A randomized clinical trial on proximal contacts of posterior composites.

OBJECTIVE: The objective of this study was to investigate clinical changes in proximal contact strength inserting Class II composite resin restorations according to one of three randomly assigned protocols. MATERIALS AND METHODS: Seventy-one Class II restorations (MO/DO) were placed by two calibrated operators. Restorations were randomly assigned to one of three groups: one using a circumferential and two a sectional matrix system with separation rings. Proximal contacts were measured by one independent observer with a Tooth Pressure Meter immediately before treatment, and directly after finishing the restoration. RESULTS: Compared to the situation before treatment groups with a sectional matrix system resulted in a statistical significant stronger mean proximal contact strengths (p<0.05), whereas the use of a circumferential matrix system with hand-instrument resulted in a lower proximal contact strength (p<0.05). CONCLUSION: Class II posterior composite resin restorations placed with a combination of sectional matrices and separation rings resulted in a stronger proximal contact than when a circumferential matrix system was used.

Acrylic Resins↗

Comparison of proximal contacts of Class II resin composite restorations in vitro.

This study investigated the tightness of the proximal contact when placing posterior resin composite restorations with circumferential and sectional matrix systems in an in vitro model using a special measuring device (Tooth Pressure Meter). A manikin model was used with an artificial first molar in which an MO-preparation was ground, simulating the clinical situation of an amalgam replacement. This preparation was duplicated, resulting in 160 identically prepared teeth. These teeth were divided into 8 groups (n=20). In 2 groups, circumferential matrix bands (flat or contoured) in a Tofflemire retainer were applied. In the remaining 6 groups, 3 different separation rings were combined with 2 types of sectional matrix bands. All the cavities were restored using Clearfil Photo Bond and Clearfil AP-X. The tightness of the proximal contact was measured using the Tooth Pressure Meter. Data were statistically analyzed using SPSS 12. ANOVA was used to find differences in proximal contact tightness between the groups. Tukey tests were used to find differences between the homogeneous subgroups. The use of sectional matrices combined with separation rings resulted in tighter proximal contacts compared to when circumferential systems were used (p<0.001). The use of these devices is therefore recommended when posterior resin composite restorations are placed.

Analysis of Variance↗