PubMed Health⌕ Search

Biomedical subjects

R D Roux

Publications and source records attributed to R D Roux.

6 recordsLinked to original sources

Antibiotic-loaded biodegradable bone cement for prophylaxis and treatment of experimental osteomyelitis in rats.

A biodegradable, particulate composite bone cement containing gentamicin and vancomycin was used for both treatment and prophylaxis of Staphylococcus aureus osteomyelitis in rats. Osteomyelitis was established by inoculating S. aureus into holes that were drilled in the proximal tibiae and were filled with polymethylmethacrylate (PMMA) cylinders. The cylinders were left in place for 3 weeks. The infections were serially evaluated by clinical and radiographic examination and by quantitative culture for colony forming units (CFUs) at the time the rats were killed. For treatment, cements containing antibiotic were implanted in animals that had established osteomyelitis and were left in place for an additional 3 weeks. Sites treated with biodegradable cement containing antibiotics exhibited significantly fewer CFUs in comparison with controls (p < 0.01). Sites treated prophylactically with the biodegradable cement developed no infections as evaluated by clinical or radiographic criteria or by quantitative culture. At this relatively early time, no significant difference in therapeutic effectiveness was found when either the biodegradable cement or PMMA was used as a carrier for antibiotics.

Animals↗

Antibiotic release from an experimental biodegradable bone cement.

An experimental biodegradable bone cement [poly(propylene fumarate)-methylmethacrylate] (PPF-MMA) has been compared in vivo with polymethylmethacrylate (PMMA) as a carrier agent for local release of antibiotics. This approach is potentially applicable to the treatment of chronic osteomyelitis where the clinical goal is to achieve sustained high concentrations of antibiotics locally in the infected bone. In our experiments, gentamicin- and vancomycin-impregnated cylindrical PMMA and PPF-MMA cement specimens were implanted subcutaneously in rats, and blood and wound fluid samples were obtained over a 2-week period. Antibiotic levels were determined using immunoassays, and microbiologic activity was confirmed with agar diffusion techniques. The biodegradable PPF-MMA cement achieved and maintained considerably higher wound antibiotic levels than did PMMA cement. Vancomycin levels for the PPF-MMA cement were greater than 20 times those for the PMMA cement at all sampling times from 24 h to 14 days. For both cements, the serum antibiotic concentrations remained safely below maximum levels recommended for parenteral therapy. Mechanical testing of the PPF-MMA cement showed that admixture of 3% by weight of antibiotic did not adversely affect material properties. We conclude that this experimental biodegradable bone cement (PPF-MMA) can be used as a carrier to achieve high sustained local levels and low serum levels of antibiotics. Because it is biodegradable and thus does not require a secondary procedure for removal, it has special potential for use in treatment of chronic osteomyelitis.

Administration, Topical↗

Effects of knee flexion on the structural properties of the rabbit femur-anterior cruciate ligament-tibia complex (FATC).

Many studies have been conducted to determine the biomechanical properties of the anterior cruciate ligament (ACL). The method of holding the femur-ACL-tibia complex (FATC) test specimen, the strain rate applied, the angle of knee flexion and the direction of the applied loads have an important effect on the outcome. It is felt that the tensile properties and strength of the ligament should be measured by applying the tensile force along the axis of the ligament. A versatile clamp was designed to accomplish this purpose. Fifty-seven rabbit knee specimens were tested at angles of flexion of 0 degrees, 30 degrees or 90 degrees. In addition, a comparative study of 25 pairs of rabbit legs were performed, whereby loading was either along the ligament or along the tibial axis. Cyclic hysteresis, ultimate load, energy absorbed, and stiffness were determined. The ultimate load values for the FATC decreased with increased knee flexion for those loaded along the tibial axis, while no such change was detected for FATC tested along the ligament axis. Other structural properties measured followed similar trends. It is concluded that the structural properties of the rabbit FATC change minimally with knee flexion (from 0 to 90 degrees) when loaded along the ligament axis, but decrease significantly with knee flexion when loaded along the axis of the tibia. Therefore, the data obtained in this field of study can be compared only if the direction of loading with respect to the ACL is similar.

Animals↗

The phenomenon of "ligamentization": anterior cruciate ligament reconstruction with autogenous patellar tendon.

Reconstruction of the anterior cruciate ligament (ACL) with patellar tendon (PT) is a common procedure for the symptomatic ACL-deficient knee. Questions regarding graft incorporation, viability, and nutrition of the transplanted tissue are of concern. This relates to the graft's response to its new intrasynovial milieu and new physical forces. These factors were studied in a rabbit model of ACL reconstruction using PT and were evaluated with histological and biochemical parameters with respect to time. A histological and biochemical metamorphosis of the grafted PT occurred in this study. Autografts demonstrated a gradual assumption of the microscopic properties of normal ACL; by 30 weeks postoperatively, cell morphology was ligamentous in appearance. Normally, type III collagen is not observed in PT, however, a gradual increase in its concentration was seen in the grafts; by 30 weeks its concentration (10%) was the same as in normal ACL. Similarly, glycosaminoglycans content increased from its normally low level in PT to that found in native ACL. Collagen-reducible crosslink analysis demonstrated that grafted tissue changed from the normal PT pattern of low dihydroxylysinonorleucine (DHLNL) and high histidinohydroxymerodesmosine (HHMD) to the pattern seen in normal ACL (high DHLNL and low HHMD) by 30 weeks. These data suggest that when PT is placed in the anatomic and environmental milieu of the ACL, a "ligamentization" of the grafted tissue results; also the autograft initially depends on synovial fluid nutrition, as revascularization occurs after 6 weeks.

Animals↗

Origin of replacement cells for the anterior cruciate ligament autograft.

A rabbit model for anterior cruciate ligament (ACL) reconstruction using autogenous avascular patellar tendon (PT) was utilized to study the early events of graft incorporation. Histological observations demonstrated that autografts were centrally acellular with a peripheral rim of cells at 2 weeks, a central focal proliferation of cells at 3 weeks, and a cellular homogeneous distribution by 4-weeks postoperation. Graft necrosis followed by cellular proliferation suggested that a different population of cells other than the native PT fibroblasts may be inhabiting the graft. The extrinsic contribution of cells was studied by selective destruction of native PT cells with liquid nitrogen immersion prior to reconstruction of the ACL. The intrinsic contribution of cells was evaluated by sequestration of the PT graft in a semipermeable membrane before it was used to reconstruct the ACL. Histological analysis of tissue that was liquid N2 treated, used as an autograft, and then harvested 3-weeks postoperation revealed fibroblastic incorporation of the graft. In contrast, no cells were observed in semipermeable membrane sequestered autografts. These data suggest that autogenous ACL autografts of PT origin are repopulated by cells of external origin. In vitro control studies that were carried out in parallel demonstrated that PT fibroblasts could survive in tissue culture, but not in the synovial environment of the ACL. This suggests that fibroblasts from different sources have different, tissue-specific nutritional requirements.

Animals↗

Structural behavior of the halo orthosis pin-bone interface: biomechanical evaluation of standard and newly designed stainless steel halo fixation pins.

The structural response of the halo orthosis pin-bone interface to transverse loading was evaluated on an Instron testing machine using fresh cadaver calvarium sections. Commercially available stainless steel (control) pins and newly designed stainless steel experimental pins were evaluated. Cyclic loading tests and load-to-failure tests were performed. Of the many designs tested, one pin demonstrated an improvement in structural properties at the pin-bone interface compared with the control pin. Furthermore, the new pin design was more resistant to insertional torque reduction when subjected to cyclic loading after insertions at 4 and 6 in-lb. Both the control and experimental pins exhibited improved structural behavior at 8 in-lb of insertional torque compared to the currently recommended 6 in-lb.

Biomechanical Phenomena↗