PubMed Health⌕ Search

Biomedical subjects

R Clackdoyle

Publications and source records attributed to R Clackdoyle.

7 recordsLinked to original sources

Normalizing projection images: a study of image normalizing procedures for single particle three-dimensional electron microscopy.

In the process of three-dimensional reconstruction of single particle biological macromolecules several hundreds, or thousands, of projection images are taken from tens or hundreds of independently digitized micrographs. These different micrographs show differences in the background grey level and particle contrast and, therefore, have to be normalized by scaling their pixel values before entering the reconstruction process. In this work several normalization procedures are studied using a statistical comparison framework. We finally show that the use of the different normalization methods affects the reconstruction quality, providing guidance on the choice of normalization procedures.

Algorithms↗

Fast fully 3-D image reconstruction in PET using planograms.

We present a method of performing fast and accurate three-dimensional (3-D) backprojection using only Fourier transform operations for line-integral data acquired by planar detector arrays in positron emission tomography. This approach is a 3-D extension of the two-dimensional (2-D) linogram technique of Edholm. By using a special choice of parameters to index a line of response (LOR) for a pair of planar detectors, rather than the conventional parameters used to index a LOR for a circular tomograph, all the LORs passing through a point in the field of view (FOV) lie on a 2-D plane in the four-dimensional (4-D) data space. Thus, backprojection of all the LORs passing through a point in the FOV corresponds to integration of a 2-D plane through the 4-D "planogram." The key step is that the integration along a set of parallel 2-D planes through the planogram, that is, backprojection of a plane of points, can be replaced by a 2-D section through the origin of the 4-D Fourier transform of the data. Backprojection can be performed as a sequence of Fourier transform operations, for faster implementation. In addition, we derive the central-section theorem for planogram format data, and also derive a reconstruction filter for both backprojection-filtering and filtered-backprojection reconstruction algorithms. With software-based Fourier transform calculations we provide preliminary comparisons of planogram backprojection to standard 3-D backprojection and demonstrate a reduction in computation time by a factor of approximately 15.

Algorithms↗

Exact inversion of the exponential x-ray transform for rotating slant-hole (RSH) SPECT.

The RSH SPECT scanner provides parallel-beam attenuated projections for a fully 3D acquisition geometry. The geometry can be represented by circles on the unit sphere of projection directions, one circle for each position of the detector head. Unlike most other fully 3D geometries this one is particularly challenging because there are no 2D subsets in the data. When no attenuation is present, it is well known that an unmeasured projection can be synthesized if it lies inside one of the measured circles. The main result of this work is that under some assumptions on the attenuation distribution, attenuated projections within a circle can be synthesized from available attenuated projections. One consequence is that RSH SPECT projections can be rebinned into a conventional SPECT geometry for which analytic attenuation correction techniques are available.

Algorithms↗

Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography.

This paper is about calibration of cone-beam (CB) scanners for both x-ray computed tomography and single-photon emission computed tomography. Scanner calibration refers here to the estimation of a set of parameters which fully describe the geometry of data acquisition. Such parameters are needed for the tomographic reconstruction step. The discussion is limited to the usual case where the cone vertex and planar detector move along a circular path relative to the object. It is also assumed that the detector does not have spatial distortions. We propose a new method which requires a small set of measurements of a simple calibration object consisting of two spherical objects, that can be considered as 'point' objects. This object traces two ellipses on the detector and from the parametric description of these ellipses, the calibration geometry can be determined analytically using explicit formulae. The method is robust and easy to implement. However, it is not fully general as it is assumed that the detector is parallel to the rotation axis of the scanner. Implementation details are given for an experimental x-ray CB scanner.

Calibration↗

Attenuation correction in SPECT using consistency conditions for the exponential ray transform.

Using data consistency conditions for the exponential ray transform, a method is derived to correct SPECT data for attenuation effects. No transmission measurements are required, and no operator-defined contours are needed. Furthermore, any 3D parallel-ray geometry can be considered for SPECT data acquisition, even unconventional geometries which do not lead to a set of 2D parallel-beam sinograms. The method is presented for both the 2D parallel-beam geometry and a particular 3D case, called the rotating slant hole geometry. Full details of the algorithms are given. Implementation has been carried out and results are presented in 2D and in 3D using simulated data.

Algorithms↗

Single-slice rebinning method for helical cone-beam CT.

In this paper, we present reconstruction results from helical cone-beam CT data, obtained using a simple and fast algorithm, which we call the CB-SSRB algorithm. This algorithm combines the single-slice rebinning method of PET imaging with the weighting schemes of spiral CT algorithms. The reconstruction is approximate but can be performed using 2D multislice fan-beam filtered backprojection. The quality of the results is surprisingly good, and far exceeds what one might expect, even when the pitch of the helix is large. In particular, with this algorithm comparable quality is obtained using helical cone-beam data with a normalized pitch of 10 to that obtained using standard spiral CT reconstruction with a normalized pitch of 2.

Algorithms↗

Blind estimation of compartmental model parameters.

Computation of physiologically relevant kinetic parameters from dynamic PET or SPECT imaging requires knowledge of the blood input function. This work is concerned with developing methods to accurately estimate these kinetic parameters blindly; that is, without use of a directly measured blood input function. Instead, only measurements of the output functions--the tissue time-activity curves--are used. The blind estimation method employed here minimizes a set of cross-relation equations, from which the blood term has been factored out, to determine compartmental model parameters. The method was tested with simulated data appropriate for dynamic SPECT cardiac perfusion imaging with 99mTc-teboroxime and for dynamic PET cerebral blood flow imaging with 15O water. The simulations did not model the tomographic process. Noise levels typical of the respective modalities were employed. From three to eight different regions were simulated, each with different time-activity curves. The time-activity curve (24 or 70 time points) for each region was simulated with a compartment model. The simulation used a biexponential blood input function and washin rates between 0.2 and 1.3 min(-1) and washout rates between 0.2 and 1.0 min(-1). The system of equations was solved numerically and included constraints to bound the range of possible solutions. From the cardiac simulations, washin was determined to within a scale factor of the true washin parameters with less than 6% bias and 12% variability. 99mTc-teboroxime washout results had less than 5% bias, but variability ranged from 14% to 43%. The cerebral blood flow washin parameters were determined with less than 5% bias and 4% variability. The washout parameters were determined with less than 4% bias, but had 15-30% variability. Since washin is often the parameter of most use in clinical studies, the blind estimation approach may eliminate the current necessity of measuring the input function when performing certain dynamic studies.

Brain↗