PubMed Health⌕ Search

Biomedical subjects

R Casabona

Publications and source records attributed to R Casabona.

10 recordsLinked to original sources

The dacron aorta.

Total aorta replacement is a major and increasingly successful surgical procedure. The paper describes a patient whose progressive aneursymatic disease spread from the ascending segment to the bifurcation over a three-years period during which time after three separate operations, the aorta was totally replaced. The paper describes the diagnostic and surgical procedures deployed and shows the results of angiographic and CT scans. Credit for the success of the replacement is also given to the highly skilled anaesthetists and nurses involved.

Aortic Aneurysm, Thoracic↗

["Heart transplantation program" in Piedmont. Results of a 3-year activity].

Since 1990 the "Heart Transplant Program" has been instituted in the Piemonte Region. Until now the program had regular development according to the number of transplantations and the high quality of clinical results. Sixty heart transplantations has been performed with a 36 month survival close to 80%. Our data demonstrate that after heart transplantation prognosis of end-stage cardiac disease is highly improved either for life expectancy and for quality of life. Our program includes several aspects of scientific research from physiology to clinic, from biochemistry to immunology, from infectivology to pathology, from intensive care to surgery. Several very positive multi disciplinary investigations have been activated.

Adult↗

Stentless porcine and pericardial valve in aortic position.

Fifty-seven patients underwent aortic valve replacement with a stentless glutaraldehyde-fixed bioprosthesis; 27 received a porcine aortic valve and 30 had a bovine pericardial valve. Two groups of 30 patients each who had aortic valve replacement with a tilting-disc mechanical valve or a stented porcine bioprosthesis served as controls. There were no differences in sex, body surface area, valve lesion, and valve size among the four groups. Results were assessed on a Doppler-based determination of maximum velocity across the valve, aortic valve area, and degree of valve regurgitation. Velocity across the valve was significantly less with stentless pericardial valves than with stentless porcine valves, stented bioprostheses, and mechanical valves. Stentless valves had a significantly larger aortic valve area when compared with stented valves. Mild central aortic insufficiency was detected more often with stentless pericardial than with stentless porcine bioprostheses (p = 0.04). Stentless valves showed a higher incidence of complete atrioventricular block when compared with stented valves (p = 0.04). Long-term studies are now warranted to assess the durability of both types of stentless valves.

Adult↗

Reoperations on heart valve prostheses: an analysis of operative risks and late results.

To evaluate risks and complications of reoperations on heart valve prostheses, we reviewed data on 183 patients who underwent reoperation because of prosthetic valve malfunction. The incremental effect of the redo procedure on hospital mortality and morbidity was studied by comparing primary and reoperative procedures and analyzing a series of possible predisposing factors. Late survival after first and second reoperations was computed, and possible determinants of late mortality were examined. Overall operative mortality was 8.7%; emergency operation (p = 0.0001), previous thromboembolism (p = 0.05), and advanced New York Heart Association functional class (p = 0.031) were the independent determinants. In a series of 1,355 patients having primary or secondary isolated valve replacement, the redo procedure was a significant risk factor in the univariate analysis (p = 0.025) but not in the multivariate analysis except for the subset of patients having mitral valve replacement (p = 0.052). The postoperative course was quite complicated, as evidenced by the long mean stay in the intensive care unit (mean stay, 3.8 days; longer than 2 days for 26% of the survivors). Nevertheless, postoperative complications were not significantly greater after a redo procedure than after a primary operation. Actuarial survival at 7 years was 57.3% +/- 8%. A comparison with a nonhomogeneous series from our institution did not demonstrate significant differences. In the subset of 16 patients having a second reoperation, late survival was 37.8% +/- 16% at 2 years. Advanced New York Heart Association class (p = 0.0001), double prosthetic valve dysfunction (p = 0.003), and any indication other than primary tissue failure (p = 0.06) were determinants of late mortality.(ABSTRACT TRUNCATED AT 250 WORDS)

Bioprosthesis↗

Penetrating wound of the right ventricle with intracardiac retention of the foreign body.

The rare case of a penetrating cardiac wound with fortuitous outcome caused by a disintegrating rotating electric saw at the patient's home is described. The patient was successfully treated in two stages: Emergency treatment in the nearest hospital, where no extracorporeal circulation facilities were available, to stop the bleeding, followed by transport to, an cardiac surgery in university hospital, where a foreign body in the right ventricle was removed. Pathophysiology of heart wounds and their surgical treatment are discussed.

Adult↗

[Experience with lithium pacemaker in the University of Genova (Italy) (author's transl)].

The Authors report on their own experience of 77 lithium pacemaker implanted between 1974 and September 1977 in the Centre of Cardiac Surgery of the University of Genova (Italy). Only one generator has been replaced till now because of liquid infiltration. Rate variations in pacemaker marketed by Sorin were studied, considering the test-stand rate the first control and the following rate controls; the reliability of this parameter was confirmed.

Adult↗

The De Vega tricuspid annuloplasty. Perioperative mortality and long term follow-up.

One hundred and fifty-three patients undergoing De Vega tricuspid annuloplasty, with or without other associated cardiac procedures between January, 1979, and June, 1987, were evaluated. There were 136 hospital survivors. The follow-up was 98.1% complete for a mean of 3.7 years/patient. Operative mortality was 11.1%; preoperative NYHA class and length of CPB were significant risk factors of perioperative mortality. The actuarial survival of operative survivors at 9 years was 73.5 +/- 11.8%. There were 7 late cardiac deaths among a total of 12 late deaths. Eleven patients required reoperation (2.1 +/- 0.6% patient-year). In seven patients it was necessary for recurrence of tricuspid regurgitation; six of these had also a mitral prosthesis malfunction or a periprosthetic leak. Residual tricuspid regurgitation was judged as mild, moderate or severe in 29.9%, 11.9% and 4.3% of the patients respectively. De Vega tricuspid annuloplasty is the method of choice for mild and moderate tricuspid insufficiency; in selected cases, with a more severe degree of regurgitation, better results could be achieved with a different surgical approach.

Adolescent↗