PubMed Health⌕ Search

Biomedical subjects

R Buchinger

Publications and source records attributed to R Buchinger.

5 recordsLinked to original sources

[Comparative experimental investigations with bioglass (L. L. Hench), Al2O3-ceramic and Al2O3-ceramic coated with a mod. Bioglass. I. Results of experiments under non-loaded conditions (author's transl)].

This report deals with comparative results obtained with unloaded intra-osseous implants of bioglass (L. L. Hench), Al2O3-ceramic and Al2O3-ceramic coated with a mod. bioglass. Al2O3-ceramic and bone form a direct bony interface without fibrous tissue interposition, this resulting in a pure mechanic fixation of the implant through frictional forces of the surface roughed ceramic. Pure bioglass (45S5) and bone form a unique persisting direct interface by means of physico-chemical or biochemical phaenomena stabilizing the implant. Interface stability seams to be higher than the fatique strenth of the glass itself. This interface is developed as a consequence of solubility of some of the glass constituents within a surface layer of up to 200 microns, running parallel with a reduction of strength of this surface glass layer. The boronoxide containing bioglass, flame-sprayed onto Al2O3-ceramic samples seams to be less soluble and therefore seams to have lesser bonding capability to bone. The stability of the interface bioglass coating-Al2O3-ceramic was low.

Aluminum↗

[Experimental investigation on non-specific foreign body sarcoma induction of Al2O3-ceramic implants (author's transl)].

This investigation presents experimental results on possible non-specific foreign body sarcoma induction by Al2O3-ceramic implants. Solid and porous discs, subcutaneously implanted in rats produce a sarcoma rate of 17.4 resp. 17.8 p.c. while roughly perforated discs initiate sarcomas at a rate of 25.4 p.c. These values were found to be lower than comparative values in the literature produced with different metals and medical grade plastics. Powdered alumina implants did not produce any sarcomas. Only this latter result can mainly be transferred into prognostic assumptions concerning the clinical application of Al2O3-ceramic. The results are discussed extensively in the lights of the existing literature, this indicating that the tested ceramic itself may not possess a significant sarcogenetic potency in humans.

Aluminum↗

Evaluation of a bioglass-coated Al2O3 total hip prosthesis in sheep.

A bioglass-coated fully dense alumina total hip was evaluated in sheep without using polymer bone "cement." After 3 months following surgery, both the acetabular cup and femoral stem component were firmly attached to bone. Histologic and radiographic analysis of the bone-implant interface showed regions of woven and even lamellar bone formation where high load transmission occurred. In regions of low loading or poor fit, a pseudosynovial fibrous lining was present.

Acetabulum↗