Tubular heart valves: a new tissue prosthesis design--preclinical evaluation of the 3F aortic bioprosthesis.

BACKGROUND: It was hypothesized that native heart valves function as if they were simple tubes with sides that collapse when external pressure is applied. Because "form follows function," this hypothesis could theoretically be confirmed by implanting a simple tube into the anatomic position of any native heart valve and documenting that under the same anatomic constraints and physiologic conditions as the native valve, the tube would assume the form of that native valve. If the hypothesis were thus proved, it would follow that a tissue valve based on a tubular design would have superior flow dynamics and stress distribution and would therefore be expected to outlast currently available tissue valves. Such a tubular tissue valve, the 3F Aortic Bioprosthesis (3F Therapeutics, Inc, Lake Forest, Calif) was designed and tested in vitro against a commercially available stentless aortic bioprosthesis. METHODS: With the use of state-of-the-art testing equipment, some of which had to be developed especially to test this truly stentless bioprosthesis in vitro, transvalvular gradients, effective orifice areas, degree of transvalvular laminar flow, finite element analysis of the distribution of leaflet stress, and accelerated wear testing for long-term durability were evaluated for the new 3F Aortic Bioprosthesis in comparison with the St Jude Medical Toronto SPV aortic bioprosthesis (St Jude Medical, Inc, St Paul, Minn). RESULTS: The valve gradients were lower and the effective orifice areas were greater for the 3F Aortic Bioprosthesis at all valve sizes and under all test conditions, including cardiac outputs ranging from 2.0 to 7.0 L/min, mean perfusion pressures from 40 to 200 mm Hg, and aortic compliances of 4% and 16%. The transvalvular flow across the 3F Aortic Bioprosthesis in vitro was qualitatively smooth, with a minimum of surrounding vortices. Maximum stress occurred in the belly of the leaflets of the 3F Aortic Bioprosthesis, with minimum stress at the commissural posts. The 3F Aortic Bioprosthesis was superior to the Toronto SPV valve in accelerated wear tests. CONCLUSIONS: These in vitro studies show that a tissue aortic valve designed on the basis of the proved engineering principle that form follows function has better hemodynamics, flow dynamics, stress distribution, and durability when compared under identical in vitro conditions with an excellent commercially available tissue aortic valve.

Biomechanical Phenomena↗

Characterization of a polyepoxy compound fixed porcine heart valve bioprosthesis.

Concerns with the currently available bioprostheses are calcification, long-term durability, and suboptimal hemodynamic performance. It is well known that these concerns are all more or less related to the cross-linking reagent, glutaraldehyde or formaldehyde, used in fixing bioprostheses. To address these concerns, we undertook the development of a porcine bioprosthesis fixed with a polyepoxy compound. In the development of this polyepoxy compound valve, it was found that the porcine leaflets fixed with polyepoxy compound were softer and more pliable than those fixed with glutaraldehyde. In this study, a special microtoming technique was developed to section the biological tissue so that the fixation uniformity in distinct layers of porcine aortic wall could be characterized. The fixation index and the denaturation temperature measurements in distinct layers of aortic walls showed that the cross-linking density was uniform throughout the entire aortic wall for the polyepoxy compound fixed porcine valve. It was also noted that the fixation index of the polyepoxy compound fixed aortic wall (91.5 +/- 0.5, n = 3) was not significantly different from that of its valvular leaflet (90.6 +/- 0.8, n = 3). Similarly, the denaturation temperature of the polyepoxy compound fixed aortic wall (80.4 +/- 0.9 degrees C, n = 5) was statistically comparable to that of its valvular leaflet (79.0 +/- 0.5 degrees C, n = 5). The results of this study indicated that polyepoxy compound can adequately fix the entire porcine aortic wall as well as its valvular leaflets.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Fixation of bioprosthetic tissues with monofunctional and multifunctional polyepoxy compounds.

Collagen from a native tissue is fixed with a polyepoxy compound (PC) for use as a new biologic prosthetic material. Prior studies have shown that this biomaterial has comparable properties with collagen fixed with glutaraldehyde (GA), and thus has great promise for biomedical applications. A prior kinetic study indicated that the reaction between the functional groups of collagen and the multifunctional epoxy EX-313 is a 2.5th-order reaction. The purpose of this study was to understand the mechanism of the amino acid-PC reactions in a fixation process. Bovine arteries were fixed with a monofunctional PC (EX-131) and a multifunctional PC (EX-313) as a function of fixation time. A sequential fixation with a second fixative was used to identify the available remaining reactive sites from a prior fixation. The denaturation temperature (Td) was measured on each sample. Because the denaturation temperature is a direct indication of crosslinking of individual amino acids with the fixative, the increase in Td of a subsequent fixation may be indicative of the available remaining amino acids. The fixation index was measured on each sample to reflect the increase of fixation completion in a sequential fixation process. The fixation index and crosslink data also revealed that the reactive amino acids for EX-131 and EX-313 may not be exactly the same. The data in this study suggest that a monofunctional fixative can pre-react with the amino acids of collagen to effectively block further fixation of collagen with a second fixative. This amino acid masking may be associated with collagen branching. Collagen branching and its effect on denaturation temperature are described.

Animals↗

The closing velocity of mechanical heart valve leaflets.

The closing motion of the occluder leaflets in bileaflet type mechanical heart valves (MHV) was monitored with a laser sweeping technique. The angular displacements of the leaflets were registered with precision of 0.2 microsecond steps. Experimental measurements were made using five 29 mm Edwards-Duromedics including three original specification (EDOS) and two modified specification (EDMS), and two 29 mm St Jude Medical MHVs. The testing valve was installed in the mitral position of a physiologic pulsatile mock circulatory flow loop using water-glycerine solution as the testing fluid. Each valve was tested by: (1) direct mounting the valve on metal washers, and (2) mounting the valve with its sewing ring. Experiments were carried out at pulse rates of 70, 90, and 120 beats min-1, with the corresponding cardiac output of 5, 6, and 7.5 litres min-1, and maximum left ventricular pressure gradients (dp/dt) of 1,800, 3,000 and 5,600 mm Hg s-1, respectively. The maximum leaflet closing velocity of each of the tested valve types are presented. The difference in leaflet closing movements between the direct rigid mounting and the sewing ring mounting are discussed. The details of the laser sweeping technique are presented.

Biomechanical Phenomena↗

Neural net-bootstrap hybrid methods for prediction of complications in patients implanted with artificial heart valves.

A novel hybrid methodology for prediction of valve related complications in patients with implanted artificial heart valves is discussed. Artificial neural networks provided a mechanism for prediction of postoperative valve-related deaths based on preoperative patient information and valve parameters. Then bootstrap methodology was applied for estimating prediction errors and maximizing prediction accuracy. Data from a clinical trial with 10 years of follow-up on 789 patients implanted with Carpentier-Edwards Pericardial Bioprosthesis were used. A random subset of the data was reserved for validation of the final outcome. The remaining patients' records were repeatedly divided into two groups, using resampling strategy provided by the bootstrap methodology. One of the groups was used for training the neural net and the other one for testing the trained network and determining error rates. Patient information, such as sex, age, NYHA class and anticoagulation therapy, as well as valve parameters, such as size and the date of implant were used as the network inputs. Calculated error rates were then used for assessing the distribution of the error, further optimization of the neural network, and constructing confidence intervals for the error rates. Thus, reliable statistical estimation was obtained on the prediction accuracy. Additionally this new hybrid methodology allowed us to optimize the neural network even further, raising the accuracy of prediction to 78%.

Bioprosthesis↗

Kinetic study of collagen fixation with polyepoxy fixatives.

A new biomaterial has been developed by fixing native collagen with a polyepoxy compound (PC) fixative. In this study, bovine internal thoracic arteries were fixed with PC under various conditions to help understand the kinetics of the collagen-PC reactions and optimize the fixation process. At predetermined time intervals, small samples were cut from the arteries to determine the quantities of the remaining unreacted amino acids in the collagen. Temperature, concentration, and solution pH were among the key parameters studied. The overall fixation rate was found to be reaction-rate controlled, as the rate of fixation was relatively slow compared with the rate of diffusion of PC. As might be expected, the reaction rate was favored by a higher temperature, concentration, and solution pH. A kinetic model, with a 2.5th reaction order with respect to the reactive functional groups of collagen and a first order with respect to PC, was developed that gave a good fit to the experimental data. Based on this model, the degree of fixation, X, as a function of time, t, is given by (1 - X)-1.5 = 1 + Kt, where K is a constant related to the initial concentrations and the reaction rate constant.

Amino Acids↗

Hemodynamic evaluation of a bioprosthetic venous prosthesis.

PURPOSE: A prosthetic venous valve must be biocompatible and nonthrombogenic and function in the venous circulation. Biocompatibility and thrombogenicity of our prosthesis have been examined in prior animal experiments, and 91% of valve conduits including early prototypes are patent at 3 weeks. However, evaluation of valve function is much more difficult in animals; therefore in this study the function of excised valves was evaluated ex vivo. METHODS: Nine bovine jugular vein conduits, each with one bileaflet venous valve, were harvested and placed in a venous flow simulator. Flows and pressures were adjusted to mimic human respiratory and hydrostatic variations. Each valve and conduit was tested for variations in valve diameter and sinus expansion in response to flow. Valve opening and closing times and valve competence were measured in response to pressure changes. After testing, each specimen was glutaraldehyde fixed and assessed a second time. RESULTS: Valve orifice area increased in response to flow in both fresh and fixed tissues. Maximum valve orifice area was reduced by fixation (27.7%) at full flows (p < 0.05). Valve sinus dimensions increased in response to increased pressure until maximum expansion was achieved (33 mm Hg). This was reduced 15.3% in fixed tissue (p < 0.05). Valve opening times (at < 1 mm Hg gradient) were slightly longer in fixed compared with fresh tissue (0.43 +/- 0.09 vs 0.41 +/- 0.13 second; p < 0.05). Valve closing times were comparable in both states (0.43 +/- 0.08 vs 0.49 +/- 0.07 second). Three fresh and seven fixed specimens that were subjected to 287 mm Hg back pressure exhibited minimal reflux. CONCLUSIONS: Size and availability make the bovine jugular vein valve an ideal venous valve substitute. Glutaraldehyde fixation renders the tissue biocompatible and nonthrombogenic while preserving anatomic integrity and leaflet strength and flexibility. Mounted and stented in a sewing sleeve, this prosthesis could represent the first generally applicable clinical solution to chronic venous insufficiency and venous hypertension.

Adult↗

Prediction of valve-related complications for artificial heart valves using adaptive neural networks: a preliminary study.

A novel approach to the prediction of valve-related complications in patients with implanted artificial heart valves is discussed. Adaptive artificial neural networks were used to identify patients at high risk of valve-related events based on preoperative data. Data from a clinical trial on 789 subjects with Carpentier-Edwards pericardial bioprostheses were used. Patients' records were divided into two groups, one of which was used for training the neural network and the other for testing the trained network and determining error rates. Patient information such as age, sex, NYHA class and anticoagulation therapy, as well as valve information such as size and the date of implant, were used as the network inputs. The neural net had a single output variable indicating the risk that an individual patient would develop a valve-related complication resulting in death. The results show that a trained neural network was able to predict valve-related deaths in the specified time interval of 1981-1991 with a high degree of accuracy. The neural network was also successful in classifying patients into high and low risk categories.

Animals↗

A compliant biological vascular prosthesis.

One requirement of the mechanical parameters for an acceptable vascular prosthesis is compliance. The compliance of a vascular prosthesis is defined as the fractional change in luminal volume per unit change in applied pressure. A compliant prosthesis has been correlated to prosthesis patency and long-term efficacy in an animal study. However, there have been very few reports on how to manufacture a compliant prosthesis. It is the objective of this study to research the processing methods to manufacture a reasonably compliant vascular prosthesis. A new fixative, polyepoxy compound, was used to fix an artery. The arteries were fixed under different degrees of longitudinal retraction. By locking in the collagen micro-structure at an overly relaxed state and then crosslinking said collagen, the resulting biological prosthesis exhibited extreme compliance and pliability. A prosthesis matching its arterial origin in tensile modulus was achieved by crosslinking an artery at its 45% retraction longitudinally. This flexible prosthesis showed a volumetric compliance index of 18.4 +/- 0.9 % delta/100 mmHg and a longitudinal tensile modulus of 942 grams/cm2. Our current study indicated that a prosthesis fixed with polyepoxy compounds has shown more pliability than that with glutaraldehyde. Further animal study to correlate prostheses patency to different degrees of compliance is needed to confirm this proposed manufacturing approach.

Bioprosthesis↗

Development and evaluation of a pliable biological valved conduit. Part II: Functional and hemodynamic evaluation.

Many congenital cardiac malformations may require a valved conduit for the reconstruction of the right ventricular outflow tract. In spite of many endeavors made in the last 25 years, the clinical results of right ventricular outflow tract reconstruction with currently available valved conduits are still not satisfactory. Specific problems encountered clinically include suboptimal hemodynamic performance, conduit kinking or compression, and fibrous peeling from the luminal surface. To address these deficiencies, we undertook the development of a biological valved conduit: a bovine external jugular vein graft with a retained native valve cross-linked with a diglycidyl ether (DE). This study, using a canine model, was to evaluate the functional and hemodynamic performance of this newly developed valved conduit. Three 14 mm conduits, implanted as bypass grafts, right ventricle to pulmonary artery, were evaluated. The evaluation was conducted with a noninvasive color Doppler flow mapping system at pre-implantation, immediately post implantation, one- and three-months post implantation, and prior to retrieval (five-months post implantation). The two-dimensional tomographic inspection of the leaflet motion at various periods post implantation showed that the valvular leaflets in the DE treated conduit was quite pliable. No cardiac failure or valvular dysfunction was observed in any of the studied cases. The color Doppler flow mapping study demonstrated that the valve in the DE treated conduit was competent, with no conduit kinking or compression observed in any of the three cases. The spectral Doppler velocity study evidenced that the transvalvular pressure gradients of the DE treated conduit were minimal as compared to those of the currently available conduits. In conclusion, from the functional and hemodynamic performance points of view, this newly developed valved conduit is superior to those currently available.

Animals↗

In vitro pulsatile flow study on effective orifice area of prosthetic mechanical heart valves.

The effective orifice area (EOA) of a mechanical heart valve is an index of how well the valve design utilizes its primary orifice area (POA). In vitro measurements of EOA of aortic valves were maintained by means of pressure drop and root mean square flow rate measurements in a pulse duplicator during systole. Edwards-Duromedics, St. Jude Medical, and Carbomedics aortic valves of sizes 19 19 mm, 21 mm, 25 mm, and 27 mm were analyzed over a cardiac output range of 3 to 7 liters/min. The resultant ratios of EOA/POA were in the range of 0.6-0.8. A simplified equation suggested by the FDA was used in this study to calculate EOAs. To agree with original assumptions of the simplification, the entrance flow area (EFA) where upstream pressure is measured, must be large as compared to that of the test valves. If not, the formula can yield questionable results such as implying that the EOA can be larger than the POA (Walker P et al, 1992) [1]. This paper discusses the limitations in using such an equation. In conclusion, we suggest utilizing the parameter square root of 1-(POA/EFA)2 to evaluate the validity of the data processing, before using the equation. The parameter should be close to one, and in this study it was 0.997.

Biomechanical Phenomena↗

Cavitation threshold with respect to dP/dt: evaluation in 29 mm bileaflet, pyrolitic carbon heart valves.

A total of 15 bileaflet mechanical heart valves were studied in a pulse duplicator at the Helmholtz Institute (Aachen, Germany) under conditions approximating first, a physiological pressure curve and subsequently, a sinusoidal pressure curve. In this study Edwards-Duromedics valves of the modified specification were compared with the earlier version of the Edwards-Duromedics valve as well as with St. Jude Medical valves. Each valve was tested at a series of nine (9) conditions. At each condition, without altering the valve installation or the systemic conditions, each valve was filmed by two separate video systems: the Helmholtz Institute strobe light system and a high speed video recording system. All data, as recorded by each system, was then independently analyzed by both of the two contributing groups and subsequently compared. In this manner, it was possible to objectively verify not only the consistency of the data obtained, but to also determine the relative reliability of the methods for cavitation threshold detection.

Carbon↗

Evaluation of collagen modification and surface properties of a bovine artery via polyepoxy compound fixation.

Collagen of bovine internal thoracic artery (BITA) was treated with glutaraldehyde (GA) or polyepoxy compounds (PC). This study was to evaluate the surface properties as a result of tissue tanning reaction with PC. The fixation resulted in a significant reduction of available lysine, histidine, and other amino acid residues in PC fixed grafts as compared to fresh pre-fixed arteries. Among them, the lysine (Lys) content was reduced by about 80%, indicating that PC reactions mainly involve with Lys residues. Both PC and GA treatment led to crosslinking as evidenced by the increase in the denaturation temperature. The critical surface tension and the Fourier Transform Infrared Spectrum (FTIR) on a pre-implant and its 96 days explant were evaluated and found to be similar. The FTIR analysis of a pre-implant and the 96 day explant indicated that there was no lipid deposition.

Amino Acids↗

A preliminary study of the fixation mechanism of collagen reaction with a polyepoxy fixative.

A new biomaterial has been developed by fixing native collagens with a polyepoxy compound (PC) fixative. Prior studies have shown that this biomaterial has comparable properties as compared to collagen fixed with glutaraldehyde (GA) and thus has a great promise for use as an implantable bioprosthesis. The purpose of this study was to understand the mechanism of the amino acids-PC reactions in the fixation process. Bovine arteries were fixed with PC under various pH, concentration and temperature conditions as a function of fixation time. Individual amino acid components in the fresh and the fixed arteries were assayed using a Beckman amino acid analyzer to determine the degree of tanning. The denaturation temperature (Td) was also measured on each sample. Since the denaturation temperature is a direct indication of cross-linking of individual amino acids with the fixative, the difference in the degree of tanning for the same increase in Td may be indicative of the quantity of the masked, non-cross-linked amino acids. The fixation reaction data indicated that not all amino acids were cross-linked upon contacting the PC fixative. Masking appeared to be more substantial with a fixation at higher pH values.

Amino Acids↗

Evaluation of a polyepoxy compound fixed biological vascular prosthesis and an expanded polytetrafluoroethylene vascular graft.

Antithrombogenicity is one essential requirement for the successful use of small caliber vascular prostheses. In this study, a polyepoxy compound fixed, heparinized 4 mm diameter Baxter Denaflex vascular graft was evaluated against a 4 mm diameter Gore-Tex expanded polytetrafluoroethylene (ePTFE) vascular graft in the canine model. In addition to the thromboresistant characteristic conferred by heparinization, the crosslinking agent allowed the Denaflex graft to retain the original color of the native artery. Six centimeter long graft segments were implanted into the carotid arteries bilaterally in 5 dogs. The patency rate at 3 months for the Denaflex graft was 100% (five out of five) whereas in the control ePTFE graft, it was 40% (two out of five). The explanted Denaflex grafts exhibited softness and flexibility, and their luminal surfaces maintained a white color like that before implantation. To the contrary, the patent ePTFE grafts felt hard, and red thrombi covered large portions on their inner surfaces. Under microscopic observation, neointima formation was limited to regions near the anastomotic sites for both types of grafts. This experiment showed that the Denaflex vascular graft has an excellent antithrombogenic property and has a compliance similar to native arteries.

Animals↗

Noninvasive color Doppler inspection of small-diameter vascular grafts implanted in canine carotid and femoral arteries.

To noninvasively evaluate a small-diameter vascular graft (approx. 4 mm in diameter) developed for coronary artery bypass application, a state-of-the-art color Doppler flow mapping system was applied to inspect various grafts implanted in 5 canines. The grafts, including Denaflex, Gore-Tex ePTFE, and Bioflow, were implanted interpositionally in the carotid and femoral arteries. Inspections were conducted with a 5 MHz linear vascular transducer at 6 weeks postimplantation and 12 weeks postimplantation, immediately prior to retrieval. In the carotid artery position, all 5 Denaflex grafts were patent throughout the implantation period while 2 of the 5 Gore-Tex grafts were occluded at 6 weeks, and 1 more was occluded at 12 weeks. In the femoral artery position, all 5 Denaflex grafts were patent at 6 weeks; however 2 were occluded at 12 weeks. For the Bioflow grafts at 6 weeks, 3 were patent, and 2 were occluded. The same results were observed at 12 weeks. The color Doppler inspection results indicated a higher patency rate in the carotid artery position than in the femoral artery position. Furthermore, the volumetric flow rate and the wall shear stress measured with the pulsed Doppler in the carotid artery were greater than in the femoral artery. These findings suggest that the hemodynamic "environment" in which the graft was implanted may affect the graft patency rate. The Doppler inspection results obtained at 12 weeks, identical with those observed after retrieval, demonstrated that color Doppler flow mapping is a reliable method to noninvasively inspect blood flow through small-diameter vascular grafts.

Animals↗

Fluid dynamics of venous valve closure.

In vitro experiment was performed on a stented bovine jugular vein valve (VV, 14 mm I.D. x 2 cm long) and a stentless bovine jugular vein valve conduit (10 mm I.D. x 6 cm long) in a hydraulic flow loop with a downstream oscillatory pressure source to mimic respiratory changes. Simultaneous measurements were made on the valve opening area, conduit and sinus diameter changes using a specially designed laser optic system. Visualization of flow fields both proximal and distal to the venous valve, and the valve opening area were simultaneously recorded by using two video cameras. Laser Doppler anemometer surveys were made at three cross sections: the valve inlet, the valve exist, and 2 cm downstream of the venous valve to quantity flow reflux at valve closure. The experiment confirmed that the VV is a pressure-operated rather than a flow-driven device and that little or no reflux is needed to close the valve completely. The experiment further demonstrated that the VV sinus expands rapidly against back pressure, a critical character to consider in venous prosthesis design.

Animals↗

In vitro performance of venous valve prostheses. An experimental model study.

The performance of fresh and glutaraldehyde fixed bovine jugular vein valves (10 mm diameter) was investigated in an experimental flow loop that provides adjustable flow rates and a downstream oscillatory pressure. Three different venous valve (VV) conduit geometries (curved [C], straight [S], and tapered [T]), were tested. The flow loop consisted of two independently adjustable components, with the mean flow generated by adjusting the elevation difference between the head tank and outflow chamber. An adjustable sinusoidal pressure pulse was superimposed on the downstream of a VV to mimic the respiratory effects. Flow visualizations were made using 100 microns mica chip tracers in the laser illuminated flow fields. To assess VV performance under various flow conditions, the closure opening (CO), partial opening (PO), and leaflet fluttering (LF) were evaluated. At a given pulse pressure, the three conduits required different flow rates to reach CO mode. At 12 cm H2O pulse pressure, the fresh valve in C-conduit exhibited stable CO operation at a flow rate of 1.01 ml/sec. That in S and T conduits required 1.67 ml/sec and 2.25 ml/sec, respectively. At higher flow rates, PO and LF performances were observed in all three conduits. Different threshold values of pulse pressure were needed to reestablish the CO operation mode for the C, S, and T conduits, individually. These observations provide some insight into the role of conduit geometry and sinus configuration in the function of VV.

Animals↗