PubMed HealthSearch

Biomedical subjects

R C Beck

Publications and source records attributed to R C Beck.

7 recordsLinked to original sources

A comparison of internal standards for plant cytophotometry.

Plant cell nuclei were compared with chicken erythrocyte nuclei for use as internal standards for microspectrophotometry. The amount of DNA per nucleus and the coefficient of variation for measurement of individual nuclei were determined for cells from dormant embryos of Pinus taeda and Pinus coulteri, from onion root tips and from chicken erythrocytes. The chicken erythrocytes had the least variability and thus were best suited for use as a standard. Onion root tips were least suitable, with a coefficient of variation 2 1/2 times that of erythrocytes. Although onion root tips have been used as an internal standard in other studies, their mitotic activity, in contrast with the nonreplication of DNA of mature erythrocytes, is reflected in a broad distribution of nuclei with values in the 2C-4C range. Coulter pine mature embryos were at the 3C level, whether dry or hydrated, while loblolly pine embryos were in the 2C state. This confirms previous reports. The coefficient of variability for the pine embryo cells was 1 1/2 times that of erythrocytes for nonhydrated seeds and twice the erythrocyte value for hydrated seeds. The larger 2C values for pine (26 pg for P. taeda and 17 pg for P. coulteri) are closer to values expected for many plant species than the 3 pg level of the chicken erythrocytes. Dormant P. taeda embryo cells (2C) are suggested as an alternative where the experimental material has large DNA values and/or chicken erythrocytes are difficult to procure. Large sample size is recommended for the plant materials if they are to be used as internal standards in Feulgen cytophotometry.

Allium

Pacemaker diagnostic diagrams.

Dual-chamber pacemakers interact with cardiac rhythms in complex ways. The resultant surface electrocardiograms (ECGs) are often very difficult to interpret. A simple and automatic diagnostic diagram is described that graphically illustrates pacemaker-heart interactions. Pacemaker operation is explained by a continuous series of lines and symbols that interconnect any sequence of paced and sensed events in both chambers. Fixed, programmable, and adaptive pacemaker timing intervals are all shown in a simple format. The pacemaker diagnostic diagram is plotted directly below the ECG to help users interpret the paced cardiac rhythm. The pacemaker diagnostic diagram is generated by software in a pacemaker programmer from: (1) telemetered real-time event markers; (2) fixed and programmable timing parameters (lower rate, AV interval, etc.); (3) pacemaker conditional logic. If this computer analysis of the telemetered event markers is not consistent with normal pacemaker operation, a specific error-message is printed. The pacemaker diagnostic diagram should be useful for instruction, pacemaker follow-up, and troubleshooting.

Arrhythmias, Cardiac