PubMed Health⌕ Search

Biomedical subjects

R Cassidy

Publications and source records attributed to R Cassidy.

At least 19 recordsLinked to original sources

Silicate polymerization for the preparation of bed-retention frits in capillary electrochromatography

Bubble formation, which is associated with bed-retention frits, is a critical experimental problem in capillary electrochromatography systems. In this investigation, porous silica frits were prepared via spot-heating of a silicate solution, and the effects of several experimental parameters on their performance were studied. The optimal sodium silicate concentrations were 10.8% and 5.4% (w/v) for outlet and inlet frits, respectively. The heating times were 5-6 s for outlet frits and < 1 s for inlet frits. Under optimized conditions, outlet frits were 75 microns (+/- 12 microns) and the heat treatment did not make the capillary fragile at the frit location. Bubble formation was affected by frit length, density, and silanization of the frits with trimethylchlorosilane. Packed capillaries with optimized frits were used successfully in a commercial CE instrument over a normal working day without pressurization, at relatively high ionic strengths (10 mM), and over a wide range of acetonitrile compositions (20%-80%). Currents were also stable for > or = 3 h under very high current (27 microA) conditions. As part of this study, the efficiency and reproducibility of packed capillaries were also briefly evaluated.

Journal Article↗

Separation and determination of the macrolide antibiotics (erythromycin, spiramycin and oleandomycin) by capillary electrophoresis coupled with fast reductive voltammetric detection.

Separation and determination of erythromycin, spiramycin and oleandomycin by capillary zone electrophoresis coupled with fast reductive voltammetric detection using an Hg-film electrode was investigated in a simple aqueous phosphate buffer system. The influence of pH, concentration of phosphate, applied voltage, capillary length and dimension on the separation was examined and optimized. The entire separation of erythromycin, spiramycin, and oleandomycin was achieved in a 0.2 mol/L phosphate buffer system without organic modifiers. The electrochemical detection parameters, such as electrode material, applied waveform, scan rate, preconcentration potentials and preconcentration times, were investigated and discussed. This approach provides high separation efficiency and high sensitivity for all compounds, with detection limits (3 x peak-to-peak baseline noise) of 7.5 x 10(-8) mol/L for spiramycin, and 3 x 10(-7) mol/ L for erythromycin and oleandomycin. The calibration plot of peak areas for each separated peak vs. concentration of analyte was found to be linear over three orders of magnitude.

Anti-Bacterial Agents↗

Capillary electrophoresis of some tetracycline antibiotics coupled with reductive fast cyclic voltammetric detection.

The separation and quantitative performance parameters for tetracycline, chlortetracycline and oxytetracycline antibiotics were investigated by capillary zone electrophoresis coupled with fast cyclic voltammetric detection. Optimization of pH and complexation with a boric acid-sodium tetraborate buffer provided good resolution of all compounds. Detection by electrochemical reduction using fast on-line cyclic voltammetric detection with a Hg-film-microm electrode gave detection limits (2 x peak-to-peak baseline noise) of 7 x 10(-7) mol/l for tetracycline and chlortetracycline, and 1.5 x 10(-6) mol/l for oxytetracycline. The influence of electrode material, potential range and scan rate was examined and discussed. Optimal electrochemical detection was obtained at a Hg-film electrode with a waveform that consisted of an initial constant potential of -0.6 V for 200 ms followed by a cyclic voltammetry (CV) scan at 300 V/s from - 0.6 V to a vertex potential of 1.7 V. The analytical signal was obtained by plotting the integrated values of the CV current from each applied waveform as a function of time. The calibration plot (peak areas) for each separated peak was found to be linear over three-orders of magnitude.

Anti-Bacterial Agents↗

Determination of trimethoprim and sulphadoxine residues in porcine tissues and plasma.

Healthy gilts and market-ready hogs were administered a single intramuscular (IM) injection of Borgal, a commercial formulation of trimethoprim-sulfadoxine (TMP-SDX), once or twice daily. The objectives were to determine if a newly-developed high-performance liquid chromatographic (HPLC) method would be suitable for measuring the residual concentrations of TMP in the plasma of these live animals, and to determine if the administration of this veterinary drug would leave measurable residues in their plasma and tissues at slaughter. Plasma and tissue concentrations of SDX and TMP from these animals were determined over a period of 14 d using thin-layer chromatography/densitometry (TLCD), and the newly-developed HPLC method, respectively. The lowest detectable limit (LDL) for SDX in plasma and tissue was 20 ppb by TLCD. The HPLC method had a LDL of 5 ppb for TMP in plasma and tissue. Both methods were then used to provide baseline data on the absorption and depletion of TMP and SDX from these healthy animals. It was observed that both TMP and SDX were readily absorbed into the blood and tissues, but TMP was eliminated much faster than SDX. No TMP residues were detected in the plasma of any of the gilts at and beyond 21 h after drug administration. Also, no TMP residues were detected in the plasma of any of the market-ready hogs 24 h after drug administration at either the label dose or twice the label dose. Sulfadoxine residues at concentrations above the maximum residue limit (MRL) of 100 ppb were, however, detected in the plasma, muscle, kidney, liver, and injection sites of hogs slaughtered 1 and 3 d after a single IM administration at the label dose. Although SDX residues were still detectable in the lungs, kidney, liver and plasma of some hogs 10 d after administration of the label dose and twice the label dose, these were below the MRL. Postmortem examination revealed necrosis and inflammation at the injection sites, but no visible deposits of the injected drug.

Animals↗

Should all pregnant women be screened for hepatitis B?

To assess the sensitivity of historical risk factors for identification for hepatitis B surface antigen (HBsAg)-positive parturients, 4399 pregnant women were consecutively screened for HBsAg. Information regarding risk for hepatitis B infection was obtained from each HBsAg-positive parturient. Twenty-three HBsAg-positive subjects were identified (5.2/1000 deliveries). The HBsAg carrier rate (18/2231, or 8.1/1000 deliveries) was significantly higher in women of black, Asian, or Hispanic origin than in the remaining ethnic groups (non-Hispanic whites plus all others, 5/2168, or 2.3/1000 deliveries) (chi square, 5.95; p = 0.016). Risk factors for identification of HBsAg-positive women were present in 10 of 22 asymptomatic subjects (sensitivity, 45%; 95% confidence interval, 24% to 68%). Much of the information required to assess one of these risk factors, previous infection, involved detailed questioning and is unlikely to be obtained in the context of conventional obstetrical care. Routine maternal HBsAg screening programs may be needed if transmission of hepatitis B from mother to infant is to be prevented.

Carrier State↗

Here's looking at you.

Explore the source record for details and available documents.

Health Facility Administrators↗