PubMed HealthSearch

Biomedical subjects

R D Jenkins

Publications and source records attributed to R D Jenkins.

At least 19 recordsLinked to original sources

Medical resources on the Internet: searching and appraising.

Finding useful medical information on the Internet depends on searching effectively and critically appraising the resources when they are found. This article offers practical advice for those interested in using the internet for education and training.

Computer Communication Networks

Recurrent left ventricular false aneurysm.

A recurrent left ventricular false aneurysm 5 years after patch repair and causing progressive congestive heart failure was readily diagnosed by echocardiography and heart catheterization. Its substrate was suture dehiscence of undetermined origin. Urgent repair was successful. The long-term prognosis is guarded.

Aged

Laser balloon angioplasty: clinical, angiographic and histologic results.

Laser balloon angioplasty combines conventional coronary angioplasty with laser energy to transiently heat vascular tissue. Laser balloon angioplasty, was performed in 21 patients (aged 56 +/- 13 years), including 10 patients treated urgently after acute failure of conventional angioplasty and 11 patients treated with elective laser balloon angioplasty. Immediately after conventional angioplasty, laser doses (1 to 10 doses of 205 to 380 J each) were delivered during inflation of the laser balloon to a pressure of 4 atm. Seven (70%) of 10 patients with acute failure of conventional angioplasty were successfully treated with laser balloon angioplasty, but 3 (30%) were unsuccessfully treated with the laser procedure and required emergency coronary artery bypass surgery. In all three failures, the 3 mm laser balloon angioplasty catheter was not the optimal size for the vessel. In the 11 patients treated with elective laser balloon angioplasty (reference diameter 2.94 +/- 0.22 mm), the minimal luminal diameter increased from 0.45 +/- 0.25 to 1.85 +/- 0.46 mm after conventional angioplasty and to 2.44 +/- 0.29 mm after laser balloon angioplasty (p less than 0.001). This corresponded to a decrease in diameter stenosis from 84 +/- 9% before to 35 +/- 16% after conventional angioplasty and to 15 +/- 10% after laser balloon angioplasty (p less than 0.001). There were no instances of myocardial infarction, emergency coronary artery bypass surgery or death and no acute complications related to delivery of laser energy in this group. Follow-up coronary angiography was performed 5.5 +/- 1.1 months after laser balloon angioplasty in 18 patients discharged from the hospital after a successful procedure. Ten patients (56%) had angiographic restenosis, defined as recurrent diameter stenosis greater than 50%. Six patients were subsequently treated by directional coronary atherectomy, which revealed intimal proliferation indistinguishable from that in patients with restenosis after conventional angioplasty. In conclusion, laser balloon angioplasty may be effective in sealing severe coronary dissections and reversing abrupt closure associated with failed conventional angioplasty. After uncomplicated conventional angioplasty, laser balloon angioplasty improves immediate luminal dimensions, but restenosis appears to be mediated by intimal hyperplasia, similar to that seen after conventional angioplasty.

Angiography

Management of a child on CAPD with a ventriculoperitoneal shunt.

Long term dialysis in children with multiple handicaps has become easier with the advent of CAPD. In December 1986, an 11 year old with myelomeningocele in end stage renal disease secondary to chronic pyelonephritis required dialysis. Placement of a right ventriculoperitoneal shunt had been done at 4 months of age. Poor family compliance required placement in medical foster care. The peritoneal catheter was replaced three times. Leakage and infection were the major complications resulting in catheter replacement. In March 1988 the child required shunt extension due to accelerated growth after which she developed relapsing peritonitis requiring removal of the peritoneal catheter and externalization of the ventriculoperitoneal shunt. A proximal tap of the ventriculoperitoneal shunt prior to revision had a negative culture but glucose of 471 when serum glucose was 91. Six days after externalization of the shunt and catheter removal, the shunt was converted to ventriculoatrial and the PD catheter replaced. Nasogastic feedings and cycler dialysis became necessary due to worsening nutritional status and hyperabsorption. Successful transplantation occurred 28 months after initial dialysis.

Catheters, Indwelling

Laser balloon angioplasty. A new approach to abrupt coronary occlusion and chronic restenosis.

Abrupt coronary occlusion and long-term restenosis continue to be the major problems associated with percutaneous transluminal coronary angioplasty (PTCA). Laser balloon angioplasty (LBA) is a technique designed to potentially alleviate these problems by sealing arterial dissections, smoothing the luminal surfaces, dehydrating thrombi, and reducing the elastic properties that tend to recoil the stretched artery to its original state. During LBA, laser energy is delivered circumferentially by a 100-microns optical fiber that terminates in a central diffusing tip within an angioplasty balloon. LBA is performed for 20 seconds during the final inflation of the angioplasty balloon. Achieved with decremental ramped laser dosimetry, Nd:YAG laser energy has been shown to be effective in welding experimental arterial dissections over a therapeutic temperature range of 95 degrees-120 degrees C. LBA treatment of rabbit iliac arteries has been superior to balloon angioplasty in inhibiting elastic recoil and causing acute and long-term luminal increment. LBA has also been effective for sealing acute dissections in atherosclerotic rabbit iliac arteries. Additionally, in a canine model, safety in the coronary circulation has been shown, that is, even at 1 month after LBA, angiography demonstrated a cast of the LBA balloon without luminal compromise. Since March 1988, more than 250 patients with symptomatic coronary artery disease have been treated with LBA with nearly uniform clinical success, including frequent reversal of abrupt closure. LBA seems to be a safe modality that may decrease the need for emergency operative procedures and late coronary revascularization after PTCA.

Angiography

Laser balloon angioplasty versus balloon angioplasty in normal rabbit iliac arteries.

Reduction of vascular recoil is an important goal of laser balloon angioplasty (LBA), wherein Nd:YAG laser radiation is delivered radially during balloon inflation. To define the acute and chronic effects of LBA on the normal arterial lumen in comparison with those of balloon angioplasty (BA), 36 New Zealand White male rabbits (3-4 kg) were subjected to LBA of an external iliac artery and to BA of the contralateral artery with two 1-minute balloon inflations. During LBA, which was performed during the second balloon inflation, either 300 (n = 26) or 176 (n = 10) J were delivered to achieve high and moderate laser doses, respectively, in different LBA groups. Angiography was performed pre- and post-LBA/BA and subsequently at intervals of either 1, 2, 7, 28, 48, or 223 days. Automated analysis of digitized images was used to measure lumen diameter. No instance of perforation or thrombosis occurred. LBA-treated arteries acutely showed an increase in mean diameter over baseline (+ .5 mm, P less than .01) and that of BA-treated arteries (+ .4 mm, P less than .01). While arteries treated with the high laser dose showed a loss of the initial gain in lumen diameter by 1 month, caused by both extravascular fibrosis of the thinwalled (less than 0.1 mm) artery and mild neointimal proliferation which were not reduced by daily administration of aspirin in seven rabbits, arteries treated with the moderate laser dose retained the increment in mean diameter at 1 month over that of BA-treated arteries (+ .5 mm, P less than .05). Thus, unlike BA, LBA increases luminal diameter acutely and, at a moderate laser dose, chronically.

Angioplasty, Balloon

Laser balloon angioplasty: effect of tissue temperature on weld strength of human postmortem intima-media separations.

Dehiscence of portions of atheromatous plaques fractured during percutaneous transluminal coronary angioplasty may contribute to both abrupt reclosure and gradual restenosis. Laser balloon angioplasty has been shown to be effective in welding human plaque-arterial wall separations in vitro by heating tissues with a Nd:YAG laser during balloon inflation. To define the potentially useful therapeutic range of tissue temperature required to achieve thermal welds, 220 1-cm diameter discs of human postmortem atheromatous aortic tissue, the intimal plaque of which had been separated from the media, were exposed to 3-25 watts of Nd:YAG laser radiation delivered over a 12-mm2 nominal spot size for 20 seconds via a 400-micron core optical fiber. As measured with a thermistor, adventitial temperature reflected the temperature at the plaque-media junction to within 10 degrees C. The degree of tissue temperature elevation was related to delivered energy, while effective tissue penetration increased to maximum depth of 3 mm at the highest power density. Strength of tissue welds was defined as the force required to shear opposing layers of welded segments. Adventitial tissue temperatures below 80 degrees C were not associated with appreciable welds, while equilibrium temperatures between 95 degrees C and 140 degrees C were consistently associated with effective mean weld strengths, which increased linearly from 25 to 110 g, respectively. Temperatures greater than 150 degrees C were associated with rapid tissue dehydration and charring. These data suggest that the therapeutic range of tissue temperature that provides effective thermal fusion of intima-media separations is broad and that the depth and degree of thermal coagulation can be controlled by manipulation of laser energy delivery.

Angioplasty, Balloon

Laser balloon angioplasty: effect of constant temperature versus constant power on tissue weld strength.

Thermal fusion of intimal plaque with the arterial wall during coronary balloon angioplasty may significantly reduce the incidence of abrupt closure and may reduce the occurrence of delayed restenosis by improvement of luminal size and shape. Although Nd:YAG laser energy has been shown to be effective in the thermal fusion of plaque-arterial wall separations in vitro, the most efficient manner of energy delivery for rapid achievement of therapeutically useful equilibrium tissue temperature during laser exposure has not been defined. A comparison of weld strength achieved was therefore made between two formats of laser delivery: constant power vs. decremental power with an initial high dose followed by the minimal serial decrements necessary to maintain tissue temperature constant for 15 seconds. One hundred sixty-six tissue discs of human postmortem aorta of 11 mm diameter were studied. Intimal plaque was separated from the media, the two layers were juxtaposed, a force of 4 pounds was applied, and a fiberoptic-delivered laser beam was directed perpendicular to the tissue over a 3-mm-diameter nominal spot size. Weld strength was measured as the shear force required to separate completely the two tissue layers. The mean weld strength (75 g) achieved by use of the decremental power format was significantly higher (P less than .01) than the mean strength (32 g and 56 g) achieved by using constant power for 20 and 30 seconds, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

Angioplasty, Balloon

Laser balloon angioplasty: effect of exposure duration on shear strength of welded layers of postmortem human aorta.

Laser Balloon Angioplasty (LBA) is a technique that may improve the results of balloon angioplasty by thermally sealing arterial dissections and reducing elastic recoil. To define the relationship between laser-exposure duration and the strength of thermal welds made between separated layers of arterial wall, 360 1-cm discs of human postmortem aorta were lased for six different exposure intervals at three different temperature ranges, comparing shear strength of thermal welds in the different groups. Twenty discs were lased to achieve plateau adventitial temperatures of 95 degrees C-104 degrees C (group A), 105 degrees C-114 degrees C (group B), or 115 degrees C-124 degrees C (group C) at each of the exposure periods (5, 10, 15, 20, 25, and 30 sec). A 400-micron fiberoptic coupled to a 1.06 micron continuous wave neodymium:YAG laser was placed perpendicularly 8 mm above the luminal surface of each disc, which had been split midway between the intimal and adventitial surface and reapposed. Mean laser energy ranged 78-378 J delivered in a decremental stepwise fashion to achieve quickly and maintain the target plateau tissue temperature. Mean weld strength increased in relation to both achieved tissue temperature and laser-exposure duration, with at least 10 sec necessary, at temperatures greater than 95 degrees C, for reliable thermal welding. Laser exposure for greater than 20 sec provided no statistical increment in weld strength. In the anticipated clinical performance of LBA, these data suggest that when thermal fusion of disrupted arterial tissues is desired, a laser-exposure duration of 10-20 sec is optimal.

Angioplasty, Balloon

Plaque-media rewelding with reversible tissue optical property changes during receptive cw Nd:YAG laser exposure.

Laser dosimetry for thermal fusion of plaque-wall separations during laser balloon angioplasty (LBA) is dependent upon the optical properties of the atheromatous arterial wall during one or more exposures to cw Nd:YAG laser radiation. An integrating sphere technique was used to measure relative transmission and reflection continuously during irradiation of human postmortem atheromatous aortic sections. Tissue luminal surface temperature was recorded continuously with a thermographic video imager during repetitive 20-30-sec, 8-15-watt exposure of a 3-mm nominal spot. In all specimens, transmission fell progressively during each exposure by 10-70% of baseline values. This effect was reversible with normalization of transmission during the initial phase of each subsequent exposure. Changes in transmission were inversely related to temperature over a 50-170 degrees C range, whereas relative reflection remained constant. Accompanying reversible transmission changes was the observation that the weld strength of plaque-aortic wall separations was unchanged by repetitive laser welding and tissue separation of individual sections. In conclusion, temperature-dependent reversible optical and physical properties of plaque occur during exposure to 1.06 microns cw laser radiation.

Angioplasty, Balloon

The effect of activated charcoal on N-acetylcysteine absorption in normal subjects.

The discovery of the effectiveness of oral antidotes such as N-acetylcysteine (NAC) for acetaminophen poisonings has raised questions about the appropriateness of concomitant administration with activated charcoal. A number of studies have attempted to clarify this question without complete success. This study was designed to evaluate the difference in serum levels of NAC when given with activated charcoal. Nineteen patients completed a two-phase cross-over study in which they served as their own controls. Each subject in phase 1 received 140 mg/kg of diluted, chilled NAC orally, and venous blood samples were drawn for analysis. Phase 2 consisted of a 100-g dose of activated charcoal followed by NAC. Samples were transported immediately and assayed using spectrophotometry. A reduction in peak NAC level of 29% (P less than .02) and a reduction of total area under the curve (AUC) of 39% (P less than .001) was noted. Although it may be preferable to avoid completely the use of activated charcoal when using NAC to treat overdoses of acetaminophen, we recommend that if these agents are used together, doses of NAC be increased by 40% to compensate for the decreased oral absorption of NAC.

Absorption

Review of urine microscopy for bacteriuria.

Urine microscopy for bacteriuria remains a useful and valid technique for the evaluation of urinary tract infection; however, established interpretive criteria are not agreed on. Our own data and a review of the literature demonstrate that reliable data can be obtained by enumerating the organisms observed in stained or unstained centrifuged and stained uncentrifuged urine specimens. Criteria are given for the interpretation of urine microscopy for maximum sensitivity and specificity for each method reviewed. For clinicians desiring to perform urine microscopy, we recommend the use of oil-immersion microscopy of Gram-stained centrifuged urine sediment and suggest that observing at least one organism per oil-immersion field corresponds with 95% sensitivity and that observing more than five organisms corresponds with 95% specificity for bacteriuria at a level of 10(5) or more colony-forming units per milliliter. Further testing will be required on any negative specimen from a symptomatic patient.

Bacteriological Techniques

Early experience with continuous arteriovenous hemofiltration in critically ill pediatric patients.

The applicability of continuous arteriovenous hemofiltration (CAVH) for renal replacement therapy was evaluated in three infants and two young children with catastrophic medical and surgical illnesses. In the first four patients, CAVH was used in conjunction with either peritoneal or hemodialysis. In the fifth patient, CAVH was the sole renal replacement therapy employed; in this critically ill anuric infant, we were best able to evaluate the ability of CAVH to continuously control fluid, electrolyte, and acid-base balance, and allow the administration of adequate parenteral nutrition. The difficulties encountered were related to anticoagulation, establishment of adequate vascular access, and selection of an appropriate hemofilter for the performance of the technique. Despite the application of suction-assistance, we were unable to effectively employ a prototype pediatric hemofilter to attain a level of plasma ultrafiltration consistent with the objectives of therapy. However, we were able to effectively and safely employ an adult hemofilter for these purposes; modifications were made in the adult hemofilter system before its application in the smallest pediatric patients. Our experience suggests that, even in critically ill infants, CAVH can be successfully applied as an effective renal replacement therapy. However, further experience is required before its potential impact on patient survival can be assessed.

Acute Kidney Injury