PubMed Health⌕ Search

Biomedical subjects

R Circaud

Publications and source records attributed to R Circaud.

2 recordsLinked to original sources

Evaluation of human IgG subclass assays on Beckman array.

Automated immunonephelometric assays were developed to measure human IgG subclasses in serum, on the Beckman Array Protein System (APSR), with sheep antihuman IgG subclass antisera. The interassay imprecision was judged to be satisfactory in each case (CV: IgG1: 2.3%; IgG2: 2.9%; IgG3: 4.0% and IgG4 5.4%). The standard curves were found to be linear in the ranges 1.5-30.0 g/L for IgG1, 1.5-15.0 g/L for IgG2, 0.1-1.0 g/L for IgG3 and 0.1-1.0 g/L for IgG4. The lower limit for quantification of the immunephelometric assays was 0.5 g/L for IgG1, 0.04 g/L for IgG2, 0.06 g/L for IgG3 and 0.03 g/L for IgG4. We found no antigen excess to at least 60.0 g/L for IgG1 and IgG2, 3.5 g/L for IgG3 and 2.0 g/L for IgG4. Nephelometric results correlated with those of radial immunodiffusion (r = 0.96 for IgG1, r = 0.93 for IgG2, r = 0.90 for IgG3 and r = 0.96 for IgG4). The reaction monitored by the Beckman Array Protein System is easy to perform, rapid and precise. The performance makes the immunonephelometric method suitable for the determination of IgG subclass concentrations in routine analysis.

Adolescent↗

Rate nephelometric assay of serum lipoprotein(a).

This nephelometric assay of serum lipoprotein(a) [Lp(a)] is characterized by the use of a specific antibody to generate a high rate of light-scatter formation and the elimination of nonspecific reactions from serum samples by diluting samples in phosphate-buffered saline containing polymer enhancer polyethylene glycol (PEG), 40 g/L, and detergent before the assay. We reacted 100 microL of sixfold-diluted serum in 500 microL of buffer containing PEG with 42 microL of pure polyclonal rabbit antiserum (Dakopatts) directed against human Lp(a) and monitored the reaction by rate nephelometry with the Array Protein System nephelometer (Beckman). The standard curve for the reaction was linear in the Lp(a) range 10-1280 mg/L; antigen excess occurred between 1300 and 1400 mg/L. Calibration was performed with serial dilutions of a standard serum. Precision studies showed within-run and between-run CVs of < 2.1% and 6.9%, respectively. The nephelometric results (y) for 100 serum samples were highly correlated with those obtained by radial immunodiffusion (x) calibrated with the same materials: y = 1.07 (+/- 0.03) x - 16.2 (+/- 8.1) mg/L (r = 0.974, P < 0.001). Storing serum for 3 weeks at 4 degrees C or 3 months at -80 degrees C did not affect the results.

Humans↗