSION: All echocardiographic methods significantly underestimated left atrial volumes as obtained by MRI. A minor non-significant improvement in individual echocardiographic estimates by the 3D methods was obtained at the cost of more time consumption. In unselected patients ultrasound image quality precludes significant improvement of left atrial volume measurements by the applied 3D methods.

Aged↗

Left ventricular volumes assessed by different new three-dimensional echocardiographic methods and ordinary biplane technique.

UNLABELLED: Three-dimensional (3D) echocardiography may overcome the problems with inadequate accuracy and reproducibility of 2D volume measurements of the left ventricle. AIMS: To establish the in vitro accuracy and reproducibility of two new methods for 3D echocardiographic volume determination as compared to biplane measurements. METHODS: Validation of volume measurements by a multiplane 3D method was performed on asymmetric latex phantoms (n = 8, true volumes 45-304 ml) using rotational acquisition of 90 image planes. Porcine agarose-filled asymmetrical left ventricles (n = 7, true volumes 34-280 ml) were measured by the same multiplane 3D method based on images acquired by probe rotation axis perpendicular (A) and parallel (B) to the ventricular long axis. Ventricular volumes were also obtained by a simplified 3D system using only the three standard apical views (C) and by the ordinary biplane Simpson's method (D). RESULTS: On latex phantoms systematic deviation from true volumes by multiplane 3D was less than 2%, and 95% variability of individual measurements from this mean was +/- 4.9%. For accuracy on left ventricles, systematic bias was small with all the methods (< 5%), but 95% variability of individual measurements was +/- 9.0%, 15.4%, 18.8% and 41.3% of true volumes for methods A-D respectively. Corresponding results in the same range were obtained for inter- and intraobserver variability. CONCLUSION: Individual in vitro volume estimates of left ventricles are of similar quality using apical multiplane or apical triplane 3D echocardiography. Both methods were superior to the ordinary apical biplane method, but inferior to multiplane 3D method with the probe directed perpendicular to the ventricular long axis.

Animals↗

Left ventricular mass assessed by three-dimensional echocardiography using rotational acquisition.

BACKGROUND: The reproducibility of left ventricular (LV) mass measurement by two-dimensional (2-D) echocardiography is inadequate for individual assessments. HYPOTHESIS: This study was undertaken to evaluate the potential of LV mass determination with a new three-dimensional (3-D) echocardiographic method compared with 2-D measurements. METHODS: Porcine agarose-filled left ventricles (n = 15, true mass 61-511 g) of different shapes were measured by a multiplane 3-D method based on 90 images acquired by probe rotation axis (1) perpendicular and (2) parallel to the ventricular long axis ["parasternal" (the left sternal border was not present as a reference point in this study) and apical views]. Mass was also obtained using (3) the biplane truncated ellipsoid and (4) area-length methods, as well as (5) the modified cube formula. Five hearts were not analyzed with the apical 3-D technique because of insufficient image quality. RESULTS: Systematic deviation from true mass was small with all methods (< 5.3%). Accuracy, expressed as 1 standard deviation of individual estimates around this systematic bias, was 7.7, 13.6, 8.2, 11.9, and 11.9% of true mass for the methods 1-5, respectively. Interobserver reproducibility, expressed as the coefficient of variation, was 4.7, 8.8, 8.1, 8.9, and 9.4% for the same methods. CONCLUSION: Limits for individual accuracy and reproducibility of LV mass estimates are nearly doubled using apical compared with "parasternal" 3-D echocardiography in vitro. A main advantage of "parasternal" 3-D compared with 2-D LV mass estimates is better reproducibility, but at the expense of greater time consumption. Apical 3-D technique is not superior to simpler 2-D methods based on "parasternal" short axis imaging.

Animals↗

Gas exchange and neurohumoral response to exercise: influence of the exercise protocol.

Maximal oxygen uptake varies with the exercise protocol, but the extent to which hormonal and metabolic responses to exercise are influenced by the exercise protocol has not been precisely defined. Twelve healthy subjects underwent maximal exercise testing using two incremental bicycle tests with individualized, identical work rate increments between 40 and 70 W. One protocol employed a 1-min and the other a 3-min duration per stage. Expiratory gas and venous blood were sampled at regular intervals for metabolic and hormonal analysis. Exercise duration for the 1-min and 3-min protocols was 6.0 +/- 0.1 and 14.3 +/- 0.3 min, respectively (P < 0.001). Significantly higher values were observed for peak VO2 and maximal ventilation during the 3-min protocol compared with the 1-min protocol (41.1 +/- 1.8 vs 38.3 +/- 1.6 ml.kg-1.min-1, P < 0.001; and 104.9 +/- 8.0 vs 97.2 + 5.7 l.min-1, P < 0.05, for peak VO2 and peak ventilation, respectively). However, the maximal workload achieved was higher during the 1-min versus the 3-min protocol (330 + 24 vs 280 + 21 W, P < 0.01). No differences were observed for maximal heart rate or blood pressure, whereas maximal plasma lactate was roughly twice as high during the 3-min compared with the 1-min protocol (7.5 +/- 0.8 vs 3.8 +/- 0.5 mmol.l-1, P < 0.001). Norepinephrine, epinephrine, dopamine, and growth hormone levels were generally higher throughout exercise during the 3-min compared with the 1-min protocol. When expressed as a percentage of peak VO2, however, differences in catecholamine levels were not observed. Endothelin levels did not change. We conclude that the exercise protocol profoundly influences exercise capacity as well as the metabolic and hormonal response to exercise and should be considered when using these variables to evaluate an intervention.

Adult↗

Exercise capacity of heart transplant recipients: the importance of chronotropic incompetence.

BACKGROUND: Maximal exercise capacity is limited in patients after heart transplantation. The extent to which chronotropic incompetence contributes to this intolerance has not been well defined. METHODS: This prospective cross-sectional study examined the heart rate response to exercise and its relation to exercise capacity in 159 heart transplant recipients during progressive, symptom-limited, upright exercise. All prior exercise studies of heart transplant recipients that reported peak oxygen uptake and peak heart rate were also evaluated. RESULTS: Peak oxygen uptake was closely correlated with peak heart rate (r = 0.39, p < 0.001) and maximum increase in heart rate (r = 0.49, p < 0.001) during exercise by our patients. Similar correlations were found in the published studies for peak oxygen uptake versus maximal heart rate (r = 0.54, p < 0.05) and peak oxygen uptake versus increase in heart rate (r = 0.63, p < 0.02). The current study showed that the increase in heart rate from rest to peak exercise was significantly higher and the decline in heart rate after exercise significantly faster for patients 2 or more years after transplantation than for patients less than 2 years after transplantation (46 +/- 2 versus 38 +/- 1.9 beats/min, p < 0.05); the decline in heart rate 4 minutes after exercise was 27 +/- 1.8 versus 16 +/- 1.8 beats/min, respectively ( p < 0.001). CONCLUSION: The reduction in peak oxygen consumption, particularly during the first 2 years, appears to be related in part to chronotropic incompetence. Late after transplantation the heart rate response to exercise is greater and the decline in heart rate after exercise faster, suggesting possible autonomic reinnervation in some patients. Chronotropic incompetence may be an inadequate explanation of oxygen uptake impairment seen late after transplantation, when other factors such as myocardial dysfunction and intrinsic skeletal muscle abnormalities are of increasing importance.

Analysis of Variance↗