Comparison of long-term outcomes of patients treated with nonthoracotomy and thoracotomy implantable defibrillators.

In 193 consecutive patients treated with implantable defibrillators at our institution, thoracotomy approaches were used in 87 patients and nonthoracotomy approaches in 106 patients. Long-term outcomes of the 2 groups were compared by the intention-to-treat analysis. Surgical mortality (30-day mortality) rates were 5.7% in the thoracotomy group and 0% in the nonthoracotomy group. Six of 106 patients who underwent nonthoracotomy implantation had a high defibrillation threshold and did not receive nonthoracotomy defibrillators. The duration of follow-up was 52 +/- 31 months in the thoracotomy group, and 23 +/- 15 months in nonthoracotomy group. Actuarial survival rates at 6 and 24 months were, respectively, 90% and 81% in nonthoracotomy patients and 89% and 80% in thoracotomy patients (p = NS). In patients with left ventricular ejection fraction <30%, surgical mortality was 0% by the nonthoracotomy and 10% by the thoracotomy approach. Despite the 10% difference in 30-day mortality, survival rates at 6 months were 85% in nonthoracotomy patients and 81% in thoracotomy patients. At 24 months they were 73% in nonthoracotomy patients and 74% in thoracotomy patients. Thus, this nonrandomized study suggests that while short-term survival is better in nonthoracotomy patients than thoracotomy patients, the difference in survival diminishes quickly during the first few months and disappears by 6 months. The results were similar in patients with severe ventricular dysfunction. Several important implantable-cardioverter defibrillator (ICD) trials initially utilized thoracotomy ICDs. Although questions may be raised with regard to applicability of such a trial in the era of nonthoracotomy ICDs, this study suggests that the results of such ICD trials will be largely applicable to patients treated with nonthoracotomy ICDs.

Aged↗

Comparison and frequency of ventricular arrhythmias after defibrillator implantation by thoracotomy versus nonthoracotomy approaches.

Postoperative exacerbation of ventricular arrhythmias has been reported in some patients treated with thoracotomy implantable cardioverter-defibrillators (ICDs). This phenomenon, which may be related to epicardial patch electrodes, may be less frequent after nonthoracotomy ICD implantation. In this nonrandomized study, postoperative arrhythmias in thoracotomy approaches (n = 52) were compared with those in nonthoracotomy approaches (n = 59). Preoperatively, all patients were clinically stable receiving an antiarrhythmic regimen chosen by serial drug testing. Nine of 52 patients in the thoracotomy group developed sustained ventricular tachycardia postoperatively while receiving the same antiarrhythmic regimen chosen preoperatively, and 1 patient eventually died. Two additional patients developed frequent and prolonged episodes of nonsustained ventricular tachycardia requiring changes in the antiarrhythmic regimen. In the nonthoracotomy group, only 3 of 59 patients developed sustained ventricular tachycardia and 1 developed frequent nonsustained ventricular tachycardia. Thus, only 4 of 59 patients in the nonthoracotomy group developed clinically significant ventricular arrhythmia during the postoperative period compared with 11 of 52 patients in the thoracotomy group (p < 0.05). Surgical mortality was 6% in the thoracotomy group, and 0% in the nonthoracotomy group. In the remaining clinically stable patients, a marked (sevenfold) increase in asymptomatic ventricular arrhythmias was noted in 15 of 39 patients in the thoracotomy group, and in 3 of 55 patients in the nonthoracotomy group (p < 0.05). Thus, postoperative exacerbation of ventricular arrhythmia, sometimes noted with thoracotomy approaches, is very rare with nonthoracotomy approaches.

Aged↗

Comparison of defibrillator therapy and other therapeutic modalities for sustained ventricular tachycardia or ventricular fibrillation associated with coronary artery disease.

Outcomes of 282 patients referred to the arrhythmia service at Montefiore Medical Center for sustained ventricular tachycardia (n = 214) or ventricular fibrillation (n = 68) associated with coronary artery disease were analyzed retrospectively. All patients underwent serial drug trials by electrophysiologic testing and Holter monitoring. Sixty-eight patients who did not respond to drug therapy were treated with implantable cardioverter-defibrillators (ICD group), and 214 patients were treated with other methods guided by electrophysiologic testing and Holter monitoring (non-ICD group). The non-ICD group included 49 patients who responded to drug therapy as judged by electrophysiologic testing, as well as patients who did not respond and were not treated with defibrillator therapy for various reasons. Ten patients died in the hospital (2 patients in the ICD group, 8 in the non-ICD group). Actuarial survival rates free of total cardiac death at 1, 2, and 3 years were, respectively, 94%, 87%, and 85% in the ICD group, and 82%, 78%, and 73% in the non-ICD group (p = NS). Survival rates free of total death at 1, 2, and 3 years were 90%, 82%, and 76% in the ICD group, and 82%, 76%, and 70% in the non-ICD group, respectively (p = NS). Survival rates free of total cardiac and total deaths of 49 patients treated with an effective regimen determined by electrophysiologic testing were not significantly different from those of the ICD group. This retrospective study suggests that outcomes of patients treated with ICDs may not be dramatically different from those of patients treated with other methods guided primarily by electrophysiologic testing.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Influence of left ventricular function on survival and mode of death after implantable defibrillator therapy (Cleveland Clinic Foundation and Montefiore Medical Center experience).

To determine the influence of left ventricular (LV) function on survival and mode of death in patients with an implantable cardioverter-defibrillator (ICD), sudden death, surgical mortality, total arrhythmia-related death, total cardiac death and total death were retrospectively evaluated in 377 consecutive patients. The outcomes were also compared between patients with an LV ejection fraction > or = 30% (214 patients, group 1) and < 30% (148 patients, group 2). Surgical mortality was 3.9% (1.8% in group 1, 7% in group 2). During the follow-up of 25 +/- 20 months, actuarial survival rates of all patients at 3 years were 96% for sudden deaths, 81% for total cardiac deaths and 74% for total mortality. When the 2 groups were compared, survival rates of groups 1 and 2 at 3 years, respectively, were 99 and 90% for sudden death (p < 0.05), 97 and 84% for sudden death and surgical mortality (p < 0.01), 94 and 80% for the total arrhythmia-related death (p < 0.001), 88 and 68% for total cardiac death (p < 0.0001), and 81 and 62% for total mortality (p < 0.002). In group 2, 73% of total cardiac deaths within 1 year were causally related to the arrhythmia. Thus, in patients with an ICD, sudden death rates were very low. However, total cardiac death and total death rates were relatively higher. The outcomes of patients with an ICD were strongly influenced by the degree of LV dysfunction.(ABSTRACT TRUNCATED AT 250 WORDS)

Actuarial Analysis↗

Initial experience with transvenous implantable cardioverter defibrillator lead systems: operative morbidity and mortality.

Introduction of non-thoracotomy lead systems (Medtronic, Inc.) for the implantable cardioverter defibrillator (ICD) has expanded the indications for use of this mode of therapy. Patients previously considered "too ill" to undergo a thoracotomy as well as patients who are at a high risk for developing sudden death but without previous cardiac arrest, are now considered candidates. The initial experience with the non-thoracotomy lead system at our institution was analyzed for morbidity and mortality. Thirty-four patients underwent attempted intravascular lead implantation, with 30 having initial successful implantation (88.2%). There were 23 males; average ejection fraction (EF) was 38.6%. Three patients developed pulmonary edema and low output immediately after the procedure. Three patients developed electromechanical dissociation during defibrillation threshold testing. A prolonged testing time for the non-thoracotomy lead system was noted when compared to the thoracotomy system (57.39 vs 32.30 min; P < 0.0000). There were more intraoperative morbidities with the non-thoracotomy leads than with the thoracotomy system. There were no perioperative deaths. The potential consequences of prolonged anesthesia time and extensive defibrillation threshold testing should be considered when choosing the route of ICD implant, the type of anesthesia, and the intraoperative testing protocol for each patient.

Defibrillators, Implantable↗

Long-term stability of defibrillation thresholds with intrapericardial defibrillator patches.

From March 1982 to May 1, 1992, 105 consecutive patients underwent initial implant of cardioverter defibrillators (ICD) at our institution. Twenty-nine patients (23 male and 6 female, average ejection fraction 32.24%) with ICD systems implanted via thoracotomy and either intra- or extrapericardial patches, had one or more revisions including 56 generator changes or staged implant procedures, three patch revisions, one patch lead fracture without revision, and one sensing lead revision. The time between pulse generator revisions averaged 19.5 months. Initial defibrillation threshold mean was 12.8 joules (n = 25); at first revision, 14.46 joules (n = 29), (P = NS); by fifth revision, 15.0 joules (n = 2), (P = NS). One patch was noted to be crinkled at 70 months; one patch had migrated by 39 months, and two patch leads had fractured at the costal margin by 69 and 90 months. One patient with marginal defibrillation thresholds had an additional patch placed at revision to an upgraded ICD unit. Once acceptable defibrillation threshold (DFT) is obtained, the long-term intrapericardial DFT remains stable unless a specific problem occurs. As a small, nonstatistically significant increase in DFT may occur, caution must be exercised in patients with marginal DFTs.

Amiodarone↗

Left ventricular outflow tract obstruction following repair of pneumococcal mitral annular abscess.

An unusual case of a mitral annular abscess caused by Streptococcus pneumoniae was diagnosed by transesophageal echocardiography. The patient underwent surgical resection of the abscess and developed outflow tract obstruction. This is an unusual complication of the surgical procedure. The outflow tract obstruction may have been due to anterior displacement of the mitral valve by the abscess.

Abscess↗

Electrophysiological effect of the maze procedure on canine sinoatrial node function.

The maze procedure is an operation that has had great initial success in curing atrial fibrillation. This procedure includes several right atrial incisions that may interrupt the integrity of the sinoatrial node or its arterial supply. To assess the effect of the maze procedure on sinus node function (SNF), the following studies were performed: sinus node recovery times (SNRT), corrected SNRT (CSNRT), CSNRT under autonomic blockade maximal heart rate and intrinsic heart rates. Thirty-four dogs underwent a right thoracotomy with cardiopulmonary bypass (CPB). The dogs were divided into three groups. Group 1 (n = 9), the sham group, underwent CPB without any incisions. Group 2 (n = 8) underwent CPB and one of the right atrial incisions. Group 3 (n = 18) underwent CPB and all three of the right atrial incisions. SNF was determined before and after the procedure. Groups 1 and 2 had no significant difference in measured SNF acutely after the procedure. In Group 3 the mean SNRT increased from 552 msec to 1,984 msec (P = 0.005). Sinus node dysfunction was corroborated by all studies. In the chronic studies, a trend toward recovery of SNF was observed. The maze procedure results in significant acute sinus node dysfunction. This dysfunction may resolve spontaneously over the ensuing months. Modifications of the maze procedure that avoid the sinus node or its blood supply area may reduce procedure related sinus node dysfunction.

Animals↗

Clinical evaluation of the safety of repetitive intraoperative defibrillation threshold testing.

One goal of the initial implantation procedure for a cardioverter defibrillator is determination of the configuration and patch location with the lowest defibrillation threshold (DFT). To determine the safety of multiple defibrillation tests, an analysis of the intraoperative defibrillation threshold tests (DFTT) in our patients was performed. In 84 patients, the mean number of DFT trials was 5.27; the mean number of joules received was 275.0. The maximum number of shocks in one implant procedure was 50 for a total of 4,895 joules without complications. Four patients received 30 or more DFT shocks without complication. There were two complications related directly to the DFTT: one patient with severe noninflammatory cardiomyopathy developed electromechanical dissociation and was subsequently resuscitated and survived; the second patient with severe triple vessel coronary artery disease suffered an intraoperative myocardial infarction during testing and eventually died 22 days postoperatively. All patients received an ICD unit; six patients had DFTs of greater than 20 joules. Based on our experience, we followed the clinical status (heart rate, blood pressure, ECG changes, fluid status, total anesthesia time) during the DFTT to determine the extent and duration of our testing protocol. Multiple shocks due to repositioning of the leads in a stable patient should not prohibit extensive testing as adverse consequences do not appear to be cumulative.

Electric Countershock↗

Influence of left ventricular function on outcome of patients treated with implantable defibrillators.

BACKGROUND: The outcomes of patients treated with implantable defibrillators were compared between patients with left ventricular ejection fraction greater than or equal to 30% and less than 30%. METHODS AND RESULTS: Of 68 consecutive patients treated with implantable defibrillators, 40 patients (group 1) had left ventricular ejection fraction greater than or equal to 30%, and 28 patients (group 2) had left ventricular ejection fraction less than 30%. Sudden death, surgical mortality, nonsudden arrhythmia-related death (death within 24 hours after an arrhythmic event despite initial termination of the arrhythmia by the implantable defibrillator), total arrhythmia-related death (including sudden death, surgical death, and nonsudden arrhythmia-related death), and total cardiac death were compared between the two groups. Surgical mortality was 4.4% (0% in group 1, 11% in group 2). During the follow-up of 31 +/- 27 months, actuarial survival rates free of events were 97%, 97%, and 97% in group 1 and 96%, 91%, and 82% in group 2 at 12, 24, and 36 months, respectively, for sudden death (p = NS); 97%, 97%, and 97% in group 1 and 85%, 81%, and 72% in group 2 at 12, 24, and 36 months, respectively, for sudden death and surgical mortality (p less than 0.05); 97%, 97%, and 97% in group 1 and 82%, 78%, and 70% in group 2 at 12, 24, and 36 months, respectively, for total arrhythmia-related death (p less than 0.05); and 95%, 95%, and 95% in group 1 and 82%, 69%, and 57% in group 2 at 12, 24, and 36 months, respectively, for total cardiac death (p less than 0.05). Four (57%) of seven nonsudden cardiac deaths during the initial 36-month follow-up period were causally related to arrhythmia (three surgical deaths and one arrhythmia-related nonsudden death). CONCLUSIONS: The outcome of patients treated with implantable defibrillators is strongly influenced by the degree of left ventricular dysfunction. In group 1 patients, surgical mortality, sudden death, and total cardiac death are rare. In group 2, sudden death rate may not be markedly different from that of group 1 patients. However, the risk of therapy (surgical mortality) is high. Many nonsudden cardiac deaths are causally related to arrhythmia (surgical mortality or nonsudden arrhythmia-related death). Therefore, the survival rate free of total arrhythmia-related death is significantly lower in group 2 (70% versus 97% in group 1 at 3 years). Further studies are needed to determine the roles of defibrillator therapy and other therapies in various clinical settings.

Actuarial Analysis↗

Removal of infected transvenous leads requiring cardiopulmonary bypass or inflow occlusion.

Infection, although uncommon, can be the most lethal of all potential complications after transvenous pacemaker implantation. The infection rate at our institution has been 0.56% (42 implants) during the preceding 17 years for 7435 transvenous pacemakers implanted in 4333 patients. Four of the 42 patients required use of cardiopulmonary bypass or inflow occlusion to remove the infected transvenous leads. Seven patients had their pacemakers implanted elsewhere and were transferred to our medical center for treatment. One patient died postoperatively because of persistent sepsis from a retained lead segment. All other patients survived, and none had recurrent infection. We recommend removal of all hardware if there is infection of the pacemaker system. If traction or other methods fail to remove the transvenous portion of the pacemaker system, open methods of removal, although rarely required, are safe and effective and should be used without delay.

Adolescent↗

Exacerbation of ventricular arrhythmias during the postoperative period after implantation of an automatic defibrillator.

The postoperative course of 68 consecutive patients treated with an implantable defibrillator during the period from 1982 through 1990 was studied. In 46 patients (group 1), no concomitant surgery was performed during the implantation. In 22 patients (group 2), concomitant surgery (coronary artery bypass [n = 12], valve replacement [n = 3] or arrhythmia surgery [n = 7]) was performed. All patients in group 1 were clinically stable before surgery, receiving an antiarrhythmic regimen chosen by serial drug testings. The same regimen was continued postoperatively. Eight of the 46 patients in group 1 whose condition had been stable in the hospital for 19 +/- 25 days preoperatively developed multiple episodes of sustained ventricular tachycardia 4 +/- 9 days after implantation while receiving the same antiarrhythmic regimen. Although the exacerbation was transient in some patients, six required different antiarrhythmic therapy and one eventually died. Two additional patients had frequent and prolonged episodes of nonsustained ventricular tachycardia that could trigger the defibrillator, requiring changes in the antiarrhythmic regimen. Another patient had progressive cardiac failure and died on day 5. A marked (sevenfold) increase in asymptomatic ventricular arrhythmias was noted in 42% of the remaining 35 patients. In group 2 (combined surgery), one patient developed refractory ventricular tachycardia 3 days postoperatively and died on that day. Three patients developed frequent nonsustained ventricular tachycardia postoperatively, requiring changes in the antiarrhythmic regimen. The overall surgical mortality rate was 4.4% (4.3% in group 1 and 4.5% in group 2) and was due to refractory ventricular tachycardia in two patients and cardiac failure in one.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Benefits of implantable defibrillators are overestimated by sudden death rates and better represented by the total arrhythmic death rate.

Benefits of the implantable defibrillator on survival were studied in 56 consecutive patients (concomitant coronary bypass or arrythmia surgery in 15) during an 8 year period between 1982 and 1990. During a follow-up period of 29 +/- 25 months, six patients had a sudden death and eight patients had a nonsudden cardiac death. Nonsudden cardiac deaths included three surgical deaths (death within 30 days after the surgery; two in patients without and one in a patient with concomitant cardiac surgery), one arrhythmia-related nonsudden death (death within 24 h after an arrhythmic event despite initial termination of the arrhythmia by the implantable defibrillators) and four nonarrhythmic cardiac deaths. The actuarial survival rate free of events at 1, 2 and 3 years was 96%, 96% and 92%, respectively, for sudden death, 91%, 91% and 87% for sudden death and surgical mortality and 89%, 89% and 85% for total arrhythmic death (sudden death, surgical mortality and arrhythmia-related nonsudden death). Thus, in patients treated with an implantable defibrillator, 1) the rate of sudden death is low (8% at 3 years); 2) 50% of nonsudden cardiac deaths are causally related to arrhythmia (surgical mortality or arrhythmia-related nonsudden death); 3) the total arrhythmic death rate is substantially higher than the sudden death rate; and 4) benefits of an implantable defibrillator are overestimated by reported sudden death and nonsudden cardiac death rates. The benefits may be better represented by the total arrhythmic death and nonarrhythmic cardiac death rates.

Actuarial Analysis↗

Survival of patients with the automatic implantable cardioverter defibrillator.

Between May 1982 and May 1988, 37 patients (28 males and 9 females, mean age 57.6, range 16-76 years) of approximately 600 evaluated for sustained ventricular tachycardia and/or fibrillation (VT/VF) were treated with an automatic implantable cardioverter defibrillator (AICD). Twenty-eight of the patients had coronary artery disease, 7 had nonischemic cardiomyopathy, 1 had amyloid heart disease, and 1 had rheumatic heart disease. The mean ejection fraction was 32.2 +/- 12.9% (range, 9-64%). Eleven patients have died at a mean of 16.7 months after implantation. The cumulative survival rate was 81% at 1 year, 77% at 2 years, 68% at 3 years, and 53% at 4, 5, and 6 years. Considering only sudden deaths, the survival was 97% at 1 and 2 years, 90% at 3 years, and 80% at 4, 5, and 6 years. Twenty-one of the 37 patients received spontaneous shocks. If the first shock marks the time to death in the absence of an AICD, the cumulative survival rate would have been 56% at 1 year, 42% at 2 years, 29% at 3 years, and 14% at 4, 5, and 6 years. The maximum amount of time to a first appropriate shock was 39.7 months. Thirty-nine devices have been explanted: 28 for battery depletion; 5 for infections; 3 for improper sensing; 2 for electronic failure; and 1 at the time of cardiac transplantation. The average time to failure of the 28 units removed for battery depletion was 19.8 +/- 6.9 months.(ABSTRACT TRUNCATED AT 250 WORDS)

Actuarial Analysis↗

Automatic implantable cardioverter-defibrillator: patient survival, battery longevity and shock delivery analysis.

The automatic implantable cardioverter-defibrillator (AICD) has been shown to reduce the mortality rate of patients with malignant ventricular tachyarrhythmias. This report describes experience with implantation of 36 automatic implantable cardioverter-defibrillators (AID-B and AID-BR models) in 22 persons over a 44 month patient follow-up period (mean 19.6 months). There were five deaths: two patients died suddenly 22 and 29 months, respectively, after their second implant, one died of congestive heart failure, one died of respiratory failure and one died of catheter sepsis. Although 11 (50%) of the 22 patients never received a countershock for a ventricular tachyarrhythmia and are still alive, the other 11 received one or more spontaneous countershocks. Nine patients (41%) experienced spurious shocks during the follow-up period. Assuming that the first shock for presumed ventricular tachyarrhythmia prevented death, the hypothetical cumulative survival of patients at 42 months would have been 34 +/- 14.1% in the absence of an automatic implantable cardioverter defibrillator rather than the actual survival rate of 59 +/- 16.8%. The cumulative device survival of the 36 AID-B units was 92 +/- 5.62% at 15 months but diminished to 37 +/- 14.4% by 20 months. No unit lasted longer than 22 months. There were 12 battery depletions. The number of shocks emitted did not influence unit longevity. The manufacturer's elective replacement indicator is of uncertain validity. Six units remained active 7 to 17 months after surpassing their replacement indicator. The automatic implantable cardioverter-defibrillator prolongs the life of many patients with otherwise intractable arrhythmias.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗