Normal female anal sphincter: difficulties in interpretation explained.

PURPOSE: Our aims were to quantify the nature, characteristics, and frequency of variations in female anal sphincter anatomy. METHODS: Nulliparous patients from the antenatal clinic and healthy volunteers of both genders were studied. Sphincter length was determined by the position of the puborectalis sling. Defects in the external anal sphincter were defined at each level and recorded in degrees. Cylindric longitudinal images of the endoanal scans were created by a three-dimensional-representation software package. Manometry was performed by a pull-through technique. RESULTS: Fifty-seven nulliparous patients and 18 healthy volunteers were included in the study. The mean age was 39 years for males and 28.35 years for females. There was no significant difference in overall sphincter length or in the internal anal sphincter length as a percentage of overall sphincter length between genders. All nine males had a complete ring of external anal sphincter along the full sphincter length. In the external anal sphincter below the level of the puborectalis sling, a natural gap occurred in 43 nulliparous (75 percent) and all 9 female volunteers. The greater the size of the defect, the greater its extent (mean 1.33 cm for >90 degrees and 1.16 cm for <90 degrees; chi-squared P = 0.008, eight degrees of freedom). Manometry provided confirmatory evidence of the gaps seen. Anal manometry was analyzed by Mann-Whitney U test for continuous nonparametric data and t-test for comparison between genders. CONCLUSION: The female sphincter has a variable natural defect occurring along its anterior length. This makes interpretation of the isolated endoanal ultrasound difficult and explains previous overreporting of obstetric sphincter defects.

Adult↗

Outpatient hand held manometry: comparison of techniques.

OBJECTIVE: Anorectal manometry is an established important investigation in a number of disorders. The specialist ano-rectal laboratory is not always available, and a hand held manometer may be a useful tool in the outpatient setting to avoid an unnecessary visit to the anorectal physiology laboratory. Our aims were to determine whether the hand held manometer was as reliable as the standard system used in the anorectal laboratory, and to correctly compare the results from these two different techniques. PATIENTS AND METHODS: 24 patients visiting the Anorectal physiology laboratory were studies. Resting pressure, squeeze and cough pressures were recorded using the single channel hand held solid pressure transducer and with the dual channel pressure transducer MRP2 recorder. The first measurement by each method is used to illustrate the comparison of methods, the second measurement being used to study repeatability. RESULTS: The two methods correlate well for resting and squeeze pressures (Spearman coefficient with P < 0.01 for both) The level of agreement between the two methods was good for resting pressure recordings with a mean difference of 15 cm H2O. The same cannot be said for squeeze and cough pressures. Repeatability of both methods was good with mean differences on repeated recordings near zero. CONCLUSIONS: The hand held manometer is as repeatable as the laboratory but as some discrepancy occurs between the two methods they are not interchangeable. Thus the hand held manometer used alone in the outpatients Department is a useful screening and research tool.

Journal Article↗