PubMed Health⌕ Search

Biomedical subjects

R E Lenkinski

Publications and source records attributed to R E Lenkinski.

At least 19 recordsLinked to original sources

A systematic literature review of magnetic resonance spectroscopy for the characterization of brain tumors.

BACKGROUND AND PURPOSE: Proton MR spectroscopy ((1)H-MR spectroscopy) is a potentially useful adjunct to anatomic MR imaging in the characterization of brain tumors. We performed an updated systematic review of the evidence. METHODS: We employed a standardized search strategy to find studies published during 2002-2004. We reviewed studies measuring diagnostic accuracy and diagnostic, therapeutic, or health impact of (1)H-MR spectroscopy. We abstracted information on study design, (1)H-MR spectroscopy technique, and methodologic quality. We categorized studies into 5 subgroups: (1) metastasis versus high-grade tumor; (2) high-versus low-grade tumor; (3) recurrent tumor versus radiation necrosis; (4) tumor extent; and (5) tumor versus non-neoplastic lesion. RESULTS: We identified 26 studies evaluating diagnostic performance, diagnostic impact, or therapeutic impact. No articles evaluated patient health or cost-effectiveness. Methodologic quality was mixed; most used histopathology as the reference standard but did not specify blinded interpretation of histopathology. One large study demonstrated a statistically significant increase in diagnostic accuracy for indeterminate brain lesions from 55%, based on MR imaging, to 71% after analysis of (1)H-MR spectroscopy. Several studies have found that (1)H-MR spectroscopy is highly accurate for distinguishing high- and low-grade gliomas, though the incremental benefit of (1)H-MR spectroscopy in this setting is less clear. Interpretation for the other clinical subgroups is limited by the small number of studies. CONCLUSION: The current evidence on the accuracy of (1)H-MR spectroscopy in the characterization of brain tumors is promising. However, additional high-quality studies are needed to convince policy makers. We present guidelines to help focus future research in this area.

Astrocytoma↗

RF tumour ablation: computer simulation and mathematical modelling of the effects of electrical and thermal conductivity.

This study determined the effects of thermal conductivity on RF ablation tissue heating using mathematical modelling and computer simulations of RF heating coupled to thermal transport. Computer simulation of the Bio-Heat equation coupled with temperature-dependent solutions for RF electric fields (ETherm) was used to generate temperature profiles 2 cm away from a 3 cm internally-cooled electrode. Multiple conditions of clinically relevant electrical conductivities (0.07-12 S m-1) and 'tumour' radius (5-30 mm) at a given background electrical conductivity (0.12 S m-1) were studied. Temperature response surfaces were plotted for six thermal conductivities, ranging from 0.3-2 W m-1 degrees C (the range of anticipated clinical and experimental systems). A temperature response surface was obtained for each thermal conductivity at 25 electrical conductivities and 17 radii (n=425 temperature data points). The simulated temperature response was fit to a mathematical model derived from prior phantom data. This mathematical model is of the form (T=a+bRc exp(dR) s(f) exp(g)(s)) for RF generator-energy dependent situations and (T=h+k exp(mR)+n?exp(p)(s)) for RF generator-current limited situations, where T is the temperature (degrees C) 2 cm from the electrode and a, b, c, d, f, g, h, k, m, n and p are fitting parameters. For each of the thermal conductivity temperature profiles generated, the mathematical model fit the response surface to an r2 of 0.97-0.99. Parameters a, b, c, d, f, k and m were highly correlated to thermal conductivity (r2=0.96-0.99). The monotonic progression of fitting parameters permitted their mathematical expression using simple functions. Additionally, the effect of thermal conductivity simplified the above equation to the extent that g, h, n and p were found to be invariant. Thus, representation of the temperature response surface could be accurately expressed as a function of electrical conductivity, radius and thermal conductivity. As a result, the non-linear temperature response of RF induced heating can be adequately expressed mathematically as a function of electrical conductivity, radius and thermal conductivity. Hence, thermal conductivity accounts for some of the previously unexplained variance. Furthermore, the addition of this variable into the mathematical model substantially simplifies the equations and, as such, it is expected that this will permit improved prediction of RF ablation induced temperatures in clinical practice.

Catheter Ablation↗

Water modeled signal removal and data quantification in localized MR spectroscopy using a time-scale postacquistion method.

We have previously shown the continuous wavelet transform (CWT), a signal-processing tool, which is based upon an iterative algorithm using a lorentzian signal model, to be useful as a postacquisition water suppression technique. To further exploit this tool we show its usefulness in accurately quantifying the signal metabolites after water removal. However, due to the static field inhomogeneities, eddy currents, and "radiation damping," the water signal and the metabolites may no longer have a lorentzian lineshape. Therefore, another signal model must be used. As the CWT is a flexible method, we have developed a new algorithm using a gaussian model and found that it fits the signal components, especially the water resonance, better than the lorentzian model in most cases. A new framework, which uses the two models, is proposed. The framework iteratively extracts each resonance, starting by the water peak, from the raw signal and adjusts its envelope to both the lorentzian and the gaussian models. The model giving the best fit is selected. As a consequence, the small signals originating from metabolites when selecting, removing, and quantifying the dominant water resonance from the raw time domain signal are preserved and an accurate estimation of their concentrations is obtained. This is demonstrated by analyzing (1H) magnetic resonance spectroscopy unsuppressed water data collected from a phantom with known concentrations at two different field strengths and data collected from normal volunteers using two different localization methods.

Artifacts↗

1H spectroscopy without solvent suppression: characterization of signal modulations at short echo times.

While most proton ((1)H) spectra acquired in vivo utilize selective suppression of the solvent signal for more sensitive detection of signals from the dilute metabolites, recent reports have demonstrated the feasibility and advantages of collecting in vivo data without solvent attenuation. When these acquisitions are performed at short echo times, the presence of frequency modulations of the water resonance may become an obstacle to the identification and quantitation of metabolite resonances. The present report addresses the characteristics, origin, and elimination of these sidebands. Sideband amplitudes were measured as a function of delay time between gradient pulse and data collection, as a function of gradient pulse amplitude, and as a function of spatial location of the sample for each of the three orthogonal gradient sets. Acoustic acquisitions were performed to demonstrate the correlation between mechanical vibration resonances and the frequencies of MR sidebands. A mathematical framework is developed and compared with the experimental results. This derivation is based on the theory that these frequency modulations are induced by magnetic field fluctuations generated by the transient oscillations of gradient coils.

Acoustics↗

The evaluation of human breast lesions with magnetic resonance imaging and proton magnetic resonance spectroscopy.

PURPOSE: MR spectroscopy (MRS) assists in lesion characterization and diagnosis when combined with magnetic resonance imaging (MRI). Cancerous lesions demonstrate elevated composite choline levels arising from increased cellular proliferation. Our study investigated if MR spectroscopy of the breast would be useful for characterizing benign and malignant lesions. MATERIALS AND METHODS: Single voxel proton MR spectroscopy (MRS) was acquired as part of an MR imaging protocol in 38 patients referred upon surgical consultation. The MR spectra were read independently in a blinded fashion without the MR images by three spectroscopists. The MRI exam was interpreted in two settings: (a) as a clinical exam with detailed histories and results from previous imaging studies such as mammography or ultrasound included and (b) as a blinded study without prior histories or imaging results. RESULTS: Elevated choline levels were demonstrated by MRS in 19 of the 23 confirmed cancer patients. The sensitivity and specificity for determining malignancy from benign breast disease with MRS alone were 83 and 87%, respectively, while a blinded MRI review reported 95 and 86%, respectively. CONCLUSIONS: Proton MR spectroscopy provides a noninvasive, biochemical measure of metabolism. The technique can be performed in less than 10 min as part of an MRI examination. MRI in combination with MRS may improve the specificity of breast MR and thereby, influence patient treatment options. This may be particularly true with less experienced breast MRI readers. In exams where MRI and MRS agree, the additional confidence measure provided by MRS may influence the course of treatment.

Adolescent↗

In vivo near-infrared fluorescence imaging of osteoblastic activity.

In vertebrates, the development and integrity of the skeleton requires hydroxyapatite (HA) deposition by osteoblasts. HA deposition is also a marker of, or a participant in, processes as diverse as cancer and atherosclerosis. At present, sites of osteoblastic activity can only be imaged in vivo using gamma-emitting radioisotopes. The scan times required are long, and the resultant radioscintigraphic images suffer from relatively low resolution. We have synthesized a near-infrared (NIR) fluorescent bisphosphonate derivative that exhibits rapid and specific binding to HA in vitro and in vivo. We demonstrate NIR light-based detection of osteoblastic activity in the living animal, and discuss how this technology can be used to study skeletal development, osteoblastic metastasis, coronary atherosclerosis, and other human diseases.

Animals↗

Radio-frequency thermal ablation with NaCl solution injection: effect of electrical conductivity on tissue heating and coagulation-phantom and porcine liver study.

PURPOSE: To characterize the effects of NaCl concentration on tissue electrical conductivity, radio-frequency (RF) deposition, and heating in phantoms and optimize adjunctive NaCl solution injection for RF ablation in an in vivo model. MATERIALS AND METHODS: RF was applied for 12-15 minutes with internally cooled electrodes. For phantom experiments (n = 51), the NaCl concentration in standardized 5% agar was varied (0%-25.0%). A nonlinear simplex optimization strategy was then used in normal porcine liver (n = 44) to determine optimal pre-RF NaCl solution injection parameters (concentration, 0%-38.5%; volume, 0-25 mL). NaCl concentration and tissue conductivity were correlated with RF energy deposition, tissue heating, and induced coagulation. RESULTS: NaCl concentration had significant but nonlinear effects on electrical conductivity, RF deposition, and heating of agar phantoms (P<.01). Progressively greater heating was observed to 5.0% NaCl, with reduced temperatures at higher concentrations. For in vivo liver, NaCl solution volume and concentration significantly influenced both tissue heating and coagulation (P<.001). Maximum heating 20 mm from the electrode (102.9 degrees C +/- 4.3 [SD]) and coagulation (7.1 cm +/- 1.1) occurred with injection of 6 mL of 38.5% (saturated) NaCl solution. CONCLUSION: Injection of NaCl solution before RF ablation can increase energy deposition, tissue heating, and induced coagulation, which will likely benefit clinical RF ablation. In normal well-perfused liver, maximum coagulation (7.0 cm) occurs with injection of small volumes of saturated NaCl solution.

Animals↗

Exposure to lead appears to selectively alter metabolism of cortical gray matter.

OBJECTIVE: The effects of lead poisoning on the development of children have been examined primarily in the context of behavioral and neuropsychological studies. The purpose of this study was to examine the in vivo use of magnetic resonance spectroscopy (MRS) for the evaluation of the neurotoxic effects of lead on the nervous system. MRS has the ability to monitor brain metabolism by detecting a number of neurochemicals among which is N-acetylaspartate, a metabolite shown to decrease in processes that involve neuronal loss. METHODS: In the present study we evaluated the metabolism of gray and white matter of frontal cortex using MRS in individuals with elevated blood lead levels and compared the results with those obtained on nonlead-exposed controls. RESULTS: Although all of the participants had normal MRI examinations of the brain, the lead-exposed individuals exhibited a significant reduction in the N-acetylaspartate/creatine and phosphocreatine ratios in frontal gray matter compared with the nonlead-exposed controls. CONCLUSIONS: The findings of this study suggest that lead has an effect on brain metabolites as detected by MRS in vivo. More specifically, we have found statistically significant reduced levels of brain metabolites in gray but not white matter in lead-exposed individuals. These results imply that MRS is able to detect metabolic abnormalities in individuals with lead poisoning.

Adolescent↗

Magnetization transfer imaging and proton MR spectroscopy in the evaluation of axonal injury: correlation with clinical outcome after traumatic brain injury.

BACKGROUND AND PURPOSE: Current imaging does not permit quantification of neural injury after traumatic brain injury (TBI) and therefore limits both the development of new treatments and the appropriate counseling of patients concerning prognosis. We evaluated the utility of magnetization transfer ratio (MTR) and proton MR spectroscopy in identifying patients with neuronal injury after TBI. METHODS: Thirty patients with TBI (21-77 years old; mean age, 42 years; admission Glasgow Coma Scale (GOS) scores 3-15; mean score, 11) were studied on a 1.5-T system with magnetization transfer imaging and MR spectroscopy of the splenium. Magnetization transfer imaging was also performed in the brain stem in all patients, and other areas of the brain were sampled in one patient. The splenium of the corpus callosum and brain stem were studied because these are often affected by diffuse axonal injury. Scans were obtained 2 to 1129 days after injury (median, 41 days). MTR was considered abnormal if it was more than 2 SD below normal. Proton MR spectroscopy was used to calculate the N-acetylaspartate (NAA)/creatine (Cr) ratio. GOS was determined at least 3 months after injury. RESULTS: In 10 patients with a GOS of 1 to 4, the mean NAA/Cr was 1.24 +/- 0.28; two of these patients had abnormal MTR in normal-appearing white matter (NAWM). In 20 patients with a GOS of 5, the mean NAA/Cr was 1.53 +/- 0.37 (P < .05); four of these patients had abnormal MTR in NAWM. MTR abnormalities in NAWM were identified in six patients, but these changes did not correlate with GOS or MR spectroscopy changes. CONCLUSION: MTR and MR spectroscopy can quantify damage after TBI, and NAA levels may be a sensitive indicator of the neuronal damage that results in a worse clinical outcome.

Aspartic Acid↗

Transient MRI enhancement in a patient with seizures and previously resected glioma: use of MRS.

A 35-year-old man presented with partial seizures 10 years after resection of a left-sided glioblastoma multiforme. At the old operative site MRI demonstrated extensive cortical and white matter gadolinium enhancement, and PET showed hypermetabolism. Biopsy of the area was postponed when MRS showed a normal biochemical spectrum. MRI and PET abnormalities resolved after control of the seizures. MRS is noninvasive and can provide essential information in the management of patients with seizures and previously treated cerebral neoplasms.

Adult↗

Proton magnetic resonance spectroscopy in the frontal and temporal lobes of neuroleptic naive patients with schizophrenia.

Studies with proton magnetic resonance spectroscopy (MRS) have reported abnormalities in N-acetyl-aspartate (NAA), amino acids (AA) and choline (Cho) to creatine (Cr) ratios associated with schizophrenia. We report data on the three ratios in a sample of 18 neuroleptic naive patients with first-episode schizophrenia (eight studied in the dorsolateral prefrontal and 10 in the midtemporal lobe) and 24 healthy controls (14 studied in prefrontal and 10 in midtemporal lobes). Frontal lobe proton spectra were acquired with the stimulated-echo acquisition mode (STEAM) pulse sequence (echo time 21 ms, repetition time 2 s). Temporal lobe proton spectra were acquired with the point-resolved spectroscopy (PRESS) pulse sequence (echo time 16-21 ms, repetition time 2 s). Upon comparison with normal controls, NAA/Cr ratios were reduced in patients both for the frontal and the temporal lobe. By contrast, Cho/Cr ratios were slightly elevated in frontal and reduced in temporal lobes; whereas, AA/Cr ratios were normal in frontal and markedly increased in the temporal lobe. The reduced NAA/Cr ratios suggest lower neuronal viability in patients and is consistent with findings of reduced brain volume in both frontal and temporal regions.

Adult↗

Pulmonary perfusion: respiratory-triggered three-dimensional MR imaging with arterial spin tagging--preliminary results in healthy volunteers.

The authors used a spin-tagging method of magnetic resonance perfusion imaging to measure pulmonary perfusion in eight healthy volunteers with use of a respiratory-triggered three-dimensional pulse sequence. The average signal intensity (SI) decrease upon arterial labeling was 24%. The perfusion SI increased by 21% after exercise (P = .02). Focal blood flow abnormalities were observed in a patient with chronic obstructive pulmonary disease.

Adult↗

Bilateral imaging using separate interleaved 3D volumes and dynamically switched multiple receive coil arrays.

Multiple receive coil arrays are often designed for unilateral imaging of anatomy having bilateral symmetry. A technique is described for extending the utility of such arrays to simultaneously image both bilaterally symmetric anatomical features. A separate, complete multiple receive coil array is placed at each location. Two separate, noncontiguous 3D volumes are then acquired, one at each location, in an interleaved fashion. High-impedance blocking networks are alternately activated and deactivated to minimize coupling between the arrays. It is demonstrated that there is no degradation in image quality when compared to a unilateral exam. A general method for analyzing the interactions between separate multiple coil arrays is presented.

Breast↗

Fast imaging of phosphocreatine using a RARE pulse sequence.

A technique is described for acquiring phosphocreatine (PCr) images of skeletal muscle using a rapid acquisition with relaxation enhancement (RARE) pulse sequence. All of the phosphorus metabolites other than PCr are forced to dephase within the first few echoes, whereas the Carr-Purcell Meiboom-Gill (CPMG) pulse sequence maintains a high PCr signal long enough to acquire 64 echoes in a single shot. Axial PCr images of a human forearm with a signal-to-noise ratio of 9 were acquired in 2 min. The effect of the refocusing pulse section profile on the ratio of desired to undesired metabolite signal is demonstrated.

Forearm↗

High-field proton magnetic resonance spectroscopy of a swine model for axonal injury.

A miniature swine model for diffuse brain injury has recently been developed that replicates the inertial loading conditions associated with rotational acceleration during automotive accidents. The swine model induces diffuse axonal pathology without macroscopic injury such as contusions and hematomas, thus affording a unique opportunity to study axonal injury with noninvasive techniques such as magnetic resonance imaging (MRI) and spectroscopy (MRS). In the present study, we evaluated this diffuse injury model with proton MRS, in vivo, using a high-field (4.0-T) MR scanner, since MRS has been demonstrated as a sensitive probe for detecting neurochemical abnormalities. Our study examined a region of the swine brain at timepoints before and after brain injury. Spectroscopic results indicate that N-acetylaspartate/creatine is diminished by at least 20% in regions of confirmed axonal pathology, whereas conventional MRI did not detect any abnormalities. These findings suggest that MRS has high sensitivity in diagnosing microscopic pathology following diffuse brain injury.

Animals↗

Magnetic resonance spectroscopy of diffuse brain trauma in the pig.

The acute metabolic events linked to the evolution of selective axonal pathology in the white matter following diffuse brain injury have not previously been evaluated due to the paucity of relevant experimental models. Here, we utilized a new model of inertial brain injury in the pig that selectively damages axons in the white matter, and applied proton and phosphorous magnetic resonance spectroscopy (MRS) to noninvasively monitor the temporal course of metabolic changes following trauma. Evaluating four pigs with MRS prior to injury, within 1 h and 3 and 7 days postinjury, we found that widespread axonal injury was produced in the absence of changes in pH, PCr/Pi, or the concentrations of ATP, and lactate. However, we did observe an acute 60% loss of intracellular Mg2+ levels, which gradually resolved by 7 days postinjury. In addition, we found that the levels of the neuron marker, N-acetylaspartate (NAA), acutely dropped 20% and remained persistently decreased for at least 7 days postinjury. Moreover, the changes in Mg2+ and NAA were found with MRS in the absence of abnormalities with conventional magnetic resonance imaging (MRI). These results show that (1) profound alterations in intracellular metabolism occur acutely following diffuse axonal pathology in the white matter, but in the absence of indicators of ischemia, and (2) axonal pathology may be evaluated with high sensitivity utilizing noninvasive MRS techniques.

Adenosine Triphosphate↗