PubMed HealthSearch

Biomedical subjects

R Curbelo

Publications and source records attributed to R Curbelo.

3 recordsLinked to original sources

Cytomat-R: a computer-controlled multiple laser source multiparameter flow cytophotometer system.

A multiple illumination wavelength multiparameter flow cytophotometer system, using laser sources and controlled by a small, general-purpose digital computer, has been produced for use in the development of new flow cytometric techniques. Three different laser wave-lengths can be used simultaneously to illuminate different regions of the flow chamber; as many as five measurements of light scattering at various angles, extinction, and fluorescence at one or more wavelengths can be made at each illuminated station. Cells in suspension may be examined at rates of 1000 cells/sec, with seven correlated optical measurements being recorded for each cell. A library of programs for data manipulation and statistical analysis make it possible to use the system to develop and implement cell characterization, counting and classification procedures for basic and clinical research applications.

Blood Cells

A generalized machine for automated flow cytology system design.

A general-purpose multiparameter flow cytophotometry system has been developed for use in the desgin of flow cytophotometers to perform specific tasks in automated cytology. Five separate measurement stations spaced along the axis of a capillary tube can be used to make up to eight optical measurements of individual cells flowing through the capillary. The system uses a broad-band arc source and can measure light scattered at various angles, light absorption by cell constituents and/or dyes and fluorescence of cell constituents and/or fluorochromes, excited directly and/or by energy transfer from neighboring molecules. High numerical aperture optics are used to maximize light-gathering capacity and minimize the effects of cell orientation and eccentricity of position in the fluid stream on measurements. A hard-wired preprocessor is used to detect the presence of cells and adjust sampling timing for changes in cell velocity; the electronic system also controls the gain of the detector photomultiplier tubes to compensate for background variations. Data acquistion and analysis are controled by a small general-purpose digital computer. The system has been used to develop a method and apparatus for blood cell counting and classification.

Autoanalysis

Combined blood cell counting and classification with fluorochrome stains and flow instrumentation.

A multiparameter flow cytophotometer was used to count and classify fixed human blood cells fluorochromed with a mixture of ethidium bromide (EB), brilliant sulfaflavine and a blue fluorescent stilbene disulfonic acid derivative (LN). The system measures light scattered by the cells and absorption at 420 nm for all cells. In addition, nuclear EB fluorescence (540 leads to 610 nm) and cytoplasmic fluorescence from LN (366 leads to 470 nm), brilliant sulfaflavine (420 leads to 520 nm) and EB exicted by energy transfer from LN (366 leads to 610 nm) are measured for all nucleated cells. This information is sufficient to perform red and white blood cell counts and to classify leukocytes as lymphocytes, monocytes, basophils, eosinophils or neutrophils. Light scattering and/or nuclear and cytoplasmic fluorescence values may be further analyzed to obtain the ratio of immature to mature neutrophils. Counts produced by the system are in reasonable agreement with those obtained by electronic cells counting and examination of Wright's-stained blood smears; some discrepancies appear to be due to systematic errors in the manual counting method.

Autoanalysis