Multiple-wavelength powder diffraction using imaging plates at the Australian National Beamline.

The Australian powder diffractometer at the Photon Factory is capable of recording multiple powder-diffraction scans in less than 5 min per pattern using imaging plates in Debye-Scherrer geometry. This, coupled with incrementing the X-ray beam energy in suitably small steps (down to approximately 2 eV) between exposures, allows fast collection of anomalous diffraction data. Data collected from a copper oxide-based superconductor at energies near the Cu K-absorption edge are presented, along with an account of the technique used to extract multiple-exposure powder-diffraction data from imaging plates.

Journal Article↗

Focusing monochromator and imaging-plate camera for grazing-incidence diffraction studies of thin films.

A multiple-imaging-plate detector system and focusing monochromator have been developed and successfully applied to the time-resolved study of phase transitions in Langmuir-Blodgett films by grazing-incidence X-ray diffraction (GIXD). The monochromator described here combines fixed-exit-beam height with sagittal focusing of the second crystal. The design is similar to that of Matsushita et al. [Matsushita, Ishikawa & Oyanagi (1986). Nucl. Instrum. Methods, A246, 377-379], with the exception that the motion of the first crystal is achieved via a computer-controlled X-Y translation table rather than a set of cams. The second crystal is a ribbed Si(111) wafer mounted in a four-point bending mechanism. The first reported application of imaging plates to a GIXD study was carried out by our group and proved to be very successful in the determination of thin-film structure [Foran, Peng, Steitz, Barnes & Gentle (1996). Langmuir, 12, 774-777]. To extend the capabilities of this system, an imaging-plate camera was designed and built which can accommodate up to 13 imaging plates (40 x 20 cm) inside the vacuum chamber of the main diffractometer at the Australian Beamline at the Photon Factory.

Journal Article↗

An eight-position capillary sample spinning stage for the diffractometer at BL20B at the Photon Factory.

An eight-position capillary sample spinning stage has been developed for use in conjunction with the versatile vacuum diffractometer (BIGDIFF) at BL20B at the Photon Factory. BIGDIFF is often used in its powder diffraction mode using powders mounted in capillaries and up to eight imaging plates to record the diffraction pattern from the sample. Using the multiple spinning stage a number of diffraction patterns can be recorded on the imaging plates if the imaging-plate cassette is moved behind the Weissenberg screen to a new position after exposure of the sample to the beam. Not only is this system more efficient in terms of time saved in the pumping-down process, but also it has the advantage of allowing the diffraction patterns of standards to be recorded, thereby calibrating both the angle scale of the diffractometer and the intensity scales of the imaging plates absolutely.

Journal Article↗

Time-resolved grazing-incidence diffraction studies of thin films using an imaging-plate camera and focusing monochromator.

A multiple imaging-plate (IP) detector system and focusing monochromator have been developed and successfully applied to the time-resolved study of phase transitions in Langmuir-Blodgett (LB) films by grazing-incidence X-ray diffraction (GIXD). The first reported application of imaging plates to a GIXD study was carried out by our group and proved to be very successful in the determination of thin-film structure [Foran, Peng, Steitz, Barnes & Gentle (1996). Langmuir, 12, 774-777]. To extend the capabilities of this system, an IP camera was designed and built which can accommodate up to 13 IPs (40 x 20 cm) inside the vacuum chamber of the main diffractometer at the Australian Beamline at the Photon Factory. The camera allows the enclosed IPs to be successively exposed and stored inside the diffractometer for later scanning. The focusing monochromator employed in this technique combines fixed exit-beam height with sagittal focusing of the second crystal and delivers a gain in flux of >/=20 times when measured through a 0.1 x 0.1 mm aperture. The utility of the system incorporating the IP camera and the focusing monochromator has been demonstrated through the study of temperature-dependent phase transitions in LB films of metal fatty acids.

Journal Article↗

Protein Crystal Diffraction Patterns Using a Capillary-Focused Synchrotron X-ray Beam.

A paraboloidally tapered glass monocapillary was used to focus an 8 keV monochromated synchrotron bending-magnet X-ray beam into a 40 (+/-5) mum focal spot located 45 (+/-5) mm from the exit of the capillary. This focal spot had a measured intensity gain of 120 (+/-10) times the intensity present in an equivalent cross section of the unfocused beam from the monochromator. This focused beam was used to obtain oscillation diffraction patterns on image plates from a hen egg-white lysozyme protein crystal in two distinct geometries: one with the specimen crystal at the capillary exit and the other with the crystal at the beam focus. In the first geometry, focused Bragg reflections were observed at the focal plane. In the second geometry, diverging Bragg reflections of high intensity from a small crystal volume were observed. Image-plate diffraction patterns for these two geometries were compared with exposures with equivalent integrated diffracted intensities obtained using a 100 x 100 mum unfocused X-ray beam with the same crystal. The use of the focused beam resulted in a reduction in the exposure time required to produce equivalent patterns by a factor of between 70 and 100.