"Pacecare"--a computerized database for pacemaker follow-up.

A computerized database for pacemaker follow-up has been designed to run on IBM compatible hardware and to accept pulse generator and lead models of all manufacturers. Stored data includes patient, physician and implant details, indications for pacing, underlying rhythm, complications and management, program settings, and follow-up measurements. Typing is minimized by the use of "pop-up" lists and prepared pulse generator template displays. At each follow-up visit a patient's file is retrieved by surname or number, a visit record created, and measurements documented. As the template of the previous visit is used, recording of the clinic visit takes less than 1 minute. Changes in pacing rates (base or magnet), pulse widths, lead thresholds, lead impedance, and battery cell impedance can be displayed graphically for immediate recognition of end-of-life parameters or suspected malfunction. The program will print patient, implantation and clinic visit summary reports, clinic appointment lists, letters to patients, and annual reports. Two Melbourne hospitals have now entered over 3,600 patients into the database. Valuable information has been obtained regarding implantation details and trends with pulse generator and lead usage. Pacecare is a sophisticated, yet user friendly, computerized database for pacemaker follow-up. Recording of clinic visits is fast and changes in testing parameters can be recognized immediately.

Computer Systems

Drug-eluting collar--a new approach to reducing threshold.

This study evaluated the clinical performance of leads with a drug-eluting (less than 0.5 mg of dexamethasone sodium phosphate) collar (DEC) placed adjacent to a 4-mm2 Pt/Ir coated electrode (Telectronics model 030-368). Ten trailing tined ventricular silicone DEC leads and ten control leads (model 030-359) were implanted transvenously in patients of comparable age, sex, and indication for pacing. Early threshold rise, chronic thresholds (Vario), and lead impedances were monitored by pacer telemetry. The DEC lead had substantially lower thresholds in the first few weeks (P less than 0.0005) as well as chronically (P less than 0.025). The study has shown that a drug dose of less than 0.5 mg, released from a drug-eluting collar (DEC), is effective in reducing thresholds.

Aged