PubMed Health⌕ Search

Biomedical subjects

R Cheek

Publications and source records attributed to R Cheek.

7 recordsLinked to original sources

Proliferating cell nuclear antigen and mitotic activity in rectal cancer: predictor of response to preoperative irradiation.

PURPOSE: This study examines the association between the pathologic response of rectal cancer after irradiation and its pretreatment proliferative state as assayed by proliferating cell nuclear antigen (PCNA) and mitotic activity. PATIENTS AND METHODS: Ninety patients with clinical stage T3 and T4 rectal cancer received preoperative irradiation followed by surgery. Pretreatment tumor biopsies were scored for PCNA activity (number of tumor cells staining immunohistochemically with an anti-PCNA monoclonal antibody) and the number of mitoses per 10 high-powered fields (hpf). Postirradiation surgical specimens were examined for extent of residual disease. RESULTS: The tumors of 33 of 90 patients (37%) exhibited marked pathologic downstaging (no residual tumor or cancer confined to the rectal wall) after preoperative irradiation. Two features were independently associated with the likelihood of marked pathologic regression after preoperative irradiation: lesion size and PCNA/mitotic activity. When stratified by tumor size, marked tumor regression occurred most frequently in smaller tumors with high PCNA/mitotic activity compared with larger tumors with lower PCNA/mitotic activity. Intermediate downstaging rates were seen for small or large tumors with moderate PCNA/mitotic activity. CONCLUSION: Tumor PCNA/mitotic activity predicts the likelihood of response to irradiation, which may aid in formulating treatment policies for patients with rectal cancer.

Adult↗

Detection of changes in material-specific memory following temporal lobectomy using the Wechsler Memory Scale-Revised.

To determine the utility of the Wechsler Memory Scale-Revised (WMS-R) in measuring material-specific memory changes, within-subject comparisons of the Verbal-Visual Memory Index discrepancy and discrepancy scores using short-term and delayed Logical Memory and Visual Reproduction subtests from the WMS-R were studied prior to and following temporal lobectomy among 30 patients with left temporal lobectomy, 30 with right temporal lobectomy, and 50 epileptic, non-surgical controls. The groups were matched on age, sex, handedness, age at seizure onset, duration of epilepsy, and presurgical Verbal and Performance IQ; the right temporal group had a higher mean educational level (p <.05). All surgical patients were left hemisphere dominant for speech; those who had persistent postoperative seizures were excluded from study. On retesting, left temporal lobectomy was associated with a marked change in short-term and delayed memory discrepancy scores primarily due to a drop in verbal memory. Right temporal lobectomy was not associated with a drop in visual memory, suggesting that the WMS-R appears to reflect decrements in material-specific memory following left but not right temporal lobectomy. The nonsurgical controls showed increases in both short-term and delayed memory discrepancy scores due to increases in short-term and delayed verbal memory. Relative to these controls, the absence of comparable increases in verbal memory among the right temporal patients suggests that right temporal lobectomy may be associated with risk to verbal memory.

Journal Article↗

Implementation of capillary blood glucose monitoring in a teaching hospital and determination of program requirements to maintain quality testing.

PURPOSE: To study the implementation of bedside capillary glucose monitoring using a hospital-wide quality control (QC) program. METHODS: A prospective study of QC performance in 7 outpatient and 39 inpatient treatment units was performed in a large teaching hospital over a 2-year period. Approximately 800 nurses were trained to perform bedside capillary glucose monitoring (Accu-Chek II, Boehringer-Mannheim, Indianapolis, IN). An eight-point QC program was instituted including proficiency testing, instrument maintenance, performance of daily controls, storage of reagent strips and supplies, instrument calibration, and documentation procedures. RESULTS: Comparison of laboratory and bedside test results (split-sample proficiency testing) revealed Y = 1.004X + 7.26, r = 0.95, with a mean percent difference of -4.2% (p < 0.001). Less than 7% of results fell outside +/- 20% of the laboratory results. QC scores (0 = worst to 4 = best), based on adherence to the QC program, improved from 0 on the first inspection to 3.7 +/- 0.17 by the 11th inspection. The most common QC deficiencies were failure to perform split-sample testing (41.4%) and failure to perform instrument maintenance (30.2%). Significant differences were noted in the QC performance of different types of medical services. During the 2-year study period, the total number of glucose assays performed in the clinical laboratories decreased by 22.2% concurrent with initiation of bedside testing. The number of instruments in the hospital increased from 10 to 46. CONCLUSIONS: Bedside capillary glucose assays can be widely implemented in large hospitals with an acceptable degree of accuracy. QC programs with frequent inspections are necessary to identify units that function inadequately, and a formal disciplinary policy is required to ensure compliance with the program.

Blood Glucose↗

Internal carotid artery occlusion: diagnostic inaccuracy of the ocular pneumoplethysmography.

The diagnosis of internal carotid artery (ICA) occlusion has serious management and prognostic consequences. The accuracy of noninvasive techniques in this setting remains questionable, with the result that contrast arteriography remains the diagnostic method of choice in patients in whom ICA occlusion is suspected. Ocular pneumoplethysmography-Gee (OPG-Gee) is one of the noninvasive methods that is still utilized extensively in the evaluation of carotid artery disease. In order to determine the real utility of OPG-Gee, the authors conducted a retrospective comparison of the results of OPG-Gee and arteriography in 26 patients (52 internal carotid arteries) who had undergone both examinations. [table: see text] With the angiography results as the standard of comparison, 4 incorrect diagnoses were obtained by OPG-Gee, thus yielding an overall accuracy of 92 for this method. However, duplex ultrasonography, also performed in the same 26 patients, correctly identified the 2 ICA occlusions defined by angiography and further demonstrated patency in the 48 arteries so shown by angiography. The authors conclude from this experience that OPG-Gee is less reliable than duplex ultrasonography in the diagnosis of ICA occlusion. Furthermore, despite the 92% overall accuracy of their results with OPG-Gee, the occurrence of both false-positive and false-negative results renders this examination modality suspect in the diagnosis of ICA occlusion.

Air↗

Isotype analysis of the anti-CENP-B anticentromere autoantibody: evidence for restricted clonality.

Utilizing the centromere B fusion protein (CENP-B) and specific, matched monoclonal antiisotype reagents in an enzyme-linked immunosorbent assay, we found that anti-CENP-B autoantibodies were skewed to the IgG1 isotype. The overall kappa:lambda light chain ratio was 2:1, although several individual sera showed a strong predominance of one of the light chains. Isoelectric focusing of light chain-skewed sera showed polyclonal patterns. Our findings are consistent with the anti-CENP-B autoantibody response being a chronic, antigen-driven response.

Autoantibodies↗