R D Bloebaum

Publications and source records attributed to R D Bloebaum.

At least 19 recordsLinked to original sources

Age-related hypermineralization in the female proximal human femur.

Hip fracture incidence increases exponentially with age in virtually every human population that has been studied. In spite of this, relatively few studies have examined age-related changes in the metaphyseal cortex of the proximal femur. The present study investigates cortical aging changes in the female proximal femur, with particular reference to regions of hypermineralization. Thirty-three femora from Caucasian females were obtained at autopsy and analyzed using backscattered electron imaging. Variations in hypermineralized tissue area, cortical bone area, and porosity were quantified with standard stereological methods. Cortical width was quantified with digital calipers. Gender differences were examined by statistical comparison with previously published results. Hypermineralized tissue volume was significantly (P < 0.001) greater in elderly individuals. Hypermineralized tissue preferentially appeared near ligamentous or tendinous insertion sites, suggesting the hypermineralized tissue may be a calcified fibrocartilage. Cortical width significantly (P < 0.001) decreased with age and porosity significantly (P < 0.001) increased with age, however the changes were site-specific. The femoral neck and intertrochanteric cortices had a smaller change in cortical width and porosity with age than the diaphysis, but the femoral neck and intertrochanteric cortices had a larger increase in hypermineralized tissue. Comparison with previous data suggests that cortical aging in the proximal femur is similar between males and females and is unlikely to explain the higher incidence of fracture in females. However, the data strongly indicates that age-related changes in the femoral diaphysis cannot be directly extrapolated to either the femoral neck or intertrochanteric cortices.

Adolescent

Loading conditions and cortical bone construction of an artiodactyl calcaneus.

Customary nonuniform distributions of physiological bone strains are thought to evoke heterogeneous material adaptation in diaphyseal cortices of some limb bones. Recent studies of artiodactyl calcanei have suggested that the regional prevalence of specific mechanical strain features such as mode and magnitude correlate with specific variations in cortical bone ultrastructure, microstructure and mineralization. These data are also consistent with predictions of current algorithms of mechanically induced bone adaptation. However, detailed characterization of the customary functional strain environment of these bones is needed to understand better the mechanisms of these adaptations. An in vitro loading method and rosette strain gauges were used to record principal strains, maximum shear strains and principal strain angles at multiple locations on ten calcanei of adult male mule deer (Odocoileus hemionus hemionus). Each hind limb was fixed in an apparatus to mimic the mid-support phase of the gait and loaded via the Achilles tendon over a broad range of functional loads (0 to 2943 N). Strains were recorded on the craniolateral, craniomedial, caudal, medial and lateral cortices at mid-diaphysis. Loading variations included the progressive elimination of the ligament and tendon along the caudal calcaneus. The results showed that the cranial cortex experiences longitudinal compressive strains that are nearly equal to the principal minimum strains and that the caudal cortex receives longitudinal tensile strains that are nearly equal to the principal maximum strains. With a 981 N load, the mean principal compressive strain on the cranial cortex was -636+/-344 micro(&egr;) (mean +/- s.d., N=9) and the mean principal tensile strain on the caudal cortex was 1112+/-68 micro;(&egr;)x (N=9). In contrast to the cranial and caudal cortices, principal strains in the medial and lateral cortices displayed relatively large deviations from the longitudinal axis (medial, 24 degrees cranial; lateral, 27 degrees caudal). Although shear strains predominated at all gauge sites, variations in maximum shear strains showed no apparent regional pattern or consistent regional predominance. The plantar ligament and tendon of the superficial digital flexor muscle were shown to have important load-sharing functions. These results demonstrate that the functionally loaded artiodactyl calcaneus generally behaves like a cantilevered beam with longitudinal compression and tension strains predominating in opposing cranial and caudal cortices, respectively. Differences in osteon remodeling rates, osteon morphology and mineral content reported previously between the cranial and caudal cortices correlate, in part, with the magnitudes of the principal compressive and tensile strains, respectively. However, material differences that distinguish the medial and lateral cortices from the cranial and caudal cortices could not be primarily attributed to locally increased shear strains as previously suggested. Variations in osteon and/or collagen fiber orientation may correlate more strongly with principal strain direction.

Animals

Comparison of human, primate, and canine femora: implications for biomaterials testing in total hip replacement.

The canine model remains an animal of choice for determining the efficacy and safety of various materials and designs used in human total hip replacement (THR). The primate also is used in orthopedic-related research for studying limb anatomy, gait, and age-related bone loss. In order to better understand the appropriateness of these animal models for human THR, external morphologies of thirty-three adult Caucasian human, sixteen adult chimpanzee, and forty-two adult greyhound femora were compared using osteometric methods. Measured parameters included anteversion angle, cervico-diaphyseal angle, femoral head offset in the frontal plane, and anterior bow profiles along the femoral diaphysis. Although some of the measured parameters were approximately similar between species (e.g., mean cervico-diaphyseal angle of humans and chimpanzees), the majority demonstrated morphologic differences that may be biomechanically significant for interpreting stress transfer across the hip (e.g., mean anteversion angle and mean normalized femoral head offset between species). Additionally, age-related changes in proximal femoral morphology and gait pattern, as well as species-related differences in local muscle and inertial forces, may result in notably different loading conditions across the hip joint of each species. Therefore, discretion must be exercised when evaluating canine or primate THR materials and designs for potential use in the human hip.

Adolescent

Dissolution of particulate hydroxyapatite in a macrophage organelle model.

It is controversial as to whether debris from hydroxyapatite (HA)-coated implants jeopardizes the long-term success of total joint replacements. It has been hypothesized that liberated HA particles are engulfed by macrophages and through normal cellular digestion prevent osteolysis and third-body wear. HA particulates, however, have been observed at the interface and on polyethylene articulating surfaces. There is limited data demonstrating the ability of HA to dissolve at the acidity levels associated with macrophage organelle digestion. The objective of this study was to determine if particulate HA could dissolve at the pH levels found in macrophage organelles. Characterized HA particles were placed into buffered solutions corresponding to phagosomal organelle pH levels: cytoplasmic (pH 7), phagosomal (pH 6), and lysosomal (pH 5). Flasks were under continuous agitation in a shaker chamber at 37 degrees C. Calcium and phosphate ions were measured beyond the maximum life span of an activated macrophage. The data showed that calcium ions rose within the first 24 h and then remained constant throughout the experiment for all pH groups. Phosphate ion concentration showed a similar pattern at the lysosomal pH but remained undetected at the other organelle pH levels. The saturation point was highest at the lysosomal pH level and lowest at the cytoplasmic pH level. The results of this experiment leave the potential for HA particles to dissolve following macrophage digestion. However, caution must be exercised when interpreting the macrophage organelle digestion hypothesis; the size of the HA particle, the length of time required to completely dissolve the particle, and potential cellular toxicity all are factors that have yet to be determined before this hypothesis can be validated.

Calcium

Technique for identification of submicron metal particulate from implants in histological specimens.

Metal implants are being used with increasing frequency for the treatment of many diseases in the field of orthopedics, cardiology, cardiovascular surgery, and otolaryngology. Unfortunately, metals can be a source of submicron particles, which may have adverse effects on tissues. This article describes a technique that uses backscattered electron imaging and energy dispersive X-ray microanalysis, which have the capacity to perform both quantitative and qualitative analysis. The particles can be characterized by size, shape, amount, and composition. Although this technique can be used near the implant interface, it is particularly helpful in tissues a great distance from the implant site with a low concentration of metal debris. In addition, the sensitivity and specificity of this technique can be adjusted to the investigator's needs.

Electron Probe Microanalysis

Errors in quantitative backscattered electron analysis of bone standardized by energy-dispersive x-ray spectrometry.

Backscattered electron (BSE) imaging has proven to be a useful method for analyzing the mineral distribution in microscopic regions of bone. However, an accepted method of standardization has not been developed, limiting the utility of BSE imaging for truly quantitative analysis. Previous work has suggested that BSE images can be standardized by energy-dispersive x-ray spectrometry (EDX). Unfortunately, EDX-standardized BSE images tend to underestimate the mineral content of bone when compared with traditional ash measurements. The goal of this study is to investigate the nature of the deficit between EDX-standardized BSE images and ash measurements. A series of analytical standards, ashed bone specimens, and unembedded bone specimens were investigated to determine the source of the deficit previously reported. The primary source of error was found to be inaccurate ZAF corrections to account for the organic phase of the bone matrix. Conductive coatings, methylmethacrylate embedding media, and minor elemental constituents in bone mineral introduced negligible errors. It is suggested that the errors would remain constant and an empirical correction could be used to account for the deficit. However, extensive preliminary testing of the analysis equipment is essential.

Animals

Porous-coated metal-backed patellar components in total knee replacement. A postmortem retrieval analysis.

The use of porous-coated metal-backed patellar components to achieve consistent fixation by bone ingrowth and to provide relief of pain warrants serious scrutiny. We conducted a quantitative postmortem investigation of eleven consecutively retrieved components with use of high-resolution contact radiographs, electron microscopy, and histological analysis. The implants had been in situ for a mean (and standard deviation) of 45+/-36 months (range, one to eighty-four months). Analysis of the high-resolution contact radiographs revealed that a mean of 86+/-12 per cent (range, 61 to 100 per cent) of the porous coating was in contact with the host bone. Backscattered electron imaging showed that the mean volume fraction of bone ingrowth was 13+/-9 per cent (range, 0 to 30 per cent). No significant difference was detected, with the numbers available, between the volume fraction of the bone ingrowth measured in the porous coating and that of the host cancellous bone in the patellae.

Aged

Biomechanical implications of mineral content and microstructural variations in cortical bone of horse, elk, and sheep calcanei.

BACKGROUND: Artiodactyl and perissodactyl calcanei have been recently introduced as models for examining bone for mechanically mediated adaptation. We have reported substantial regional variations in cortical bone microstructure and mineral content within the same cross-section of mule deer calcanei. In part, these variations may be adaptations accommodating the customary presence of predominantly tension, compression, and shear strain modes in mutually exclusive cortical locations. Calcanei from skeletally mature horses, elk, and sheep were examined in order to corroborate these previous findings. METHODS: From each species, one calcaneus was obtained from each of 13 animals. Each bone was cut transversely near mid-shaft into two segments and examined for mineral (ash) content. From each species, an additional segment obtained from each of 7 of the original 13 bones was examined for microstructure using 50x backscattered electron images. Regions examined included the compression (cranial), tension (caudal), and medial and lateral (shear) cortices. Periosteal (P), middle (M), and endosteal (E) regions were also examined separately within the compression and tension cortices. Quantified microstructural parameters included: (1) secondary osteon population density (OPD), (2) fractional area of secondary bone (FASB), (3) porosity, (4) population density of new remodeling events (NRE = resorption spaces and newly forming secondary osteons), and (5) secondary osteon diameter and minimum-to-maximum chord ratio. RESULTS: Results in each species showed variations that are considered to be mechanically important and are similar to those reported in mule deer calcanei. Mineral content data suggest that remodeling activity in the compression, medial, and lateral cortices was occurring at a slower rate than remodeling in the tension cortex. In comparison to the tension cortices, the compression cortices have approximately 6.0% higher mineral content (P < 0.007) and 35% higher OPD (P < 0.01). Additionally, the compression cortices have more nearly perfectly round osteons and lower FASB, porosity, NRE, and osteon diameter (P < 0.05; except for FASB in horse where P = 0.087 and NRE in sheep where P = 0.520). However, patterns of microstructural variations between intracortical regions (P, M, E) are inconsistent when compared to data reported in mule deer calcanei. Microstructural characteristics between the medial and lateral cortices were similar although some significant differences were identified. In general, the microstructure of the medial and lateral cortices differ from the neighboring compression and tension cortices. CONCLUSIONS: Differences in mineral content and microstructure between opposing compression and tension cortices of these three species resemble differences previously reported in mule deer calcanei. The majority of the microstructural variations can be explained in the context of strain-magnitude-based rules of Frost's Mechanostat Theory of mechanically induced bone adaptation. These variations may also be strongly influenced by the strain mode predominating in each cortical location. The hypothesis that intracortical material adaptations are correlated with progressive transcortical strain magnitude variations is not supported by the inconsistent transcortical variations in material organization. These interpretations do not preclude the possibility that other specific strain features may contribute to a complex adaptive signal.

Animals

Postmortem analysis of consecutively retrieved asymmetric porous-coated tibial components.

The objective of this investigation was to conduct a postmortem analysis of 8 porous-coated asymmetric tibial components to measure the extent of radiolucencies and bone ingrowth. With the use of radiographic, electron microscope, and histologic analysis techniques, a quantitative postmortem study of 8 consecutively retrieved porous-coated tibial components was conducted. Time in situ averaged 47+/-36 months. The components were secured with 4 pegs and 2 screws. Autograft bone chips were applied to the resected tibia during implantation. Contact radiographs of an average of 8 3-mm sections from each implant revealed that 73%+/-17% of the porous coating had no apparent radiolucencies present between the host bone and porous coating for the series. Backscattered electron imaging showed that the bone ingrowth averaged 6%+/-2%. Histologic analysis was unable to demonstrate any adverse cellular response. The analysis suggested that this asymmetric implant design is stable and biocompatible and has potential for long-term clinical durability.

Aged

Reproducibility of techniques using Archimedes' principle in measuring cancellous bone volume.

Researchers have been interested in developing techniques to accurately and reproducibly measure the volume fraction of cancellous bone. Historically bone researchers have used Archimedes' principle with water to measure the volume fraction of cancellous bone. Preliminary results in our lab suggested that the calibrated water technique did not provide reproducible results. Because of this difficulty, it was decided to compare the conventional water method to a water with surfactant and a helium method using a micropycnometer. The water/surfactant and the helium methods were attempts to improve the fluid penetration into the small voids present in the cancellous bone structure. In order to compare the reproducibility of the new methods with the conventional water method, 16 cancellous bone specimens were obtained from femoral condyles of human and greyhound dog femora. The volume fraction measurements on each specimen were repeated three times with all three techniques. The results showed that the helium displacement method was more than an order of magnitudes more reproducible than the two other water methods (p < 0.05). Statistical analysis also showed that the conventional water method produced the lowest reproducibility (p < 0.05). The data from this study indicate that the helium displacement technique is a very useful, rapid and reproducible tool for quantitatively characterizing anisotropic porous tissue structures such as cancellous bone.

Animals

Determining mineral content variations in bone using backscattered electron imaging.

The mechanical properties of bones are greatly influenced by the ratio of organic constituents to mineral. Determination of bone mineral content on a macroscopic scale is straightforward, but microscopic variations, which can yield new insights into remodelling activities, mechanical strength, and integrity, are profoundly more difficult to measure. Measurement of microscopic mineral content variations in bone material has traditionally been performed using microradiography. Backscattered electron (BSE) imaging is a technique with significantly better resolution than microradiography with demonstrated consistency, and it does not suffer from projection-effect errors. We report results demonstrating the applicability of quantitative BSE imaging as a tool for measuring microscopic mineral content variations in bones representing a broad range of mineralization. Bones from ten species were analyzed with Fourier-transformed infrared spectroscopy, X-ray diffraction, energy dispersive X-ray spectrometry, ash measurements, and BSE imaging. BSE image intensity (graylevel) had a very strong positive correlation to mineral (ash) content. Compositional and crystallographic variations among bones had negligible influence on backscattered electron graylevels. The present study confirms the use of BSE imaging as a tool to measure the microscopic mineral variability in a broad range of mineralized tissues.

Animals

Analysis of particles in acetabular components from patients with osteolysis.

Acetabular polyethylene components were quantitatively analyzed for the presence of third body particles from 38 consecutively retrieved components. Backscattered electron imaging and correlated energy dispersive x-ray analysis were used for the assessments. Retrievals were divided into 4 groups based on methods of fixation and metal alloy types: 8 hydroxyapatite coated, 6 cobalt chrome porous coated, 17 titanium porous coated, and 7 cemented implants were evaluated. The backscattered electron imaging data showed that the components from the hydroxyapatite coated implants had larger particles than did the components from the cemented group. The hydroxyapatite group had 51 +/- 52 particles per mm2. The cobalt chrome alloy group had 10 +/- 9 particles per mm2, and the titanium alloy group had 9 +/- 16 particles per mm2. The cemented group had 5 +/- 4 particles per mm2. The difference between the cement group and the hydroxyapatite group was statistically significant. The elemental analysis showed that 70% of the particles in the hydroxyapatite group had calcium and phosphorus elements. Third body particles likely contribute to particulate generation. The results suggest that the hydroxyapatite coated components have the potential for producing greater amounts of particulate debris. Continued analysis of retrieved components for the presence of the third body particles is required.

Acetabulum

Lymphoreticular dissemination of metal particles after primary joint replacements.

Twenty-three patients with a history of primary joint replacement followed by lymph node dissection procedure were studied. These specimens included pelvic, gastric, paraaortic, inguinal, retroduodenal, and axillary node chains. The lymph node specimens were sectioned, processed for scanning electron microscopic study, and viewed with backscattered electron imaging to identify metal particles. On detection of a metal particle, energy dispersive x-ray microanalysis was conducted to determine its elemental composition. Seven of 23 patients had metal alloy particles within the lymph node specimens. Metal particles were identified in the pelvic and axillary node chains. In each case, the metal alloy identified corresponded with the implanted type of alloy. The shortest interval between joint implantation and dissemination of metal to a lymph node chain was 6 months. These data suggest the need for continued followup to determine long term effects, if any, of this distribution of metal particles through the lymphatic system.

Aged

Postmortem analysis of bone growth into porous-coated acetabular components.

Microradiography, backscattered electron microscopy, and histological analysis were used to conduct a quantitative postmortem study of seven consecutively retrieved anatomical porous replacement acetabular components that had been inserted during total hip arthroplasties. Screws had been used for the initial fixation of six components. The microradiographic analysis of all seven components showed that an average (and standard deviation) of 84 +/- 9 per cent (range, 72 to 93 per cent) of the porous coating was in direct apposition to the periprosthetic bone. The backscattered electron images demonstrated that an average of 12 +/- 6 per cent (range, 4 to 21 per cent) of the space available in the porous coating was occupied by ingrown bone. The amount of bone ingrowth was not significantly different among the three zones delineated by DeLee and Charnley. Uniformity of bone growth into the porous coating suggests that the preferential loading that occurs in the superior region did not differentially affect the bone ingrowth. The present study showed that consistent bone growth into anatomical porous replacement acetabular components can be achieved.

Acetabulum

Progression of human bone ingrowth into porous-coated implants. Rate of bone ingrowth in humans.

We report the measured progression of human cancellous bone ingrowth into load-bearing porous-coated titanium implants over 5 time periods (0, 3, 6, 9, and 12 months). There was a statistically significant progression of bone ingrowth into the implants over a 9-month period, but the 9- and 12-month data were not different. Investigators are advised to analyze time "0" implants in order to distinguish mechanical impaction of bone from the biological process of bone ingrowth.

Aged

Evidence of structural and material adaptation to specific strain features in cortical bone.

BACKGROUND: Functionally induced strains provide epigenetic signaling for bone modeling and remodeling activities. Strain gauge documentation of the equine third metacarpal reveals a neutral axis passing through the craniolateral cortex, resulting in a narrow band of cortex loaded predominantly in tension, with the remainder of the cortex experiencing a wide range of compression strain magnitudes that are maximal in the caudomedial cortex. This predictable strain pattern provides a model for examining the hypothesis that strain mode, magnitude, and strain energy density are potential correlates of compact bone structural and material organization. METHODS: Structural and material variables were quantified in nine equine (standard breeds) third metacarpals for comparison with the in vivo strain milieu that was evaluated in thoroughbred horses. The variables quantified included secondary osteon population density (OPD), fractional area of secondary bone (FASB), fractional area of porous spaces, collagen fiber orientation, mineral content (% ash), and cortical thickness. Each bone was sectioned transversely at 50% of length, with subsequent quantification of eight radial sectors and three intracortical regions (periosteal, middle, endosteal). Linear regression analysis compared these variables to magnitudes of corresponding regional in vivo longitudinal strain, shear strain, and strain energy density values reported in the literature. RESULTS: The craniolateral ("tension") cortex of this bone is distinguished by its 30% lower FASB and with the lateral cortex exhibits 20% darker gray level (more longitudinal collagen) compared with the average of all other locations. Conversely, the remaining ("compression") cortices as a group have a high OPD, are more extensively remodeled, and contain more oblique-to-transverse collagen. The caudal cortices (caudomedial, caudal, caudolateral) are significantly thinner (P < 0.01) and have 4% lower mineral content (P < 0.05) than all other locations. Moderately strong correlations exist between collagen fiber orientation and normal strain (r = 0.752) and shear strain (r = 0.555). When normal and shear strains were transformed to their respective absolute values, thus eliminating the effects of strain mode (tension vs. compression), these correlation coefficients decreased markedly. CONCLUSIONS: Collagen fiber orientation is related to strain mode and may function to accentuate rather than attenuate bending. These differences may represent adaptations that function synergistically with bone geometry to promote a beneficial strain distribution and loading predictability during functional loading.

Adaptation, Physiological

Inability of energy dispersive X-ray analysis to identify particulate polyethylene.

There are limitations to all techniques used to identify particulate polyethylene in histological specimens. The goal of our study was to determine if remnant metal elements used during the catalytic production of ultra high molecular weight polyethylene, could be used as markers for particulate polyethylene detection in histological specimens. It was hypothesized that these catalyst elements could be detected in polyethylene using energy dispersive X-ray elemental analysis. Six samples from five different companies were evaluated. These included virgin polymer powder, polyethylene bar stock, and artificial joint components. Five specimens from each of the six samples were analyzed with energy dispersive X-ray elemental analysis. After elemental analysis was completed, only 2 of 30 specimens were positive for the catalyst elements. In the remaining 28 specimens, catalyst elements were not detected. Our investigation demonstrates that energy dispersive X-ray elemental analysis is not currently a feasible method of particulate polyethylene detection. Additional techniques will need to be developed to accurately identify particulate polyethylene in histological specimens.

Beryllium

Analysis of lymph nodes for polyethylene particles in patients who have had a primary joint replacement.

Polarized light microscopy has been used for more than forty years to identify polyethylene particles in histological specimens; however, few investigators have assessed the specificity of this technique. We examined specimens from dissected lymph nodes for the presence of strongly birefringent particles resembling polyethylene. Twenty-seven patients had dissection of lymph nodes after a total joint replacement (Group 1), and a control group of eighteen patients had dissection of lymph nodes before a total joint replacement (Group 2). Specimens from both groups of lymph nodes were examined under plain and polarized light. The presence of strongly birefringent particulate debris was graded from 0 to 4. Twenty-one (78 per cent) of the twenty-seven patients in Group 1 and eight of the eighteen patients in Group 2 had strongly birefringent particles in the lymph nodes. Our results demonstrate that, in the assessment of the systemic dissemination of polyethylene in the lymphoreticular system, polarized light microscopy has important limitations. More refined techniques employing polarized light and other methods of physical and chemical analysis may be necessary to identify polyethylene particles accurately within the lymphoreticular system and periprosthetic tissue.

Adult