[Miniature assistance module for robot-assisted heart surgery].

During the robotic enhanced minimally invasive cardiac surgery the approach to and the space for handling instruments in the operating field are usually reduced, compared to the conventional surgery. Additional well knewn problems are the restricted capability available for accessories into and out of the closed chest and the limited assistance during the cardiac procedure. This paper is presenting two solutions of Miniature Modules for supporting the surgeon inside the closed chest. A self-sufficient Cargo Module is developed as a transportation and depot device. It provides an "inside equipment store" for the surgeon. With the Assist Module the surgical equipment, tissue and vessels can be positioned on a desired place in the operating field. This module provides the surgeon an "assistant" inside the closed chest.

Coronary Artery Bypass↗

Development of robotic enhanced endoscopic surgery for the treatment of coronary artery disease.

BACKGROUND: The introduction of robotic enhanced surgery demanded stepwise development of performed procedures on the basis of growing experience of the operating team. METHODS AND RESULTS: Between May 1999 and January 2001, this new wrist-enhanced instrumentation was used in 201 patients (156 men and 45 women, median age 64+/-10.5 years, left ventricular ejection fraction 68+/-12.4%). During the development of robotic enhanced CABG, the patients were divided into 3 groups. Group A (n=156) consisted of patients in whom the robotic system was used to harvesting the left or right internal mammary artery, or both, whereas the anastomoses were performed directly through a small chest incision. In group B (n=37), the harvest of the internal mammary arteries and the coronary anastomoses were performed totally endoscopically. In a third early group C, patient (n=8) were treated with robotic enhanced CABG via a median sternotomy already preoperatively planned, whereas gradual step-by-step application of robotic instrumentation and its feasibility were assessed. The survival rate was 99.4%. One patient (0.6%) died due to pneumonia on postoperative day 16. Conversion rate to median sternotomy was 5%. The left and right internal mammary artery conduits could be successfully harvested in 98% and 100%, respectively. The time of dissection of the left internal mammary artery could be significantly reduced alone by increasing experience. All patients were discharged from the hospital after a mean of 7 days. In 9 patients (4.5%), bleeding required reexploration. CONCLUSIONS: The introduction of this new surgical tool enables the development of new endoscopic procedures. Our results gained during the development of robotic enhanced CABG motivate us to establish a set standard for the totally endoscopic treatment of patients with 1-vessel coronary artery disease.

Anesthesia↗

Early experience with a quadrileaflet stentless mitral valve.

BACKGROUND: Presently no ideal prosthesis for mitral valve replacement exists. The quadrileaflet mitral valve (SJM-Quattro-MV; St. Jude Medical, Inc, St. Paul, MN) is a chordally supported stentless bioprosthesis. Due to its specific geometry it seems to be particularly suited for mitral valve replacement. METHODS: From March 1999 to October 2000, 12 patients (ages 71+/-2 years) received the SJM-Quattro-MV. Six patients suffered from valvular stenosis and 6 patients from incompetence. Preoperatively, all patients were in New York Heart Association functional class III, with left ventricular ejection fraction amounts of 54%+/-17%. RESULTS: Eleven patients received a medium size SJM-Quattro-MV and one patient received a large size SJM-Quattro-MV. Cross-clamp time was 99.8+/-4.9 minutes. Additional procedures were coronary artery bypass grafting (n = 3) and left atrial microwave ablation (n = 2). Postoperative mortality (n = 1) was procedure related. At follow-up of 11.6+/-5.4 months, all patients were well, the transvalvular pressure gradient was 5.0+/-1.4 mm Hg, and the effective orifice area 2.7+/-0.2 cm2. CONCLUSIONS: Our preliminary experiences with the SJM-Quattro-MV presented good clinical results and promoted an optimistic way of thinking about the further development of these valve prostheses.

Aged↗

Technique of closed chest coronary artery surgery on the beating heart.

OBJECTIVE: The application of an endoscopic stabilizer (Intuitive Surgical, Mountain View, CA, USA) enables closed chest off-pump coronary artery bypass via a four-point stab incision avoiding sternotomy and minithoracotomy. METHODS: Between May 1999 and January 2001 we operated upon a total of 37 patients (five female, 32 male, median age 62+/-9 years) suffering from coronary artery disease using totally endoscopic coronary artery bypass (TECAB), whereas an initial series of eight TECAB patients was operated upon using an endovascular bypass system (Heartport). The da Vinci surgical system was used in order to perform left internal mammary artery (LIMA) or right internal mammary artery (RIMA) harvesting and anastomoses on a beating heart in 29 patients (four female, 25 male, median age 64+/-9.8 years). Altogether 26 patients suffering from single-vessel coronary artery disease (SVCAD) were revascularized applying LIMA to the left anterior descending artery (LAD) and three patients with two diseased coronary vessels received bilateral internal mammary artery grafting (BIMA), respectively. RESULTS: In this series we had a 100% survival rate. Conversion rate to a median sternotomy was 3.4%. Patients were operated upon via four 1-cm chest incisions using the da Vinci robot for LIMA or BIMA harvesting and for performance of anastomoses on the beating heart. In the overall series of 56 patients intended to be treated by TECAB, 19 (33.9%) were converted to a minimally invasive direct coronary artery bypass procedure. CONCLUSION: This new robotic-enhanced surgical technique promotes an optimistic way of thinking about the further development of this procedure and its application in patients suffering from single-vessel CAD.

Aged↗

Closed chest coronary artery bypass on the beating heart.

Minimally invasive surgical procedures have become a part of routine cardiac surgery. The surgical techniques have been developed for the treatment of coronary artery disease in order to minimize surgical trauma. With the introduction of a 3-D-based totally endoscopically functioning system into minimally invasive cardiac (MIC) surgery, further reduction of skin incisions became possible and enhanced MIC techniques could be improved. Due to the 6 degrees freedom of motion allowed by wrist-enhanced instruments and a newly developed endoscopic stabilizer, totally endoscopic coronary artery bypass procedures on a beating heart became feasible. We present here our initial series of totally endoscopic "off-pump" coronary artery bypass grafting in patients suffering from coronary artery single vessel disease. In all patients, the procedure was successfully performed via four 1 cm chest incisions as closed-chest procedures.

Aged↗

[Symptomatic coronary patient with pathological coronary angiogram requiring surgery].

Bypass surgery has become a routine procedure for the treatment of coronary artery disease. Due to increase numbers of high-risk patients minimally invasive techniques were introduced in cardiac surgery with excellent clinical results. In addition molecular methods have been applied for primary and secondary treatment of coronary artery disease.

Coronary Angiography↗

Closed chest totally endoscopic coronary artery bypass surgery: fantasy or reality?

With the introduction of the da Vinci robotic surgical system (Intuitive Surgical, Mountain View, CA) into minimally invasive cardiac surgery, the outlook of performing coronary artery bypass operations "closed chest" became a reality. Between May 1999 and July 2000 this wrist-enhanced instrumentation was used in 143 patients (107 men, 36 women, median age 63 10.3 y). Thirteen patients suffering from coronary artery disease (CAD) were treated as totally endoscopic coronary artery bypass (TECAB), 79 patients underwent a minimally invasive direct coronary artery bypass procedure, and 35 patients were treated using the robotic-enhanced Dresden Technique. Preoperative survival was 100%. All patients in the TECAB group were operated upon via a three- or four-point stab incision using the da Vinci robot for internal mammary artery takedown and for performance of anastomoses. These new robotic-enhanced surgical techniques promote an optimistic way of thinking about the further development of these procedures and its application in patients suffering from CAD.

Aged↗

Wrist-enhanced instrumentation: moving toward totally endoscopic coronary artery bypass grafting.

BACKGROUND: With the introduction of the da Vinci robotic surgical system (Intuitive Surgical, Mountain View, CA) into minimally invasive cardiac operations the outlook for performing coronary artery bypass operations "closed chest" became a reality. METHODS: Between May 1999 and December 1999 this new wrist-enhanced instrumentation was used in 61 patients. Six patients suffering from single-vessel coronary artery disease and one female patient with double-vessel disease underwent totally endoscopic coronary artery bypass. Thirty-seven patients with single-vessel disease underwent a minimally invasive direct coronary artery bypass procedure. Seventeen patients with double-vessel disease were treated using the robotic-enhanced Dresden technique. RESULTS: Perioperative survival was 100%. In all patients the internal mammary arteries were safely harvested endoscopically and had excellent quality. In both totally endoscopic coronary artery bypass groups all patients were operated on through three stab incisions. CONCLUSIONS: Our preliminary experience with this new surgical technique using robotic-enhanced minimally invasive methods for coronary artery disease promotes optimism regarding further development of these procedures and application in patients with coronary artery disease.

Coronary Artery Bypass↗

Robotic-enhanced arterial revascularization for multivessel coronary artery disease.

BACKGROUND: A tendency to reduce operative trauma is determining the evolution of cardiac surgical techniques lately. The introduction of robotic-enhanced endoscopic systems enables surgeons to perform arterial revascularization for multivessel disease without sternotomy. METHODS: From May 1999,17 (4 women, 13 men; median age 63+/-7.4 years) patients with multivessel coronary artery disease were treated surgically using arterial revascularization by means of bilateral internal mammary arteries. Both arteries were harvested endoscopically using the da Vinci system (Intuitive Surgical, Mountain View, CA). These vessels were anastomosed using the "Dresden technique." RESULTS: Survival was 100%. Mean duration of the operation was 255+/-40.4 minutes. Bilateral internal mammary artery harvesting took 88.5+/-15.9 minutes; cross-clamp time was 36+/-8.7 minutes. An average of 2.06 anastomoses were performed per operation. Postoperatively, patients remained in the intensive care unit for 21+/-13 hours. One patient (5.8%) needed reexploration due to bleeding. CONCLUSIONS: The robotic surgical system introduces a new treatment of coronary artery disease to surgical practice, and enables arterial revascularization with distinctly reduced surgical trauma.

Anastomosis, Surgical↗

Closed chest bilateral mammary artery grafting in double-vessel coronary artery disease.

A clinical case of a closed chest double-vessel total endoscopic coronary artery bypass procedure was performed using a wrist-enhanced, three-dimensional-based robotic system. A patient suffering from lesions of the left coronary artery system was effectively treated surgically without median sternotomy or minithoracotomy. This encourages optimism for introducing closed chest endoscopic bypass operations into the surgical routine for patients suffering from double-vessel coronary artery disease.

Coronary Artery Bypass↗

Robotically enhanced "Dresden technique" with bilateral internal mammary artery grafting.

BACKGROUND: A tendency to reduce the operative trauma seems to be the prominent sign of development in cardiac surgery. The combination of the previously introduced minimally invasive "Dresden Technique" with the robotically enhanced endoscopic system enables further progress in coronary artery surgery. METHODS: From May 1999, 25 patients (19 male, 6 female, mean age 63 +/- 8.0 years) suffering from multivessel coronary artery disease (CAD) were treated surgically using arterial revascularization through the bilateral internal mammary arteries (BIMA). Both mammaries were harvested endoscopically using the da Vinci robotic system. Further, the "Dresden Technique" was applied for anastomosis of these vessels with the coronaries. RESULTS: All patients survived the surgery. Mean duration of surgery amounted (244 +/- 82.1 min). BIMA dissection took (87 +/- 18.1 min). An average of 2.2 anastomoses were performed per patient. Postoperatively, the patients remained on ICU for 19 +/- 18 hrs. One patient needed reexploration for bleeding (4%). CONCLUSIONS: The addition of robotically enhanced endoscopic mammary artery harvesting method to the "Dresden Technique" for coronary artery surgery enables the introduction of a new treatment method for CAD into surgical practice, helping to perform an arterial revascularization with a distinctly reduced surgical trauma.

Aged↗

Robotic coronary artery surgery--the evolution of a new minimally invasive approach in coronary artery surgery.

BACKGROUND: With the introduction of a wrist-enhanced robotic surgical system into minimally invasive cardiac surgery, the outlook of performing closed chest coronary artery bypass operations became a reality. METHODS: Since May, 1999, this new wrist-enhanced instrumentation has been used in 109 (79 male, 30 female, median age 63 +/- 9.9 years) patients. Seven suffering from single vessel coronary artery disease (SVD) and double vessel disease (DVD) were treated as totally endoscopic coronary artery bypass (TECAB). 60 with SVD underwent a wrist-enhanced, minimally invasive direct coronary artery bypass procedure. 25 with DVD were treated using the robotically enhanced Dresden Technique coronary artery bypass. RESULTS: Survival was 100%. In all patients the IMAs were safely harvested totally endoscopically. In the TECAB group, all patients were operated via a three-point stab incision. Data were observed during and after the operation. CONCLUSIONS: Our preliminary experiences with this new surgical technique for the robotically enhanced, minimally invasive treatment of coronary artery disease promote an optimistic way of thinking about the further development of these procedures.

Aged↗

Robotic-enhanced Dresden technique for minimally invasive bilateral internal mammary artery grafting.

BACKGROUND: The introduction of robotic-enhanced endoscopic instrumentation systems allows the surgeon to perform arterial revascularization for multivessel coronary artery disease without sternotomy. METHODS: From April 1999, 27 patients (6 female, 21 male, median age 63 +/- 8.2 years) suffering from multivessel coronary artery disease were treated surgically using arterial revascularization by means of bilateral internal mammary artery (BIMA) grafting. Both arteries were harvested totally endoscopically using the da Vinci robotic surgical system (Intuitive Surgical, Mountain View, CA). These vessels were anastomosed using the "Dresden Technique" via a left minithoracotomy in the second intercostal space. RESULTS: All patients survived the operation. The mean duration of surgery was 240 +/- 79.4 minutes. Bilateral internal mammary artery harvesting time was 88.5 +/- 15.9 minutes, and cross-clamp time was 38 +/- 10.9 minutes. An average of 2.07 anastomoses were performed per operation. Postoperatively, the patients remained in ICU for 20 +/- 2.4 hours. One patient needed reexploration due to bleeding. CONCLUSIONS: Bilateral internal mammary artery harvesting can be achieved safely with the use of wrist-enhanced instrumentation. The robotic surgical system introduces into surgical practice a new type of treatment of coronary artery disease, helping to perform arterial revascularization with a distinctly reduced surgical trauma.

Aged↗

The Dresden approach for complete multivessel revascularization.

BACKGROUND: In a prospective clinical trial, a group of patients receiving less invasive surgical procedure, including minithoracotomy in combination with cardiopulmonary bypass (group 1), was compared to a group of patients receiving conventional bypass surgery (group 2) for the treatment of coronary artery disease. METHODS: Group 1 included 85 patients (71 men, 14 women, aged 39 to 82 years, median 61.1 +/- 9.0 years); group 2 included 53 patients (38 men, 15 women, aged 51 to 79 years, median 62.0 +/- 6.1 years). RESULTS: There were no perioperative deaths in the whole series of patients. Time of operation was 256 +/- 43 minutes in group 1 and 150.0 +/- 53.6 minutes in group 2. Hospitalization was 6.0 +/- 1.4 days and intensive care unit stay 1 day for both groups. Back pain assessment on postoperative day 3 showed less pain in group 1. Three-month follow-up revealed ischemia in stress electrocardiogram in 2 patients (2.5%) in group 1 and in 2 patients (4.1%) in group 2. Coronary angiograms confirmed the stress-electrocardiogram findings. CONCLUSIONS: Surgical results are equal for both techniques. Even though time of operation is longer in patients receiving less invasive procedures, intensive care unit stay and hospital stays are the same length. Early postoperative back pain is less in group 1 and combined with faster convalescence.

Adult↗

The application of the Octopus stabilizing system for the treatment of high risk patients with coronary artery disease.

OBJECTIVES: If coronary disease is the target of a minimally invasive procedure, median sternotomy or cardiopulmonary bypass or both can be avoided. Similar to the development in other fields of surgery, minimally invasive surgical techniques are gaining increased acceptance in the field of cardiothoracic surgery. Our experience with an off pump coronary artery bypass (OPCAB) technique in a special patients group with serious risk factors for the application of cardiopulmonary bypass has been analyzed. METHODS: Between March 1996 and January 1999, 88 patients (64 male, 24 female) with impaired left ventricular function, or other high risk factors jeopardizing the use of cardiopulmonary bypass, such as impaired renal or lung function or heavily calcified aorta, received a beating heart procedure using the Medtronic Octopus stabilizing system. RESULTS: All patients survived the actual operation, however, two multimorbide patients died of pneumonia on postoperative day 31 and postoperative day 35. CONCLUSIONS: Patients with single-vessel to multivessel disease and serious risk factors for cardiopulmonary bypass can be safely treated by OPCAB surgery. At our institution this technique presents the procedure of choice in this particular patients group.

Aged↗

Coronary artery bypass grafting via median sternotomy or lateral minithoracotomy.

OBJECTIVES: In order to evaluate the benefit provided through less invasive surgical techniques for the treatment of multivessel coronary artery disease, a prospective clinical trial was started. METHODS: Group 1 included 53 patients (38 males, 15 females, age 51-79 years, mean 62.8 +/- 6.1 years) receiving conventional bypass surgery, group 2 included 69 patients (59 male, 10 female, age 43-82 years, mean 61.9 +/- 8.6 years) receiving less invasive surgical procedure including minithoracotomy in combination with cardiopulmonary bypass. RESULTS: No perioperative death occurred in the whole series of patients. Time of operation was 267 +/- 61 min in group 2 and 162.9 +/- 53.6 min in group 1. Intensive Care Unit stay was 1 day for both groups and Hospitalization 6.9 +/- 6.0 for group 1 and 7.5 +/- 2.6 days for group 2. Perioperative bleeding was less in group 2 (P > 0.01). Back and chest pain assessment on postoperative day 3 showed less pain in group 2 (P < 0.05). Three-month follow-up revealed ischemia in stress electrocardiogram in two patients (3.8%) in group 1 and in 2 patients (2.9%) in group 2. Coronary angiograms confirmed the stress ECG findings. There was one (1.4%) redo operation in group 2 and two (3.8%) in group 1. CONCLUSIONS: Both techniques are equal efficient. Even though time of operation is longer in patients receiving less invasive procedure, intensive care unit stay and hospitalization is exactly as long. Patients receiving minimally invasive surgery bleed less and have less pain early postoperatively.

Adult↗