PubMed HealthSearch

Biomedical subjects

R Cramb

Publications and source records attributed to R Cramb.

13 recordsLinked to original sources

Approaches to the management of hypercholesterolaemia.

Patients with hypercholesterolaemia need to be carefully evaluated for underlying secondary or genetic causes. All such subjects require dietary advice. Those with total cholesterol levels persistently in excess of 6.5 mmol/l despite diet, and in the presence of multiple cardiac risk factors may need drug therapy. Drug therapy is likely to be life-long and the potential benefits need to be carefully assessed against the long-term safety of the agents employed.

Bezafibrate

Whole blood electrolyte assay using ChemPro 500. A comparison of assay performance with standard laboratory instruments.

The ChemPro 500 'near-the-patient' analyser, with ChemPro 'Ion Profile' sensor cards, was evaluated for the assay of pH, Ca2+, K+ and Na+ in whole blood samples from patients in the intensive care unit or during surgery for heart or major blood vessel disease, or for liver transplantation. Imprecisions estimated from replicate whole blood measurements were much greater for all four ions than even the least stringent of the generally accepted analytical goals, and much greater than those estimated using quality assurance materials. Comparisons of assayed values with those obtained using standard laboratory instruments showed significant constant and proportional biases. The performance of the ChemPro 500 with the Ion Profile cards gave us no confidence in recommending their use to anaesthetists and intensivists.

Biosensing Techniques

Improving the quality of plasma cholesterol measurements in primary care.

During the last 2 years an external quality assessment (EQA) scheme has been developed for plasma cholesterol measurements made in primary care. The scheme, which is supported by the UK Department of Health and by the instrument manufacturers, now has over 300 participants, most of whom use the Boehringer Reflotron. Operators are mostly nurses, with little or no laboratory experience. To avoid matrix effects, fresh plasma specimens collected from normal volunteers and those attending a hospital lipid clinic are used. Three specimens, mostly with cholesterol concentrations in the range 5-9 mmol/L, are distributed every 2 months. The mean plasma cholesterol results show good agreement with those from 'reference' laboratories, and efforts are now being made to link these laboratories with the CDC-based reference system. The scheme uses a predominantly graphical presentation of results, with a greater element of interpretation by the organisers than is usually provided for laboratory-based participants. The distribution of results shows a higher proportion of outliers than in the UK national EQA scheme for laboratory cholesterol measurements. At present about 10% of participants in primary care obtain results which could be clinically misleading, and new approaches are needed in dealing with these 'poor performers'. This scheme could serve as a model for other assays in primary care. It illustrates the importance of training, quality assurance and education, and the need for laboratory staff to become more involved in this growing and important area of laboratory medicine.

Chemistry, Clinical

Quality of plasma cholesterol measurements in primary care.

Three surveys were made of the quality of plasma cholesterol measurements performed with a commercial desktop analyser (BCL Reflotron) in primary care. Each survey included three specimens, and results were received from 37, 61, and 69 participants. Although many participants obtained satisfactory results, 8.6% of the results differed by 1.0 mmol/l or more from the target values, and the overall between instrument dispersion of results was 1.3 times that between hospital laboratories. It was found that common sources of error were poor technique and the use of outdated reagent strips. Users of such instruments outside the laboratory need help and advice with training, and guidelines for this are provided. The main recommendations are that users should establish contact with a local clinical chemistry laboratory for training and support and should participate in external quality assessment schemes.

Cholesterol

Intraoperative prochlorperazine for prevention of post-operative nausea and vomiting.

The effectiveness of 10 mg IV prochlorperazine in preventing postoperative nausea and vomiting was compared with placebo when given perioperatively to 100 patients in a prospective double-blind randomized trial. The occurrence of nausea and vomiting was assessed in the recovery room prior to and after narcotic administration for pain relief. No statistically significant difference in the frequency of postoperative nausea and vomiting was found between the treatment and control groups.

Adult

The cardiovascular and oncotic effects of albumin infusion in premature infants.

We determined the oncotic and cardiovascular effects of a standardised infusion of human albumin (1.2 g/kg over 2 h as a 20% solution) in 12 premature infants on 18 occasions when hypovolaemia was suspected on clinical grounds. Blood volume increased by a median value of 15.5%, and fell to preinfusion values by 3 h post infusion in all but four cases. Albumin concentration and colloid osmotic pressure rose during infusion and remained raised even when blood volume had fallen to preinfusion levels. Blood pressure rose in 3 cases only and heart rate fell by greater than 5 beats/min in 6 cases. Indices of long- and short-term heart rate variability were unchanged, but blood pressure variability fell in the second hour of infusion (P = 0.03), an effect which was independent of changes in lung inflation. No changes in blood gases or oxygenation occurred during infusion and no evidence of pulmonary oedema was found. There were wide variations in oncotic and cardiovascular responses to the standardised infusion both between and within subjects. When human albumin is infused in this manner some protection against respiration-induced variability in blood pressure can result, but the circulatory response may prove difficult to predict in the individual.

Blood Pressure

Comparison of potassium ISFETs with the Radiometer KNA1 and the Corning 902 ion selective electrode analysers for whole blood potassium ion estimation.

Evaluation of the performance of potassium ion sensitive field effect transistors (K+ ISFETs), developed by Thorn EMI in a form suitable for mass production and for incorporation in 'near the patient' analysers, showed only very small constant and proportional biases against the Radiometer KNA1 and the Corning 902 for whole blood potassium ion estimation. Between batch imprecision tests with whole blood showed the K+ ISFET was comparable in performance to the Corning 902 but inferior to the Radiometer KNA1. The evaluation demonstrated that ISFET manufacturing technology has now reached a stage of development at which ISFETs should be considered seriously for use in clinical chemical analysers.

Calibration

Partial purification of two lithocholic acid-binding proteins from rat liver 100 000g supernatants.

1. The partial purification of two lithocholic acid-binding proteins from liver 100 000g supernatants is described. 2. Gel-filtration, (NH4)2SO4 fractionation, Ca3(PO4)2 fractionation and ion-exchange chromatography were used. 3. Both proteins exhibited glutathione S-transferase activity; one may be the non-specific anion-binding protein ligandin. 4. Glutathione S-transferase activity of one of the binding proteins was inhibited by lithocholic acid.

Animals