PubMed Health⌕ Search

Biomedical subjects

R C Castells

Publications and source records attributed to R C Castells.

3 recordsLinked to original sources

Behavior of n-alkanes on poly(oxyethylene) capillary columns. Evaluation of interfacial effects.

The solvation behavior of n-alkanes on poly(oxyethylene) was studied employing capillary gas chromatography. Interfacial effects were discriminated and evaluated through the analysis of retention data from six commercial fused-silica capillary columns, having film thicknesses of 0.15-5 microm. Expressions for the mixed retention mechanism in capillary columns were deduced from assumptions of a general character. Partition coefficients were determined for the n-alkanes up to 28 carbon atoms, at temperatures ranging from 40 to 240 degrees C. In agreement with other authors, it was observed that interfacial phenomena contribute poorly to the chromatographic retention, being negligible over 140 degrees C for homologues with less than 16 carbons.

Alkanes↗

Initial evaluation of quantitative performance of chromatographic methods using replicates at multiple concentrations.

The introduction of a novel analytical method must be supported by consistent information about its quantitative potentialities; this is critical for whoever considers its utilization for an specific application. Unfortunately, literature abounds in papers proposing excellent chromatographic methods of analysis that have been subjected to comparatively poor quantitative evaluation. The methodology proposed in the present work makes use of some of the performance characteristics whose measurement is recommended in validation protocols; pertinent to this stage of method development are the detection and quantitation limits, the linear range and the repeatability. All this information can be calculated from the results of a calibration with several replicates at each analyte level. Replicates enable the calculation of reproducibility at several analyte levels and the estimation of the linear range; more important, replicates are necessary to detect changes in peak area standard deviation with analyte amount. Regression of calibration data by means of unweighted least-squares (ULSR) can only be performed in those cases in which homoscedasticity has been previously verified; heteroscedastic calibration data demand regression by means of weighted least-squares (WLSR), since ULSR results in gross overestimation of prediction limits at low analyte concentration. The proposal is used for the preliminary quantitative evaluation of a method for the determination of nine biogenic amines by means of pre-column derivatization with dabsyl chloride and separation of derivatives by RPLC. Limits of detection are calculated by a regression approach and by the classical signal-to-noise ratio method (S/N approach). No significant difference was detected for the amines limits of detection estimated by WLSR and by the S/N approach; ULSR estimated limits of detection are between 7 and 78 times larger than those obtained by the other two methods, as a consequence of the heteroscedasticity of calibration data.

Calibration↗

Gas chromatographic study of the hydrogen bonding of aliphatic alcohols to tri-n-octylphosphine oxide.

Retention volumes of 21 aliphatic alcohols were measured at five temperatures between 30 and 60 degrees C in columns packed with different percentages of squalane or with solutions of tri-n-octylphosphine oxide (TOPO) in squalane coated on previously deactivated Chromosorb W. Experimental data fit to a 1:1 alcohol-TOPO association model, with association constants ranging from 26 to 59 dm3 mol(-1) at 45 degrees C. Association constants follow the trend primary alcohols>secondary alcohols>tertiary alcohols, with minor differences between the members of each of these three groups. The association enthalpy for the 21 alcohols averages -21.8 kJ mol(-1), with a standard deviation of -1.3 kJ mol(-1).

Alcohols↗