Transseptal catheterization update 1992.

Resurgence of the transseptal procedure in the last decade has occurred coincident with the advent of therapeutic catheterizations and in particular mitral balloon vavuloplasty. As larger numbers of these procedures have been performed, experience shows that the position of intended septal puncture varies for each anticipated procedure and need not lie at the fossa ovalis, which is frequently displaced or inaccessible. Recognizing the dynamic alterations in septal and atrial anatomy that accompany the various combinations of valvular heart disease, the experienced interventionalist will use precatheterization echo and radiological techniques to enable precise and localized transseptal puncture. Using these techniques in 597 patients for valvular heart disease, we have had no deaths and a morbidity of 1.8% with the transseptal puncture.

Cardiac Catheterization↗

Balloon expandable stents to treat central venous stenoses in hemodialysis patients.

Vascular access failure in hemodialysis patients remains a significant problem. The use of thrombolytic agents and balloon angioplasty instead of or in conjunction with surgical revision, has been helpful in increasing the life span of vascular access in these patients. The application of newer endovascular therapies, such as vascular stents, may further improve the salvage rate of hemodialysis access sites. These stents may be particularly valuable in treating stenoses in large central veins. We present 2 cases in which a balloon-expandable Palmaz stent was used to treat a central venous stenosis causing signs of vascular access failure.

Aged↗

Flow support catheter for prolonged maintenance of coronary blood flow.

A newly designed flow support catheter with a supporting wire mesh cage which can be expanded into a tubular configuration and then readily reduced was evaluated in mongrel dogs. Regional myocardial blood flow (RMBF) was measured using the radioactive microsphere technique in the area of both balloon-denuded instrumented and control non-instrumented coronary arteries following placement of either a fixed-wire or a higher profile rapid exchange flow support catheter. At 5, 20, and 180 min following delivery and expansion of either device, RMBF was not significantly different in left ventricular subepicardium and subendocardium perfused by the instrumented vs. the control coronary arteries. Angiography demonstrated widely patent instrumented arteries in 15/18 dogs; in no dog was side branch occlusion observed. Significant cage thrombus deposition was seen angiographically in 3 animals causing temporary total coronary occlusion in 1. Following reduction and removal of the flow support catheter, vessel patency was present in all dogs. The flow support catheter is an effective endovascular stenting device capable of providing structural arterial support, while simultaneously maintaining distal coronary blood flow. It is envisioned that the primary application of this catheter will be to enable primary salvage of vessels acutely injured during coronary angioplasty, by "tacking up" intimal flaps for an extended period. It may also provide a bridge to emergency surgical revascularization.

Angioplasty, Balloon, Coronary↗

Intracerebral haematoma mimicking intracranial neoplasm at computed tomography.

The diagnosis of a typical acute intracerebral haematoma is comparatively specific with computed tomography. Three cases are presented to illustrate computed tomographic similarities between intracerebral haematomas and intracranial neoplasms. In the appropriate clinical setting, an incorrect diagnosis may be reached unless these similarities are borne in mind.

Acute Disease↗