PubMed Health⌕ Search

Biomedical subjects

R D O'Neill

Publications and source records attributed to R D O'Neill.

At least 19 recordsLinked to original sources

An amperometric glucose-oxidase/poly(o-phenylenediamine) biosensor for monitoring brain extracellular glucose: in vivo characterisation in the striatum of freely-moving rats.

Amperometric glucose biosensors based on the immobilization of glucose oxidase (GOx) on Pt electrodes with electropolymerized o-phenylenediamine (PPD) were implanted in the right striatum of freely-moving rats. Carbon paste electrodes for the simultaneous monitoring of ascorbic acid (AA) and/or tissue O2 were implanted in the left striatum. A detailed in vivo characterization of the Pt/PPD/GOx signal was carried out using various pharmacological manipulations. Confirmation that the biosensor responded to changing glucose levels in brain extracellular fluid (ECF) was obtained by intraperitoneal (i.p.) injection of insulin that caused a decrease in the Pt/PPD/GOx current, and local administration of glucose (1 mM) via an adjacent microdialysis probe that resulted in an increase in the biosensor current. An insulin induced increase in tissue O2 in the brain was also observed. Interference studies involved administering AA and subanaesthetic doses of ketamine i.p. Both resulted in increased extracellular AA levels with ketamine also causing an increase in O2. No significant change in the Pt/PPD/GOx current was observed in either case indicating that changes in O2 and AA, the principal endogenous interferents, have minimal effect on the response of these first generation biosensors. Stability tests over a successive 5-day period revealed no significant change in sensitivity. These in vivo results suggest reliable glucose monitoring in brain ECF.

Animals↗

Major differences in the behaviour of carbon paste and carbon fibre electrodes in a protein-lipid matrix: implications for voltammetry in vivo.

The widely documented differences in behaviour of carbon fibre electrodes (CFEs) and carbon paste electrodes (CPEs) used for neurochemical analysis in vivo were investigated. Differential staircase voltammetry was used to study the electrooxidation of ascorbic acid (AA) at CFEs and CPEs in the presence of major constituents of brain tissue, viz., protein, lipid or a mixture of both. Both electrode types were poisoned by protein, reflected in positive shifts in the AA voltammetric peak potential, and also peak broadening, following exposure of the electrodes to protein solution. In contrast, CFEs and CPEs responded very differently to exposure to lipid suspension: CFEs exhibited poisoning whereas CPEs showed enhanced electron transfer kinetics for AA. This significant difference in the response of the two carbon materials to lipid was further demonstrated by showing that lipid could reverse the poisoning caused by protein for CPEs but not CFEs. It appears, therefore, that proteins adsorb on both CPEs and CFEs, hindering electron transfer from AA to the electrode surface. Surfactant lipid molecules, in contrast, have a cleaning effect on CPEs, removing pasting oil and adsorbed proteins from the CPE surface. These results provide an explanation for the stability of CPEs in brain tissue and for the contrasting instability of CFEs in the same environment. The data also suggest that a lipid-protein matrix represents a valuable in vitro chemical model of brain tissue that should allow a truer characterisation in vitro of new and existing in vivo sensors, reducing the need for animal experiments in these studies.

Animals↗

Continuous monitoring of extracellular glucose concentrations in the striatum of freely moving rats with an implanted glucose biosensor.

We have used a glucose oxidase-based sensor implanted in the striatum of freely moving rats to determine the concentration of extracellular glucose in two distinct ways. With a modification of the zero net flux method, in which different concentrations of glucose are infused through a dialysis probe glued to the biosensor, we calculated the concentration at which there was no change in glucose current by regression analysis; this gave a concentration of 0.351 +/- 0.016 mM. Calculating the concentration from the basal current and the in vitro calibration of the biosensor was not significantly different from this. The basal extracellular glucose concentration determined by either method remained constant over a period of several days. Infusion of 50 microM veratridine through the adjacent dialysis probe caused a steep decrease in glucose current as soon as the drug reached the brain in contrast to the delayed fall (7.5 min) seen with microdialysis in previous experiments from this laboratory. These results demonstrate that this biosensor provides a direct, real-time measure of the extracellular concentration of glucose.

Animals↗

Monitoring brain chemistry in vivo: voltammetric techniques, sensors, and behavioral applications.

Clinical intervention in neurological disorders is almost invariably achieved using chemical agents that act on neuromediator-related sites, suggesting that intercellular chemical signaling plays a major role in determining the properties of neural networks. A variety of microvoltammetric sensors and techniques have been developed over the last 25 years to study neuromediators in intact brain in vivo, and in isolated tissues, for animal models of behavior and disease. This review, with over 600 citations, considers the advantages and limitations of the different approaches, including progress in biosensor design, illustrated by studies on the neurochemical bases of a wide variety of behaviors.

Animals↗

Biosensor for neurotransmitter L-glutamic acid designed for efficient use of L-glutamate oxidase and effective rejection of interference.

An amperometric biosensor for L-glutamic acid (Glu) was constructed by the adsorption and dip coating of L-glutamate oxidase (GluOx, 200 U ml-1 phosphate buffer, pH 7.4) onto 60-micron radius Teflon-coated Pt wire (1 mm exposed length). The enzyme was then trapped on the surface by electropolymerisation of o-phenylenediamine that also served to block electroactive interference. This procedure afforded electrodes with similar substrate sensitivity compared with the classical approach of immobilising enzyme from a solution of monomer, and represents an approximately 10,000-fold increase in the yield of biosensors from a batch of enzyme. A number of strategies were examined to enhance the sensitivity and selectivity of the Pt/PPD/GluOx sensors operating at 0.7 V versus SCE. Pre-coating the Pt with lipid and incorporation of the protein bovine serum albumin into the polymer matrix were found to improve the performance of the electrode. The sensors had a fast response time, high sensitivity to Glu, with an LOD of about 0.3 mumol l-1, and possessed selectivity characteristics suggesting that monitoring Glu in biological tissues in vivo may be feasible.

Amino Acid Oxidoreductases↗

Characterization of carbon paste electrodes in vitro for simultaneous amperometric measurement of changes in oxygen and ascorbic acid concentrations in vivo.

Differential-pulse amperometry, an established technique for the in vivo monitoring of dopamine in brain extracellular fluid (ECF), was extended to the simultaneous electrochemical detection of molecular oxygen (O2) and ascorbic acid (AA). Lipid-treated carbon paste electrodes (LCPEs) were characterized in vitro using this technique and found to be ideally suited for the detection of both compounds. For O2 reduction, two equally sized cathodic pulses were applied, the first from a resting potential at -150 to -350 mV, which corresponds to the foot of the reduction wave for O2 at LCPEs, and the second from -350 to -550 mV, which corresponds to the peak of the reduction wave. Following the same criterion, equally sized anodic pulses were then applied from -150 to +50 mV and from +50 to +250 mV for AA oxidation. The complete sequence of pulses for O2 and AA detection lasts 1 s. Interference by O2 with AA currents and vice versa was not a problem. Also, several compounds present in brain ECF were tested and shown not to interfere appreciably with the amperometric signal for either compound. The technique was tested in vivo, and results from behavioural stimulation, achieved by the application of tail pinch, support the conclusion of simultaneous independent detection of changes in O2 and AA at LCPEs.

Animals↗

On the significance of brain extracellular uric acid detected with in-vivo monitoring techniques: a review.

The concentration of uric acid [UA] in the extracellular fluid (ECF) estimated with in-vivo voltammetry and microdialysis data is compared for probes of different diameters from the day of implantation (acute) to several days (chronic) or even months after surgery. For small probes (diameter < 160 microns) the acute [UA] of ca. 5 microM decreased significantly to ca. 1 microM under chronic conditions. For larger probes (e.g., 320-microns diameter) the acute [UA] was also ca. 5 microM, but this value significantly increased to ca. 50 microM under chronic conditions. Associated with this difference in [UA], there were parallel differences in the extent of gliosis around the probes. These findings are discussed in terms of possible sources of extracellular UA and their implications for in-vivo monitoring techniques in behaving animals.

Animals↗

Effect of probe size on the concentration of brain extracellular uric acid monitored with carbon paste electrodes.

We have investigated further the anomalously high concentration of brain extracellular uric acid detected with in vivo sampling probes reported recently. The contribution by uric acid and 5-hydroxyindoleacetic acid (5-HIAA) to peak 2 recorded in rat striatum with chronically implanted carbon paste electrodes (CPEs) of different sizes was estimated by comparing peak current densities and the effect of the monoamine oxidase inhibitor pargyline. The concentration of uric acid in the extracellular fluid was some 50 times greater for 320-microns-diameter CPEs than for 160-microns-diameter electrodes, where the urate level was estimated at approximately 1 microM. The concentration of 5-HIAA was similar for 320-, 260-, and 160-microns-diameter CPEs. These data provide an explanation for the previously observed differences in 5-HIAA/urate ratios recorded with 320-microns-diameter CPEs and smaller carbon fibre electrodes. The results also indicate that chronically implanted sampling probes of diameter > 160 microns perturb the surrounding tissue, which produces uric acid by a mechanism yet unknown, although preliminary histological data suggest that glial cells may be involved.

Animals↗

Fixed versus removable microdialysis probes for in vivo neurochemical analysis: implications for behavioral studies.

The levels of several neurochemicals, i.e., uric acid (UA), dopamine (DA), dihydroxyphenylacetic acid, and 5-hydroxyindoleacetic acid, collected daily from the rat striatum with either fixed or removable microdialysis probes for 7 days after surgery were compared. The implantation of the fixed cannula was followed by a 10-fold increase in the UA content in the dialysates collected from the first day after surgery onward and by a steady decrease in dihydroxyphenylacetic acid levels, whereas those of DA remained fairly stable. With the removable cannula system, only a smaller, transient increase in UA during the first 3 days after surgery was observed, with no change in DA or monoamine metabolites. The glial reaction around the cannula tracks was assessed by both quantitative histological techniques and measuring the glutamine levels in the dialysates collected at the time of surgery and 7 days later. Both the glial cell number and nuclear size, as well as the glutamine outflow, were considerably larger in the animals implanted with the fixed probes. It is, therefore, likely that the UA levels in the dialysate reflect the glial reaction to the probe. The suitability of the removable probe system for behavioral experiments involving repeated microdialysis sampling was illustrated in an experiment showing that the DA release in the nucleus accumbens of male rats assessed daily at postsurgery days 5-10 was virtually identical in three alternating sessions of sexual behavior as was the smaller release of this neurotransmitter detected during intervening nonsexual social interactions.

3,4-Dihydroxyphenylacetic Acid↗

Sensor-tissue interactions in neurochemical analysis with carbon paste electrodes in vivo.

Characterization of voltammetric signals recorded with microelectrodes in the living brain is fraught with difficulties. In addition to being anatomically complicated, brain tissue presents the analytical electrochemist with a complex chemical environment that includes surfactants (lipids), electrode poisons (proteins), electrocatalysts such as glutathione and ascorbic acid, and a tissue matrix that both restricts mass transport to the electrode surface and reacts physiologically to the presence of the probe. Identification of electrochemical signals recorded in vivo with carbon paste electrodes is discussed in the context of these problems. This examination shows that modification of both the electrode surface by tissue, and of the tissue environment by the electrode have important implications for voltammetric signal analysis in vivo. Despite these problems, valuable data on the relationship between behaviour and chemical changes in the brain can be obtained using in vivo electrochemical techniques.

Animals↗

Anomalously high concentrations of brain extracellular uric acid detected with chronically implanted probes: implications for in vivo sampling techniques.

The height of peak 2, h2, recorded using linear sweep voltammetry with 350-micron-diameter carbon paste electrodes in rat striatum was measured from the day of implantation (day 0) to 4 months after surgery. The value of h2 was at a minimum on day 0 (0.6 +/- 0.2 nA; n = 20), rose sharply to a maximum on day 2 (6.3 +/- 0.9 nA; n = 12), and decreased to a stable level by day 7 (3.3 +/- 0.7 nA; n = 16), which lasted for 4 months (3.2 +/- 0.6 nA; n = 9). These changes were shown by microinfusion of uricase to be due to variations in the concentrations of extracellular uric acid, although h2 appears to have a small baseline contribution of approximately 0.3 nA from 5-hydroxyindoleacetic acid. The stable value of h2 recorded under chronic conditions was estimated to correspond to a minimal uric acid concentration of 50 mumol/L, which represents a 10-fold increase in the extracellular level of this purine metabolite compared with the initial (acute) value. Very similar results were obtained using a microdialysis technique that detected uric acid directly. These estimates of striatal uric acid concentration are in marked contrast to those obtained using 40-micron diameter carbon fiber electrodes, which showed a decrease from the acute preparation to less than 1 mumol/L under chronic conditions. Large values of h2 were also recorded with chronically implanted paste electrodes in the hippocampus and frontal cortex.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Stearate-modified carbon paste electrodes for detecting dopamine in vivo: decrease in selectivity caused by lipids and other surface-active agents.

Electrochemical characteristics of dopamine, ascorbic acid, and ferrocyanide measured with carbon-Nujol paste electrodes (CPEs) and stearate-modified carbon paste electrodes (SMEs) before and after treatment with either surfactant (Triton-X), lipid (phosphatidylethanolamine), or brain tissue indicate that the lipophilic nature of the brain destroys the selectivity of SMEs for dopamine by removing the hydrophobic elements from the electrode surface. Measurements of the degree and time-course of changes in surface capacitance of SMEs following contact with surface-active agents support this conclusion. The results suggest that SMEs cannot be used to detect dopamine unambiguously in vivo and emphasize the need to characterize electrochemical sensors in an environment similar to that of intended applications.

Carbon↗

Uric acid levels and dopamine transmission in rat striatum: diurnal changes and effects of drugs.

Carbon paste disc electrodes were used to detect voltammetrically changes in the extracellular concentration of the purine metabolite, uric acid, and the dopamine metabolite, homovanillic acid (HVA), in the striatum of unanaesthetized, unrestrained rats under a variety of conditions. The motor activity level for each rat was recorded between the electrochemical scans. In totally unperturbed animals, there was a significant correlation between the levels of the two metabolites during the bright, relatively inactive, period of the diurnal cycle. During much of the dark (active) phase of the cycle, however, the uric acid signal showed no significant change compared with the light-on period, in contrast to the HVA signal which showed a marked increase. Significant variations in the concentration of striatal uric acid were observed during the switch-over from light to dark and dark to light conditions. The unilateral infusion of gamma-aminobutyric acid, taurine and haloperidol into the substantia nigra caused increases in the height of both the uric acid and HVA peak in the ipsilateral striatum; the size of these changes showed a significant correlation. Variable changes occurred on the contralateral side where no correlation was observed. Intraperitoneal administration of the mixed dopamine-receptor agonist, apomorphine, and the mixed antagonist, haloperidol, did not affect striatal uric acid levels significantly. These results suggest that, although there are conditions where parallel changes in dopamine release/receptor-activation and uric acid levels do occur in the striatum, neither the release of dopamine nor activation of dopamine receptors need necessarily lead to changes in the extracellular concentration of uric acid.

Animals↗

The effects of anxiolytic and anxiogenic benzodiazepine receptor ligands on motor activity and levels of ascorbic acid in the nucleus accumbens and striatum of the rat.

The effects of the anxiolytic benzodiazepine flurazepam and the anxiogenic beta-carboline N-methyl-beta-carboline-3-carboxylate (FG 7142) were measured in unanaesthetised rats. Changes in motor activity, using a Doppler-shift microwave device, and in the extracellular concentration of ascorbate in the striatum and nucleus accumbens, using linear sweep voltammetry with carbon paste electrodes, were monitored continuously over a period of 7 days. Both motor activity and release of ascorbate were greater during the dark than the light period; regression analysis showed a high correlation coefficient for motor activity vs release of ascorbate. The two drugs caused similar changes in this diurnal pattern. A single intraperitoneal injection of either flurazepam or FG 7142 at the end of the light period was followed by a reduction in the nocturnal rise of motor activity and of levels of ascorbate in both the nucleus accumbens and striatum. However, whereas the correlation coefficient for motor activity vs the level of ascorbate in both the nucleus accumbens and striatum remained high after the injection of flurazepam, there was a breakdown of the correlation on the day after the injection of FG 7142, followed by recovery.

Animals↗

Dopamine in the basal ganglia and benzodiazepine-induced sedation.

The effects of the anxiolytic benzodiazepine flurazepam on motor activity and the turnover of dopamine were measured in rats. Changes in motor activity were measured using a doppler-shift device; changes in extracellular homovanillic acid (HVA), monitored by linear sweep voltammetry with carbon paste electrodes implanted in the striatum and nucleus accumbens and ex vivo measurements of changes in 3,4-dihydroxyphenylacetic acid/dopamine (DOPAC/DA) ratios in the striatum and nucleus accumbens were used as indices of changes in the turnover of dopamine. Injection of vehicle increased the nocturnal rise in the concentration of HVA and the ex vivo DOPAC/DA ratio in the nucleus accumbens. Injection of flurazepam decreased the nocturnal rise in HVA and DOPAC/DA ratio in the nucleus accumbens below control levels. There was also a decrease in the nocturnal rise in motor activity. Neither injection of vehicle nor injection of flurazepam caused changes in either the concentration of HVA or the DOPAC/DA ratio in the striatum. The correlation coefficient for motor activity compared to concentration of HVA remained high for the nucleus accumbens but was reduced for the striatum after administration of flurazepam. The results suggest that the sedative effect of flurazepam may be due to an action on the mesolimbic but not the nigrostriatal dopaminergic pathway.

3,4-Dihydroxyphenylacetic Acid↗