PubMed Health⌕ Search

Biomedical subjects

R Dumas

Publications and source records attributed to R Dumas.

At least 19 recordsLinked to original sources

Hepatitis A vaccination of Argentinean infants: comparison of two vaccination schedules.

BACKGROUND: Early immunization to protect infants against hepatitis A (HA) is recommended in intermediate or high endemic areas of the world, but little is known of the effects of maternal antibodies on the immune response. We studied the immunogenicity and reactogenicity of an inactivated HA vaccine administered in two different schedules to 2-month-old infants in an intermediate/high endemic area in Argentina. METHODS: In this double-blind, randomized study 131 infants received either three doses (at 2, 4, 6 months of age [Group A]) or one dose (at 6 months of age [Group B]) of the pediatric inactivated HA vaccine, Avaxim 80, and a booster dose at 15-18 months. HAV antibodies were measured (ELISA) at 2, 7, 15-18 and 16-19 months of age. Immediate (30 min after injection) and solicited local and systemic reactions were recorded for 7 days after each injection. RESULTS: Of 107/131 subjects (81.6%) who completed the study and who provided final serum samples after booster dose, 94 (87.8%) were seropositive at enrolment (>20 mIU/mL) with geometric mean concentrations (GMC) of 2989 and 3637 mIU/mL in Groups A and B, respectively. One month post-booster GMCs were 8236 mIU/ml (95% CI; 6304, 10760) and 1687 mIU/ml (1148, 2479) in Groups A and B, respectively, with 100% seroprotection. CONCLUSIONS: The HA vaccine was well tolerated and induced immunological priming in both groups during the first year of life in spite of the presence of maternal antibodies. Post-booster GMCs achieved after one or three primary doses suggest a long-term protection against HA.

Argentina↗

Adjustments to McConville et al. and Young et al. body segment inertial parameters.

Body segment inertial parameters (BSIPs) are important data in biomechanics. They are usually estimated from predictive equations reported in the literature. However, most of the predictive equations are ambiguously applicable in the conventional 3D segment coordinate systems (SCSs). Also, the predictive equations reported in the literature all include two assumptions: the centre of mass and the proximal and distal endpoints are assumed to be aligned, and the inertia tensor is assumed to be principal in the segment axes. These predictive equations, restraining both position of the centre of mass and orientation of the principal axes of inertia, become restrictive when computing 3D inverse dynamics, when analyzing the influence of BSIP estimations on joint forces and moments and when evaluating personalized 3D BSIPs obtained from medical imaging. In the current study, the extensive data from McConville et al. (1980. Anthropometric relationships of body and body segment moments of inertia. AFAMRL-TR-80-119, Aerospace Medical Research Laboratory, Wright-Patterson Air Force Base, Dayton, Ohio) and from Young et al. (1983. Anthropometric and mass distribution characteristics of the adults female. Technical Report AFAMRL-TR-80-119, FAA Civil Aeromedical Institute, Oklaoma City, Oklaoma) are adjusted in order to correspond to joint centres and to conventional segment axes. In this way, scaling equations are obtained for both males and females that provide BSIPs which are directly applicable in the conventional SCSs and do not restrain the position of the centre of mass and the orientation of the principal axes. These adjusted scaling equations may be useful for researchers who wish to use appropriate 3D BSIPs for posture and movement analysis.

Adult↗

Influenza vaccination of healthcare workers: a literature review of attitudes and beliefs.

BACKGROUND: Influenza vaccination coverage among healthcare workers (HCW) is insufficient despite health authority recommendations in many countries. Numerous vaccination campaigns encouraging HCW to be vaccinated have met with resistance. We reviewed published influenza vaccination programs in healthcare settings to understand the reasons for their success and failure, as well as the attitudes and beliefs of HCW. METHODS: Relevant articles published up to June 2004 were identified in the MEDLINE/Pubmed database. RESULTS: Thirty-two studies performed between 1985 and 2002 reported vaccination rates of 2.1-82%. Vaccination campaigns including easy access to free vaccine and an educational program tended to obtain the highest uptake, particularly in the USA. Yet, even this type of campaign was not always successful. Two main barriers to satisfactory vaccine uptake were consistently reported: (1) misperception of influenza, its risks, the role of HCW in its transmission to patients, and the importance and risks of vaccination (2) lack of (or perceived lack of) conveniently available vaccine. CONCLUSION: To overcome these barriers and increase uptake, vaccination campaigns must be carefully designed and implemented taking account of the specific needs at each healthcare institution.

Attitude to Health↗

Endoscopic argon plasma trimming of biliary and gastrointestinal metallic stents.

BACKGROUND AND STUDY AIMS: The aim of this study was to assess the feasibility and efficiency of plasma argon trimming of gastrointestinal and biliary metallic stents. PATIENTS AND METHODS: A total of 31 patients underwent plasma argon trimming of their metallic stents (14 women, 17 men; mean +/- SD age 73 +/- 12.2 years, range 46 - 96 years). Of these 31 patients, 24 had had covered or noncovered Unistep Wallstents placed in the biliary tract (13 patients with pancreatic neoplasms, five patients with Vater ampulloma, five patients with biliary tract carcinoma and one patient with chronic calcifiying pancreatitis); three patients had noncovered Enteral Unistep Wallstents (pyloroduodenal); two patients with obstructive colorectal carcinoma had a noncovered Bard Memotherm stent inserted; and two patients had noncovered Ultraflex stents placed for esophageal carcinoma. Endoscopic trimming of the stents was performed under propofol-induced general anesthesia, with the power set at 70 - 80 watts and an argon flow of 0.8 liters/minute. RESULTS: Complete and satisfactory trimming of the stents was possible, without complications (mean follow-up 15.8 months), in all patients except one, a patient with a covered biliary Wallstent. In 13 patients with biliary or Enteral Wallstents the trimming procedure was preventive. In eight patients with ulceration and/or hemorrhage (duodenal or rectal), healing was achieved after stent trimming and epinephrine (adrenaline) injection followed by electrocoagulation. Stent trimming restored patency of the duodenal lumen in six patients and of the esophageal lumen in two patients, and was done to allow insertion of a biliary stent in one patient whose duodenal stent was covering the papilla. In one patient with rectal tenesmus, stent shortening resulted in complete resolution of symptoms. CONCLUSIONS: Endsocopic plasma argon trimming of metallic stents is an efficient procedure which allows easy, reproducible and well-tolerated correction of complications that arise due to these prostheses.

Aged↗

Finite element simulation of spinal deformities correction by in situ contouring technique.

Biomechanical models have been proposed in order to simulate the surgical correction of spinal deformities. With these models, different surgical correction techniques have been examined: distraction and rod rotation. The purpose of this study was to simulate another surgical correction technique: the in situ contouring technique. In this way, a comprehensive three-dimensional Finite Element (FE) model with patient-specific geometry and patient-specific mechanical properties was used. The simulation of the surgery took into account elasto-plastic behavior of the rod and multiple moments loading and unloading representing the surgical maneuvers. The simulations of two clinical cases of hyperkyphosis and scoliosis were coherent with the surgeon's experience. Moreover, the results of simulation were compared to post-operative 3D measurements. The mean differences were under 5 degrees for vertebral rotations and 5 mm for spinal lines. These simulations open the way for future predictive tools for surgical planning.

Adult↗

Aventis Pasteur vaccines containing inactivated hepatitis A virus: a compilation of immunogenicity data.

Inactivated hepatitis A vaccines were developed in the 1980s and were introduced during the early 1990s. The Aventis Pasteur (AvP) inactivated hepatitis A virus antigen is used in several different vaccine formulations licensed for adults and children. Presented here are the immunogenicity results compiled from 37 clinical trials performed in 20 different countries between 1991 and 2001 in which these vaccines were administered to adults (16 years of age and over), children (aged 12 months-17 years), and infants (younger than 12 months). The accumulated clinical experience with these hepatitis A virus-containing vaccines demonstrates the excellent immunogenicity of this antigen in a wide range of situations. As with other licensed inactivated hepatitis A vaccines, immunological priming is achieved in virtually all vaccinees after a single-dose primary immunization, and it may be reinforced by a booster vaccination administered 6-36 months after the primary vaccination.

Adolescent↗

Validation of the relative 3D orientation of vertebrae reconstructed by bi-planar radiography.

The three dimensional (3D) reconstruction of the spine can be obtained by stereoradiographic techniques. To be safely used on a routine clinics basis, stereoradiography must provide both accurate vertebral shape and coherent position. Although the accuracy of the reconstructed morphology of the vertebrae is well documented, only few authors studied the accuracy of the vertebral orientation. Therefore, this paper focuses on the evaluation of the orientation accuracy of the reconstructed vertebrae (obtained by non-stereo corresponding point technique) considering either a 178 point vertebral model or a 6 point vertebral model (previously proposed in the literature). Five dried vertebrae were fixed on holders containing four markers each. The 3D reconstruction of both vertebrae and markers were obtained by stereoradiographic techniques. Using least square method matching from one position to another, the relative orientation was computed for the vertebral models (6 or 178 points) and the four markers. These vertebral and holder orientations were compared (considering the holder's one as reference). The repeatability of these relative orientations (vertebrae and holders) was also evaluated. The mean (RMS) orientation error of 178 point vertebral model was 0.6 degrees (0.8 degrees ), for lateral rotation, 0.7 degrees (1.0 degrees ) for sagittal rotation and 1.4 degrees (1.9 degrees ) for axial rotation. The intra-observer repeatability was 0.5 degrees (0.7 degrees ) for lateral rotation, 0.7 degrees (0.8 degrees ) for sagittal rotation and 0.9 degrees (1.2 degrees ) for axial rotation. The orientation was found more accurate and precise when using the 178 point vertebral model than when using the basic 6 point vertebral model. The relative orientation (in post-operative follow-up with respect to the pre-operative examination) of the vertebrae of one scoliotic patient was performed as an example of clinical application. The stereoradiographic method is a reliable 3D quantitative tool to assess the spine deformity, that can be used in clinics for the follow-up of scoliotic patients.

Adult↗

A 3D generic inverse dynamic method using wrench notation and quaternion algebra.

In the literature, conventional 3D inverse dynamic models are limited in three aspects related to inverse dynamic notation, body segment parameters and kinematic formalism. First, conventional notation yields separate computations of the forces and moments with successive coordinate system transformations. Secondly, the way conventional body segment parameters are defined is based on the assumption that the inertia tensor is principal and the centre of mass is located between the proximal and distal ends. Thirdly, the conventional kinematic formalism uses Euler or Cardanic angles that are sequence-dependent and suffer from singularities. In order to overcome these limitations, this paper presents a new generic method for inverse dynamics. This generic method is based on wrench notation for inverse dynamics, a general definition of body segment parameters and quaternion algebra for the kinematic formalism.

Acceleration↗

A silver sulphadiazine-impregnated lipidocolloid wound dressing to treat second-degree burns.

OBJECTIVE: To evaluate the efficacy and tolerance of Urgotul SSD dressing (Laboratoires Urgo) in the treatment of second-degree burns. METHOD: This was a national multicentre phase III non-comparative open-label prospective study involving 10 burns units. The 41 subjects were non-immunosuppressed adults with second-degree thermal burn(s), which were clinically non-infected, less than 24 hours old, had a surface area less than 500 cm2 and warranted the local use of silver sulphadiazine. For four weeks, subjects were followed up weekly with a clinical assessment, bacteriological swabs and photographic recording. RESULTS: Of the 41 patients, 24 healed within a mean of 10.8 days and 13 had a skin graft on the study burn within a mean of 11.5 days. There were four premature study withdrawals. The total number of cumulative treatment days was 445, and 298 treatments were performed (including 257 dressing changes). Mean dressing wear time was 1.73 days. None of the subjects acquired a secondary infection. Researchers took 121 bacteriological samples, and wound colonisation with Staphylococcus aureus was found in only one patient. At follow-up nursing staff reported that dressing acceptability was good. CONCLUSION: Use of Urgotul SSD led to a good wound outcome--wounds healed or were grafted.

Adult↗

Variability of the spine and pelvis location with respect to the gravity line: a three-dimensional stereoradiographic study using a force platform.

Analyzing standing posture requires a precise measure of the orientation of the various body segments with respect to the gravitational vector. We studied the posture variability of 34 healthy upright standing subjects. Using a force platform combined with a powerful stereoradiographic technique, we acquired the spine and pelvis three-dimensional (3D) geometry and located it with respect to the gravity line. For our data set, the mean 3D distance between the geometrical center of each vertebral body and the gravity line was 28 mm with a standard deviation of 5.6 mm. The vertebrae location variability, defined as plus or minus twice the mean standard deviation, was +/-40 mm in the sagittal plane and +/-25 mm in the frontal plane. The line connecting the middle of the external acoustic meatus (center of both acoustic meati: CAM) to the middle of the bi-coxo-femoral axis (hip axis: HA) was almost vertical. Its mean distance to the gravity line was 30 mm. Our data show a left lateralization, with respect to the gravity line, of the "Head-Spine-Pelvis" segments. The mean distance was 7.6 mm (SD 1.6 mm). This might be due to uneven partitioning of the body mass on each side of the sagittal plane.

Adult↗

Explicit calibration method and specific device designed for stereoradiography.

The three-dimensional geometry of the human spine is noteworthy information that can be obtained by stereoradiographic methods. These methods are based on the identification of anatomical structures in several views which are obtained by rotation of a patient standing on a turntable. Calibration algorithms for computer vision or photogrammetry are well documented, but they generally yield calibration devices which are cumbersome for the use in clinical stereoradiography. This paper presents a calibration method adapted to a two-view stereoradiography calibration (frontal and lateral incidences) and based on a simplified geometric modeling of the radiological environment. The a priori knowledge yields four calibration equations related to the vertical and horizontal planes of both views, leading to a specific calibration procedure and device. Moreover this device is attached to the stereoradiographic system (directly integrated on the turntable) in order to facilitate clinical applications. A validation was performed on 26 dried lumbar vertebrae in order to evaluate clinical situation. The mean accuracy of the stereoradiographic reconstruction was 1.2mm.

Aged↗

Urgotul: a novel non-adherent lipidocolloid dressing.

Urgotul belongs to a new class of non-adherent dressings: the lipidocolloid dressings. It is composed of an open weave polyester mesh impregnated with hydrocolloid polymers dispersed within petrolatum. The first clinical trial data are presented. Efficacy and safety were evaluated in a multicentre non-comparative trial involving 92 patients treated to healing or up to 4 weeks. Adult outpatients with acute wounds (n = 34), leg ulcers (n = 24), other chronic wounds (n = 14) or with second-degree burns (n = 20) were included. Results showed 32.4% (n = 11) of the acute wounds, 12.5% (n = 3) of the leg ulcers and 14.3% (n = 2) of the other chronic wounds completely healed before 4 weeks. Surface areas decreased on average by 76.4%, 63.5% and 44.2% at study endpoint respectively. For burns, 19 patients healed (95%) within 5-19 days. A total of 771 dressing changes were performed during the course of the study. Dressing application was considered as easy or very easy in 90% or more of the changes and there was no difficulty in removing the dressing in about 95% of the cases. Safety was good with five reports of a transitory local adverse event, probably dressing-related, being observed, two patients (2.2%) prematurely stopped treatment because of moderate periwound erythema. Urgotul is a highly promising new dressing which is currently undergoing further comparative clinical evaluation.

Adult↗

Simplified calibration system for stereoradiography in scoliosis.

Stereoradiography is a well known method to obtain 3D images of the spine and the thorax. The main algorithm used is the DLT, which is a very general one yielding to 11 implicit parameters per view. In order to calibrate the geometrical configuration of the stereoradiographic setup with this algorithm, there is a need of a wide calibrating object, leading to systems hard to use in clinical practice. The aim of this work was to modify the algorithm in order to simplify the calibration object. We used assumptions related to the specific case of stereoradiography, which reduced the problem of calibration to only 6 independent explicit parameters. A geometrical calibration performed plane by plane enabled to design a singular calibration object composed of steel balls along two vertical lines and three horizontal ones. A simulation of real configuration both for the previous method and the current algorithm associated to the singular calibrating object give for thirty 3D points a 2 RMS (95% confidence interval) error of reconstruction of respectively 0.6 and 0.3 mm. This study yielded to the transfer in clinics of two simplified systems of calibration which will be easier to use in clinical practice.

Calibration↗

Pre and post 3D modeling of scoliotic patients operated with in situ contouring technique.

A three-dimensional segmental analysis was performed on the stereoradiographic reconstructions of ten right thoracic scoliotic patients. From the quantitative model of the spine and pelvis, the vertebral and intervertebral orientations were computed pre and post operatively. These orientations allow to determine the apical and junctional zones of the high thoracic, thoracic and lumbar curves. The apical zone corresponds to the maximum of vertebral axial rotation. Pre operatively, the tendency was T7 for the thoracic transverse apex with 20 AE of axial rotation. The junctional zone corresponds to the maximum of vertebral lateral rotation and the maximum of intervertebral axial rotation. The tendency was T5 and T12 for the junctional vertebrae of the thoracic curve with, at both levels, 30 AE of vertebral lateral rotation and 10 AE of intervertebral axial rotation. The surgical correction obtained by in situ contouring technique was evaluated through these 3D orientations. The vertebral axial rotation at the high thoracic, thoracic and lumbar apex was corrected with respectively 52%, 60% and 60%.

Adolescent↗

MAD on threonine synthase: the phasing power of oxidized selenomethionine.

The use of selenomethionine and anomalous dispersion has become the most widely used way of solving the phase problem for de novo protein structure determination. In this paper, MAD data collected from oxidized and reduced selenomethionine-containing protein are described, and it is shown that oxidized selenomethionine has a very strong phasing power and can be efficiently used if the oxidation is uniform. The comparison was performed on threonine synthase crystals. For example, the phasing power of the oxidized data is doubled for the dispersive signal and is 20% stronger for the anomalous signal at the peak wavelength. The strength of the anomalous signal can be used to improve the signal when a protein contains few methionines or for single anomalous dispersion. The oxidation of some selenomethionines shows in the electron-density map through the presence of water molecules within hydrogen-bonding distance of the putative O atom.

Arabidopsis↗

Endoscopic treatment of pancreatico-biliary malignancies.

Biliary obstructions, due to pancreatic cancer and cholangiocarcinoma, have an ominous prognosis. At the time of diagnosis, most patients are beyond any curative treatment. Palliative therapies, such as transhepatic biliary drainage, bypass surgery, and endoscopy, have an established role in the management of such patients. Endoscopic retrograde cholangio-pancreatography (ERCP) plays a key role, allowing diagnosis, collection of cytologic and bioptic specimens, and insertion of large-bore biliary stents. The major drawback of plastic stents is the high rate of clogging, requiring frequent stent exchange. In the 1990s, self-expanding metal stents (SEMS) were developed and randomized studies have shown their superiority over plastic stents. SEMS can be successfully used in patients with hilar tumors. Duodenal obstruction due to biliopancreatic neoplasms can also be managed endoscopically. ERCP can be performed on an outpatient basis in selected patients, reducing costs related to hospitalization. A team approach is mandatory to obtain the best results.

Biliary Tract Neoplasms↗