PubMed HealthSearch

Biomedical subjects

R D Nawfel

Publications and source records attributed to R D Nawfel.

4 recordsLinked to original sources

Visualization and detection-localization on computed tomographic images.

These studies investigated observers' ability to detect and locate highly visible liver lesions on computed tomographic (CT) images, manipulating both the lesion's location and polarity (brighter or darker than liver background). Visibility of a lesion is not sufficient to guarantee accurate localization. With clinical images, possible confusions between a lesion and coexisting normal structures (like blood vessels) is a serious constraint on observer performance.

Humans

Size discrimination in computed tomographic images. Effects of feature contrast and display window.

Studies show that features on computed tomographic (CT) images in clinical formats become less detectable when the images are produced with wider CT display windows. We studied the effects of feature contrast and the display window on observer performance in higher-order tasks that involved discriminating small size differences between features on CT images. The features to be discriminated were pairs of disks (9.0 or 9.5 mm in diameter) superimposed on CT images of water phantoms. Sets of image stimuli for two different types of size-discrimination tasks were generated with various CT contrasts specified for the superimposed features and were produced on film transparencies with display windows ranging from 90 to 2880 Hounsfield units (HU) in width. Observers' performance improved with increasing CT contrast in both size discrimination tasks. Unlike performance in feature-detection tasks, however, size discrimination was unaffected by changing the CT display window over a factor of 16 (from 90 to 1440 HU). Performance fell only at the widest display window (2880 HU), for which CT noise was essentially invisible. These results suggest that the effect of changing the CT display window may depend on the spatial frequency content of image information required for a given task.

Humans

Contrast-detail curves for liver CT.

Contrast-detail curves were constructed for liver computed tomographic (CT) images using an objective method. Stimuli were created by superimposing disks at specified locations on sets of 92 normal liver CT images. Bright and dark disks of 9 sizes and 36 possible image contrasts were used. Sets of 92 stimuli were rendered on film at five window widths (64, 128, 256, 512, and 1024 HU). The contrast-detail (CD) curve flattened substantially for disks larger than 7-mm diameter, and its slope (on a log-log plot) was less than predicted from signal-detection theory. Manipulation of display window manipulation had little impact on this disks' visibility. The results indicate that human observers have difficulty visualizing large, low-contrast details on liver CT scans, and suggest that narrowing the display window will have little effect on this limitation.

Contrast Media

Evaluation of video gray-scale display.

Setting up and maintaining video display monitors properly will help to reduce display variation and improve overall presentation of the radiological image. Display monitor gray-scale characteristics were examined using the SMPTE test pattern. This test pattern may be used as a standard for adjusting brightness and contrast. The controls should be adjusted to display the full dynamic range so that the 5% and 95% signal levels in the pattern are visible. Measured luminance on a laboratory workstation used for radiological perceptual experiments, and on the Siemens CT gray-scale monitor was determined to range from 0.17 to 76.0 nit, and 0.17 to 24.66 nit, respectively. These were compared with the range of approximately 17 to 514 nit for a typical film-viewbox combination. Characteristic curves were determined for both monitors, and CRT gammas were 3.34 and 2.48 for the perceptual workstation and CT console, respectively. The display gamma was determined from fitting luminance data to a log-log plot of luminance versus input gray level. The usefulness of the SMPTE test pattern for visual presentation as well as photometric measurement is demonstrated.

Computer Terminals