On-line monitoring of yeast cell growth by impedance spectroscopy.

The application of impedance spectroscopy to estimate on-line cell concentration was studied. The estimation was based on the relative variation between electrical impedance measured at low (10 kHz) and high frequencies (10 MHz). Studies were carried out to characterise the influence of changes in physical and chemical parameters on the impedance measurement. Two different possibilities to perform on-line measurements were tested: a simple set-up, based on an in situ probe, gave good results but was not suitable for high agitation and aeration rates. An ex situ flow-through on-line measuring cell was used to overcome these problems, showing a better performance. The use of this set-up for the growth monitorisation of a Saccharomyces cerevisiae culture showed an efficient performance, having the correlation between estimated and measured S. cerevisiae a Pearson coefficient of 0.999.

Biomass↗

Algorithms for parametric images in MEIT systems.

In this work we show the algorithms developed to extract the Cole parameters from multi-frequency EIT. With these parameters it is possible to obtain information about various different tissues and their pathologies. The algorithms developed obtain the Cole-model parameters from the real and imaginary parts of impedance, or using only the real part, without problems of convergence. A study of the influence of noise is performed with simulations. We find a correct solution in all cases with signal to noise ratio in the data higher than 40 dB. Finally, we show parametric images of the human abdomen obtained with these algorithms.

Abdomen↗

Percutaneous electrocatheter technique for on-line detection of healed transmural myocardial infarction.

Healed myocardial infarction has been recognized by its particular tissue electrical impedance spectrum measured with intramural needle electrodes in animal models. The aim of this study was to develop a percutaneous approach for in vivo recognition of areas of healed myocardial infarction by measuring myocardial electrical impedance with an intracavitary contact electrocatheter. Electrical impedance (resistance and phase angle) of normal myocardium and of a 2-month-old anterior transmural infarction were measured in nine chloralose anesthetized pigs by applying alternating currents from 1 kHz to 1 MHZ between a bipolar intracavitary catheter and a reference electrode placed on the epicardium (group I, n = 4) or on the precordium (group II, n = 5). Resistance of the infarcted myocardium was lower than that of healthy tissue at all current frequencies (ANOVA, P < 0.001) (i.e., at 1 kHz: 15 +/- 4 omega vs 50 +/- 19 omega in group I, and 64 +/- 13 omega vs 76 +/- 13 omega in group II). Phase angle at 316 kHz best differentiated transmural infarction from normal tissue (group I: -2.5 +/- 1.9 degrees vs -14.8 +/- 4.6 degrees, P < 0.001; group II: +0.7 +/- 1.0 degrees vs -2.7 +/- 1.4 degrees, P < 0.001). This study shows that analysis of myocardial impedance spectrum using a percutaneous intracavitary contact catheter approach permits on-line recognition of areas of healed transmural myocardial infarction. This technique may be useful to optimize clinical application of energy sources (i.e., radiofrequency ablation, laser myocardial revascularization).

Analysis of Variance↗

In vivo and in situ ischemic tissue characterization using electrical impedance spectroscopy.

The investigation of processes of ischemia in different organ tissues is very important for the development of methods of protection and preservation during surgical procedures. Electrical impedance spectroscopy was used to distinguish between different tissues and their degree of ischemia. We describe mathematical methods used to adjust experimental data to Cole-Cole models for one-circle and two-circle impedance loci and a study of the main parameters for representing the behavior of ischemia in time. In vivo and in situ postmortem measurements of different tissues from pigs are shown in the 100 Hz to 1 MHz range. The Cole parameters that best characterize the ischemia are R0 and fc.

Animals↗

Biomass monitoring using impedance spectroscopy.

The biomass density in biotechnological processes is often determined by indirect and manual methods. Electrical impedance spectroscopy can provide online viable biomass density estimators. In this work, we present two linear estimators obtained with this technique. Four different microorganisms were measured. The detection threshold was approximately 1 g/L (dry weight) for bacteria and 0.5 g/L for yeast. Liposome suspensions were also used to validate the methods. The monitoring of the continuous growth of a yeast culture is also presented.

Biomass↗

Passive transmission of ischemic ST segment changes in low electrical resistance myocardial infarct scar in the pig.

OBJECTIVES: To analyze the passive electrical properties of a healed infarction and assess their role on transmission of contiguous ischemic ST segment potential changes. METHODS: We measured tissue resistivity (omega cm) at 1 kHz and the epicardial ST segment during 1 h of proximal reocclusion of the left anterior descending (LAD) coronary artery in 12 anesthetized pigs with one-month-old transmural infarction elicited by LAD ligature below the first branch. The impedance spectrum (1 to 1000 kHz) of normal and infarcted myocardium was measured in seven other pigs with similar infarctions. Electrical transmission of current pulses (30 microA) in infarcted tissue and in test solutions was also investigated. RESULTS: The infarct scar has a lower than normal resistivity (110 +/- 30 omega cm vs. 235 +/- 60 omega cm, p < 0.0001) and, unlike the normal myocardium, resistivity and phase angle of the scar did not change at increasing current frequencies, reflecting no capacitative response. LAD reocclusion induced a resistivity rise (510 +/- 135 omega cm, p < 0.01) and a ST segment elevation (0.6 +/- 0.7 to 9.5 +/- 5.1 mV, p = 0.002) in the ischemic peri-infarction zone, whereas the infarcted area showed ST segment elevation (0.5 +/- 0.5 to 3.8 +/- 2.6 mV, p = 0.03) with no resistivity changes. Potential decay of both ST segment and current pulses in the scar and in 0.9% NaCl solution was less than 1 mV/mm. Transmural deposition of connective tissue was seen in the center of the infarction. CONCLUSIONS: A one-month-old transmural infarction is a low resistance, noncapacitative medium that allows a good transmission of current pulses and of ST segment potential changes generated by contiguous peri-infarction ischemia.

Animals↗

A parallel broadband real-time system for electrical impedance tomography.

This paper deals with the design, implementation and performance of TIE-4sys, an electrical impedance tomograph. This instrument is a parallel broad-band real-time system. It measures impedance using an array of 16 electrodes and reconstructs the images using a weighted back-projection technique. The objective of this development is to enable multifrequency EIT clinical studies to be undertaken. The system is capable of acquiring 25 frames/s and makes multifrequency cardiac-gated images. The frequency range is from 10 kHz to 250 kHz and the signal to noise ratio for the real component is better than 60 dB.

Electric Impedance↗

Broadband quasi-differential multifrequency electrical impedance imaging system.

Dynamic and multifrequency imaging methods have been demonstrated both theoretically and experimentally. Multifrequency methods are able to produce images of static structures inside the measured object. Data collection systems, however, are affected by errors due to their non-ideal frequency behaviour. If the frequencies used in the measurement were close enough, the system would behave in almost the same way. In this case, however, the impedance change displayed by biological tissues is small, so the situation is similar to dynamic imaging. We call this method the quasi-differential imaging method. We have designed and built an instrument able to apply signals from 1 kHz to 1 MHz, with frequency increments of 10 Hz. Patient interface circuits and demodulators were designed to display a flat response in the full frequency range of operation. Signals are digitized with 16 bit resolution and sent to the host computer using a high-speed serial interface. This allows a maximum measurement speed of about 8 images/s. All the system parts were full characterized out of the system and the results of these measurements are given as an indication of the limits of its use as a quasi-static imaging or quasi-differential imaging data collection system.

Electric Impedance↗

A wide-band AC-coupled current source for electrical impedance tomography.

A current source suitable for application in electrical impedance tomography (EIT) is described. The first stage of the commercially available current-feedback amplifier AD844 constitutes a current-conveyor implementation and allows the construction of wide-bandwidth current sources, thus avoiding the mismatching and temperature-induced problems that arise in discrete realizations. The lack in gain accuracy of this circuit is overcome by the inclusion of its input buffer in an operational amplifier (op amp) feedback loop. Saturation problems that appear when placing a DC-blocking capacitor between the source and the electrode are solved by a DC feedback that maintains DC voltage at the output near to 0 V without reducing the output impedance of the source. Two AC-coupled current sources, in both inverting and non-inverting configurations, are described and their possible applications to EIT are listed.

Amplifiers, Electronic↗