Epithelial adhesion and subperiosteal implants.
A case is presented which describes a chromium-cobalt molybdenum alloy maxillary subperiosteal implant which had been removed after two years of successful function for reasons unrelated to the oral environment. The studies performed on a specimen of adherent gingival cuff showed convincing evidence of epithelial attachment.