Wick technique: reference method for implanted glucose sensors.

The control of function of experimentally implanted glucose sensors needs an independent reference method. Employing saline-impregnated cotton threads, an implanted wick-technique was adopted in dogs to obtain analytical specimen from the subcutaneous interstitial fluid compartment. By measuring the contents of potassium, calcium, and hemoglobin, the centrifuged wick fluid was validated to contain the interstitial concentrations of solutes after an equilibration time of approximately 15 min. Between 2 and 25 mmol/L, the steady state subcutaneous glucose concentration is nearly identical to circulating glycemia. Slow alterations, as during an oral glucose tolerance test, (OGTT) are well paralleled by the levels in the wick fluid. During alterations, however, a distinct delay is observed. The wick-based glucose levels are mirrored by the output of electrochemical sensors implanted at the same site. This method may be used in checking implanted sensors that can otherwise not be calibrated in situ.

Animals

The GOD-H2O2-electrode as an approach to implantable glucose sensors.

The long-term function of glucose sensors under in-vivo conditions is the first prerequisite in the development of glucose-controlled insulin infusion systems. Amperometric enzyme glucose sensors measuring H2O2 from the enzymatic glucose oxidation are defeated to certain poisoning effects of the electrochemical system and to alterations of the diffusional properties, both resulting in unpredictable changes of the sensor signal. To interpret the signal of subcutaneously implanted sensors after reaching a certain balance of the altering processes, the wick-technique has been established as an independent reference method applicable in the interstitial fluid. Based on the comparison of the wick-glucose concentration and the circulating plasma glucose concentration the in vivo-calibration of the sensor current according to plasma glucose concentration is proven.

Animals

Assessment of subcutaneous glucose concentration: validation of the wick technique as a reference for implanted electrochemical sensors in normal and diabetic dogs.

Employing saline-impregnated cotton threads, an implanted-wick technique was adopted in dogs to obtain specimen from the subcutaneous interstitial compartment in order to estimate its glucose concentration. By measuring the protein, potassium and haemoglobin contents, the centrifuged wick fluid was shown to contain the interstitial concentration of solutes after an equilibration time of approximately 15 min. In normal and in diabetic animals the steady state subcutaneous glucose concentration was almost identical to the circulating glucose level when ranged between 2 and 25 mmol/l. Slow alterations in the circulating glucose profile such as those which appear during an oral glucose tolerance test are closely mirrored by the respective levels in the wick fluid. Fast alterations, however, show deviations. The wick-based glucose levels are well paralleled by the current of Clark type glucose oxidase sensors implanted at the same site. Since, on the basis of in vitro calibrations the sensor outputs have only indicated apparent tissue glucose concentrations of between 70 and 90% of glycaemia, another reference is needed for calibration. Under steady state conditions, the wick method, and on this basis in routine measurements the blood glucose concentration, may be recommended as a reference of implanted sensors which can otherwise not be calibrated in situ.

Animals