Ionization collection efficiencies of some ionization chambers in pulsed and continuous radiation beams.

The most commonly used method of calibrating high-energy photon or electron beams consists in converting cavity ionization to dose by the application of the appropriate Clambda or CE multipled by the 60Co correction factor. The correct interpretation of calibration data for pulsed photon or electron beams requires a knowledge of the charge collection efficiencies of the ionization chambers used. The results are presented of efficiency measurements for both pulsed and continuous beams made with these chambers: 0.6-cm3 Farmer, 0.5-cm3 Spokas, 3-cm3 Shonka, 1-cm3 PTW, and 1-cm3 Memorial pancake. The dependence of collection efficiency on collection voltage, dose rate, and dose per pulse is demonstrated. These results are shown to agree with Boag's formulas for collection efficiency. Attention is drawn to the fact that several kinds of dosimeters provide only minimal collection voltages for efficient collection of charge at high dose rates, especially in Linac electron beams. It is recommended to check the collection efficiency of chambers which are to be used at high dose rates, and a simple method for this purpose is described.

Cobalt Radioisotopes↗

Comparison of ion chamber and TLD dosimetry in mammography.

An ionization chamber method has been developed to measure exposure vs depth in a uniform BR 12 "average breast" phantom. It employs a Memorial mammography chamber for exit exposure measurements; resulting data is then corrected for backscatter as well as for the exceptionally thin window of this chamber. A careful comparison has then been made with relative exposure vs depth curves obtained using TLD at several mammography beam qualities, for identical exposure factors and SSD values. Use of a correction for residual and background TL signals significantly improved agreement between TLD and ion chamber curves in the 28 to 35 kVp/0.03 mm Mo range of beam quality. Agreement was within +/- 5% for the Mo target tube, but TLD readings were 4%--8% higher than ion chamber values for the W/Mo target tube. At Xeromammography energies (45 kVp/1.6 mm Al), corrected TLD curve readings were 6% higher at depth than ion chamber curve values. TLD meaurements with 28 to 35 kVp/0.03 mm Mo beams tend to underestimate dosage to the midbreast parenchyma. For example, in a 5 cm "average breast", the underestimation ranges from 2%--10% for corrected, 10%--16% for uncorrected TLD readings.

Female↗

Measurements of diagnostic x-ray backscatter by a novel ion chamber method.

There is a major gap in backscatter information for diagnostic x-ray beams. Such information is increasingly needed for dose measurements and calculations, as well as for designing devices and techniques. We have therefore carried out measurements on both low Z materials and metals, using an ion chamber method designed specifically for the purpose. Lucite and two D.R. White tissue substitutes were studied extensively (BR 12 "average breast" and MS 11 "water"). Measured percent backscatter (BS) was greatest for Lucite and least for MS 11, with BR 12 in between. Backscatter buildup is rapid: 50% of full backscatter is achieved with 6 mm thickness for all three materials using mammographic beams and with about 12 mm using general diagnostic beams. A simple relationship between BS and field area permits close estimates of BS values for fields for which measured data is not available. Among metals tested, copper exhibited greatest backscatter (39% BS maximum), aluminum least, and lead in between--information of potential importance in cassette design and similar applications.

Mammography↗