Development of an analytical method for penicillin G in bovine milk by liquid chromatography with ultraviolet-visible detection and confirmation by mass spectrometric detection.

A liquid chromatographic (LC) method with ultraviolet-visible photodiode array (UV-VIS PDA) detection was developed to measure penicillin G in bovine milk. A liquid chromatographic-mass spectrometric (LC-MS) procedure was divised to confirm the LC method. The method involved diluting milk with a drug-releasing solvent consisting of acetonitrile-methanol-water and ultrafiltration through a 10,000 dalton cutoff filter. Penicillin G was separated from other components in the ultrafiltrate by ion-paired LC using a reversed-phase microbore column eluted with a 25% acetonitrile solution. The LC method was confirmed by thermospray LC-MS. The detection limit for penicillin G determination in milk was estimated to be 10 ppb for LC with UV-VIS PDA and 100 ppb for LC-MS.

Animals↗

Countercurrent chromatography meets MS.

Interfacing countercurrent chromatography with thermospray mass spectrometry provides a new analytical tool for detecting nonvolatile, hydrophilic or thermally unstable bioactive natural products.

Countercurrent Distribution↗

Semi-quantitative method for high molecular weight neuropeptides by high-performance liquid chromatography/thermospray mass spectrometry.

High-performance liquid chromatography/thermospray mass spectrometry (HPLC/MS) was evaluated and optimized for the determination of beta- and gamma-endorphin. Thermospray spectra for the endorphins could be acquired under ion evaporation conditions, when a low vaporizor temperature (94 degrees C) and high source temperature are used. The spectra showed [M + H]+, [M + Hx-1 + Nax]+(x = 1-3) together with double charged ions. Positive ion detection exhibited higher ion currents than negative ion detection. Thermospray HPLC/MS was used to generate a linear calibration curve from 10 to 300 pmol. Thermospray displayed good run-to-run reproducibility (2-7%) and accurately measured spiked quantities of beta- and gamma-endorphin within 15% of the spiked values.

Amino Acid Sequence↗

Displacement of the bidentate malonate ligand from (d,l-trans-1,2-diaminocyclohexane)malonatoplatinum(II) by physiologically important compounds in vitro.

Previous studies of platinum(II) compounds with bidentate leaving ligands have emphasized the contrast between the stability of the bidentate leaving ligand in vitro (T1/2 greater than 11 days in water) and the apparent reactivity of these bidentate platinum compounds in vivo. However, none of these studies actually measured the stability of these compounds in tissue culture medium (or in any other reaction mixture resembling in vivo conditions). The experiments described in this paper were designed to measure the stability and fate of (d,l-trans-1,2-diaminocyclohexane)malonatoplatinum(II) [Pt(mal)(trans-dach)] in RPMI-1640 tissue culture medium. The T1/2 for displacement of the malonate ligand in this medium was 9.5 hr at 37 degrees. Of the inorganic anions present in the medium, chloride accounted for the greatest displacement of the malonate ligand. However, at the concentrations with which it is found in tissue culture medium and in blood, bicarbonate was nearly as effective as chloride at displacing the malonate ligand. This observation is of particular significance because the bicarbonatoplatinum complex is unstable and the bicarbonate displacement reaction appears to represent a major non-enzymatic pathway for the formation of the biologically active aquated platinum complexes. At the concentrations with which they occur inside the cell, phosphates may play a similar role. Of the amino acids present in the medium, glutathione and the sulfur-containing amino acids were 50- to 400-fold more effective at displacing the malonate ligand than the other amino acids in RPMI-1640 medium. In the case of methionine, the reaction with Pt(mal)(trans-dach) was shown to be a direct displacement (SN2) reaction at physiological methionine concentrations. When Pt(mal)(trans-dach) was incubated at 37 degrees for 24 hr in RPMI-1640 medium, the major transformation products formed were (d,l-trans-1,2-diaminocyclohexane)methionineplatinum(II) (38%), other amino acid-platinum complexes (19%), and (d,l,-trans-1,2-diaminocyclohexane)dichloroplatinum(II) (14%). Eleven percent of the Pt(mal)(trans-dach) remained intact. Mass spectrometry and 1H-NMR indicated that the (d,l-trans-1,2-diaminocyclohexane)methionineplatinum(II) complexes that formed in RPMI-1640 medium consisted of approximately 60% of the bidentate mono-methionine complex coordinated to platinum at the sulfur and alpha-amino positions and 40% of the bis-methionine complex, presumably coordinated at the sulfurs.(ABSTRACT TRUNCATED AT 400 WORDS)

Amino Acids↗

Application of high-performance liquid chromatography and thermospray high-performance liquid chromatography-mass spectrometry to the analysis and identification of 2',3'-dideoxyadenosine and its metabolite in biological media.

Reversed-phase high-performance liquid chromatographic (HPLC) procedures are described for determining the stability of 2',3'-dideoxyadenosine (DDA) in biological fluids at therapeutic dosages. The validated methodology uses both direct injection and solid-phase extraction techniques. Deamination of DDA to 2',3'-dideoxyinosine (DDI) in plasma by adenosine deaminase was monitored by HPLC, and the identification of DDI verified by thermospray HPLC-mass spectrometry. This methodology should prove useful in future studies concerning the stability and metabolism of dideoxynucleosides.

Adenosine Deaminase↗

Analysis of some metabolites of T-2 toxin, diacetoxyscirpenol and deoxynivalenol by thermospray high-performance liquid chromatography-mass spectrometry.

Detection and identification of mycotoxin metabolites is a very challenging task. In order to achieve adequate sensitivity and specificity an analytical technique must overcome serious matrix interferences. Gas chromatography-mass spectrometry (GC-MS) which has the sensitivity and specificity to detect and identify mycotoxin metabolites requires hydrolysis of conjugated metabolites as well as derivatization. Thermospray high-performance liquid chromatography-mass spectrometry (HPLC-MS) offers the sensitivity, specificity, and structural information to detect and identify some mycotoxin metabolites in fecal and urine samples without derivatization. The mycotoxins evaluated in this study include deoxynivalenol (DON), T-2 toxin, and diacetoxyscirpenol. The de-epoxy and hydroxy metabolites of each toxin and the glucuronide conjugate of DON were isolated, extracted, and analyzed to detect their occurrence in animals. The thermospray mass spectra of the toxins showed an [M + H]+ ion and numerous structurally significant fragment ions in the positive ion detection mode. Negative ion detection exhibited primarily [M + acetate]- cluster ions with less fragmentation than observed by positive ion detection. The operation of the interface in the filament-on mode greatly increased the sensitivity in both positive and negative ion detection mode. Detection limits of 50-500 pg injected on column are obtained for these toxins and their metabolites using multiple ion detection. The urine and fecal extracts from rats, hens, and cows did not interfere with the HPLC-MS analysis for the specific metabolites or the glucuronide conjugate.

Animals↗

Determination of prostaglandins, and other metabolites of arachidonic acid by thermospray HPLC/MS using post column derivatization.

Thermospray HPLC/MS analysis of the metabolites of arachidonic acid proved to be sensitive and specific. The compounds included were hydroxy-fatty acids (5-HETE, 12-HETE, and 15-HETE) and prostaglandins PGD2, PGE2, PGF2 alpha, PGA2, PGA1, TXB2, and 6-Keto-PGF1 alpha. Thermospray HPLC/MS analysis allows for simultaneous monitoring of each compound without the need for additional sample preparation or derivatization. The thermospray spectra for the metabolites exhibited [M + NH4]+ ions and fragment ions because of sequential loss of equivalents of H2O. HPLC/MS showed detection limits in the 0.5 to 5 ng range when using multiple ion detection for most of the metabolites. Post-column derivatization of these metabolites using trimethylanilinium hydroxide (TMAH) to form the methyl esters is also presented. This derivatization resulted in a gain in ion current by a factor of 3-6 for most compounds while adding potential specificity to the analysis. The thermospray spectra of the derivatives were nearly identical to the spectra of the free acid except the peaks were incremented by 14 daltons due to the methyl ester formation. The derivatization of the carboxylic acid group proved to be complete under thermospray conditions producing the maximum ion current and causing no compromise in operation of the interface.

Animals↗

Derivatization to improve thermospray HPLC/MS sensitivity for the determination of prostaglandins and thromboxane B2.

Derivatization of prostaglandins and thromboxane B2 using diethyl amino ethyl chloride and diethyl amino ethyl bromide improved thermospray HPLC/MS sensitivity. The derivatization was evaluated for prostaglandin A1, A2, D2, E2, F1 alpha, F2 alpha, and thromboxane B2. The derivatization reaction, thermospray operating conditions, and mode of detection were optimized to produce the most intense [M + H]+ or [M - H]- ions for the derivative. Derivatization was better than 99% complete in 1 hour at 75 degrees C. No thermal degradation of the prostaglandins was observed. Positive thermospray ionization proved the mode most sensitive, enabling detection from 10 to 300 pg of each prostaglandin under multiple ion detection. The thermospray spectra exhibited intense [M + H]+ ions for the derivative with a few fragment ions from sequential losses of water from the [M + H]+ ion. Detection of a prostaglandin metabolite in plasma over the concentration range from 3 ppm to 30 ppb was possible using this derivatization.

Chromatography, High Pressure Liquid↗

Analysis of candidate anticancer drugs by thermospray high-performance liquid chromatography-mass spectrometry and by high-resolution mass spectrometry.

Thermospray high-performance liquid chromatography-mass spectrometry (TSP-HPLC-MS) and direct probe high-resolution MS was used to analyze four candidate anticancer drugs. The techniques were used to confirm the identity of the bulk drug and to identify impurities. Analysis by TSP-HPLC-MS resulted in molecular weight information from the separated components using as little as 50 ng of each drug. The high-resolution direct probe MS analysis provided additional structural information and possible empirical formulas for the parent drugs and their impurities. The use of both of these complimentary techniques proved to be very specific for the detection of the anticancer drugs and for postulating the identity of impurities.

3-Deazauridine↗

Analysis of candidate anticancer drugs by thermospray high-performance liquid chromatography-mass spectrometry.

Thermospray high-performance liquid chromatography-mass spectrometry was used to confirm the identity of five bulk anticancer drugs, and in some cases, to identify drug impurities. Analysis resulted in both molecular weight and structural (fragment ions) information obtained from the full scan spectra of as little as 50 ng of each drug. The technique was also used to evaluate the chromatographic specificity of corresponding ultraviolet or refractive index high-performance liquid chromatographic detection in the presence of drug degradation products.

Antineoplastic Agents↗

Isomer identification by kinetic energy release measurements using the voltage pulsed collision cell technique in mass-analysed ion kinetic energy spectrometry.

The voltage pulsing of the collision cell on a mass-analysed ion kinetic energy spectrometer allows simultaneous kinetic energy release measurements for unimolecular (T(V)), collision-induced (TCID(V)) and composite unimolecular and collision-induced (Tcomp(V)) decomposition processes in the time frame of a capillary gas chromatographic peak. The information gained by voltage pulsing sometimes allows more reliable isomer identification than by kinetic energy release measurements made in the non-pulsing mode alone. Presented are T(V), TCID(V) and Tcomp(V), and the ratio of their intensities for a number of isomeric halogenated compounds.

Hydrocarbons, Halogenated↗

A comparison of thermospray and direct liquid introduction high-performance liquid chromatography/mass spectrometry for the analysis of candidate antimalarials.

The analysis of antimalarials by high-performance liquid chromatography (HPLC)/mass spectrometry demonstrates a new dimension in specificity along with increased sensitivity compared to conventional HPLC detection methods. Both direct liquid introduction and thermospray HPLC/mass spectrometry interfaces provided molecular weight information as well as characteristic fragment ions for antimalarials not normally amenable to direct probe or gas chromatographic/mass spectrometric techniques. The direct liquid introduction interface, which incorporated a 1/100 split, showed a detection limit of 30 ng using selected ion monitoring. The thermospray technique showed less than 1 ng detection limits using selected ion monitoring.

Animals↗

Pharmacokinetics of oral methamphetamine and effects of repeated daily dosing in humans.

The pharmacokinetics of orally administered S-(+)-methamphetamine-d3 were investigated in human male volunteers before and after a 13-day course of a slow release form of S-methamphetamine hydrochloride. A one-compartment pharmacokinetic model incorporating a lag time fits the data best. The average elimination half-life was 10.1 hr (range of 6.4-15.1 hr). There were no statistically significant differences in pharmacokinetic parameters when a low dose (0.125 mg/kg) was given before and after the 13-day oral regimen. When a higher challenge dose (0.250 mg/kg) was used, the maximum plasma concentration of methamphetamine-d3 was slightly but significantly greater when the test dose was given at the end of the oral dosing period than when it was given at the beginning. Although minor differences in pharmacokinetics occur after subchronic treatment with low doses of methamphetamine, their result would be to increase plasma concentration of the drug. Therefore, development of pharmacodynamic tolerance to methamphetamine could not be explained on the grounds of a change in pharmacokinetics.

Administration, Oral↗

Simultaneous multiresidue analysis of beta-lactam antibiotics in bovine milk by liquid chromatography with ultraviolet detection and confirmation by electrospray mass spectrometry.

A multiresidue analytical method was developed for the simultaneous determination of amoxicillin, cephapirin, procaine penicillin G, ampicillin, cloxacillin, and ceftiofur in bovine milk. The method involved ultrafiltration of milk diluted with an equal volume of 50% acetonitrile through a 10,000 dalton molecular mass cutoff filter. Separation of these beta-lactam antibiotics from other milk components was performed by ion-paired (octane- and dodecanesulfonate) liquid chromatography using a phenyl column eluted with acetonitrile-water solution. Ultraviolet absorbance of the column effluent was monitored in the 200-350 nm range of a photodiode-array detector. For quantitation, the chromatograms were acquired at lambda 210 nm for penicillin G, ampicillin, and cloxacillin; lambda 230 nm for amoxicillin; and lambda 290 for cephapirin, procaine, and ceftiofur. The limit of detection for the simultaneous determination of these antibiotics was estimated to be 100 ppb. Liquid chromatography/electrospray mass spectrometry could be used to confirm these antibiotics for quantities down to 100 pg entering the mass spectrometer.

Animals↗